Dia-Clean Digital Video Microscope - e
11
With the IBC cleaner 80% of cases the cleaning is carried out without problems, there is a 20% of cases where
cleaning with the IBC Cleaner won’t met the criteria if so try to pull out the plug from the mating adapter
and clean it wet (see CLEANING AND INSPECTING FERRULE ENDFACE USING A ISOPROPYL ALCOHOL) If after
repeated cleaning the connector still does not meet the acceptance criteria, the connector must be replaced
or re-polishing.
Applications
Fiber network panels and assemblies
Cleans harsh environment 2.5mm or 1.25mm based connector systems
Cable assembly production facility
Testing laboratories
Servers, switches, routers and interfaces with E-2000, SC, FC, ST and F-3000
Do NOT use this cleaner when the cloth is empty. This may can cause damage to the connector.
The dust cap should be closed at all times when device is not in use.
7
CLEANING THE CONNECTOR FRONT FACE USING „IBC CLEANER“