E100301X rev5
21/02/14
31. PROGRAMS
To enter in the program area, please follow the
instruction given in the previous paragraph.
When the display shows “PROGRAMS
▲▼
”,
press ENTER
◄┘
.
Scroll down the programs with the key
▲
and
▼
until it is displayed the name of the program that
you want to modify.
When the wished program is displayed (in our
example the number 3), press ENTER
◄┘
. In this
way it is possible to enter in the program n. 3
parameters modification. The parameters list can
be scrolled up and down using the keys
▲
and
▼
.
From this point use the keys as explained below:
- The
keys
”
▲▼
”, to scroll the available
parameters.
- The
key
“ENTER
◄┘
” to enter in a
program and modify it.
-
The keys ”
▲▼
” to modify the value while
it is flashing.
- The key “ENTER
◄┘
” to confirm the
displayed value.
- The key “
◄
►
” to change the cursor
position to write the PROGRAM NAME.
Here below the program which can be modified
and their possible values.
PROGRAM NAME
Program description displayed during the program
selection and execution. It can be maximum 16
character long.
PROGRAM TYPE
This parameter is used to make the program
works in an automatic way (deciding the residual
humidity at the end of the cycle) or in a traditional
way (deciding the cycle length). The two
parameters are:
- HUMIDITY
- TIME
RESIDUAL HUMIDITY AT THE CICLE END
(only programs “WITH RESIDUAL HUMIDITY”)
Select the value of the residual humidity at the
end of the cycle, once this value is reached the
cycle is ended:
- IRON
DRY
- DRY
- EXTRA
DRY
WDT T SET
(only programs “WITH RESIDUAL HUMIDITY”)
In this area can be fixed the safety time for the
program stop and the set point temperature for
the automatic cycle.
-
DRYING TIME OUT: 1’ ÷ 120’
-
TEMPERATURE: 0°C ÷ 90°C
N. STEP
(only programs “TIME”)
A number of heating steps (or cooling steps) can
be set:
-
1 ÷ 10
STEP 1
(only programs “TIME”)
For each step composing the cycle, it is possible
to decide the drying temperature and the step
length:
-
TIME: 1’ ÷ 120’
-
TEMPERATURE: 0°C ÷ 90°C
STEP 2 … 10
For each step composing the cycle, it is possible
to decide the drying temperature and the step
length:
-
TIME: 1’ ÷ 120’
-
TEMPERATURE: 0°C ÷ 90°C
COOLING TIME
It corresponds to the length of the cooling cycle at
the end of the drying cycle. This time is
automatically reduced if the set point cooling
temperature is reached before the end of the
cycle:
-
0’ ÷ 30’
COOLING TEMPERATURE SET POINT
It is the cooling temperature which determine the
end of the drying program. If the cooling time
elapse before the temperature is reached, the
program end however.
- 0°C
÷
90°C
REVERSING DRUM
(with machine with reversing options)
In case the machine is equipped with a reversing
option, this function can be excluded from the
program.
If the parameter “WITHOUT” is selected, the drum
turn always in the same direction (right).
- WITH
- WITHOUT
DRUM RIGHT ROTATION TIME
(machines and programs WITH REVERSING
DRUM)
It is the drum clockwise turning time:
0” ÷ 5’
DRUM STOP TIME
(machines and programs WITH REVERSING
DRUM)
It is the drum rotation pause:
1” ÷ 5’
DRUM LEFT ROTATION TIME
(machines and programs WITH REVERSING
DRUM)
It is the drum counterclockwise turning time: