of the shaft, adjusting the flame dimensions to the minimum without letting it go out, and
thus, allowing the thermopar to have enough heat so as to block the tap. After adjusting the
minimum, wait for a couple of minutes to make sure that the flame doesn’t go out.
In case there’s a tap malfunction, it should be replaced and there should not be any attempt to
oil it.
All equipments have to be analyzed regularly, at least once per year. In order to assure a
longer product life, this maintenance has to be carried out by accredited technicians.
7.
TYPES OF GAS, INJECTORS AND CATEGORY
TYPE GÁS
PRESSURE (mbar)
INJECTOR
CATEGORY
G-20 (GAS NATURAL)
20
130
2H/2E+
G-25 (GAS NATURAL)
25
130
2L
G-30, G-31 (G.P.L.)
28-30/37
90
3+
G-30 (G.P.L.)
50
80
3B/P
G-31 (G.P.L.)
50
82
I3P
8.
TECHNICAL DATA
PPGF 600 / 600 CRD-T
Qn
V/M
G20
5, 8 KW
0,62 m
3
/h
G25
5, 8 KW
0,70 m
3
/h
G30
5, 8 KW
460 g/h
G31
5, 8 KW
460 g/h
PPGF 800 / 800 CRD-T
Qn
V/M
G20
8,7 KW
0,93 m
3
/h
G25
8,7 KW
1, 05 m
3
/h
G30
8,7 KW
690 g/h
G31
8,7 KW
690 g/h
PPGF 600 / PPGF 600 CRD-T / PPGF 800 / PPGF 800 CRD-T
Q. TUBULAR
REDUCED HEAT FLOW
G20 / G25 / G30 / G31
2,1 kW
8 GB