Elektra CPU User Manual V1.00
Page 52
10.3.2 PAGE 1: AUTO CALIBRATION REGISTERS
Page 1, Base + 12
Read/Write
EEPROM / TrimDAC Data Register
Bit
No.
7 6 5 4 3 2 1 0
Name
D7 D6 D5 D4 D3 D2 D1 D0
D7-0
Calibration data to be read or written to the EEPROM and/or TrimDAC.
During EEPROM or TrimDAC write operations, the data written to this register will be
written to the selected device.
During EEPROM read operations this register contains the data to be read from the
EEPROM and is valid after EEBUSY = 0.
The TrimDAC data cannot be read back.
Page 1, Base + 13
Read/Write
EEPROM / TrimDAC Address Register
Bit
No.
7 6 5 4 3 2 1 0
Name X A6 A5 A4 A3 A2 A1 A0
A6-A0
EEPROM / TrimDAC address.
The EEPROM recognizes address 0 – 127 using address bits A6 – A0. The
TrimDAC only recognizes addresses 0 – 7 using bits A2 – A0. In each case
remaining address bits will be ignored.