pg. 1
8
Error Codes Cont…
Problem
Possible Cause
Solution
E3, Err-1003, Err-103 =
Control valve motor ran too
long and was unable to find
the next cycle position and
stalled
Motor failure during a
regeneration
Check motor connections. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds and
then reconnect.
Foreign material built up
on piston and stack
assemblies creating
friction and drag enough
to time out motor
Replace piston and seal/stack assemblies. Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect.
Drive bracket not snapped
in properly that reduction
gears and drive gear do
not interface
Snap drive bracket in properly. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds and
then reconnect.
E4, Err-1004, Err-104 =
Control valve motor ran too
long and timed out trying to
reach home position
Drive bracket not snapped
in properly that reduction
gears and drive gear do
not interface
Snap drive bracket in properly. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds and
then reconnect.
Summary of Contents for Reliant DRS4-EM-15