DiBO n.v. 55
7. Malfunction table
At a possible malfunction one can consult the table mentioned below and if you obtain on this basis no solution, we
advise to contact a DiBO technician and/or a recognized DiBO representative.
Malfunction
Cause
Solution
Machine does not start
Electrical supply not connected
Connect the electrical supply
Net fuse defect
Check net fuse
Main switch on “0”
Put main switch on “1”
Rest malfunctions
Consult an expert
No water pressure
To few water inlet
Repair water inlet
Filter stuffed-up
&OHDQUHSODFH¿OWHUFDUWULGJH
Instable and to weak pressure
Air in water supply (leaks in water
supply)
Put machine completely without
power! Repair leaks in supply.
Nozzle or lance stuffed-up or worn-
out.
Clean or replace
Pressure regulator defect
Consult an expert
Rest malfunctions
Consult an expert
Water in product tank
1RQUHWXUQYDOYHLQ¿OWHUGHIHFW
5HSODFHVXFWLRQ¿OWHU
No additions of products
Suction pipe
Repair suction pipe
6XFWLRQ¿OWHUVWXIIHGXS
&OHDQVXFWLRQ¿OWHU
Product tank empty
5H¿OORUUHSODFHWDQN
Spray pressure to high
Lower spray pressure
HP pump pulse
Leak or congestion in supply conduit
Clean/replace/repair
To much air present
De-aeration of cleaner