background image

1. INTRODUCTION

This user and maintenance manual will set out the guidelines and proce-

dures that must be followed by those operating this equipment in order to 

guarantee:

• Operators’ safety

• Correct use of the machine 

• Optimum performance 

IT IS NECESSARY THAT THE AUTHORIZED PERSON-

NEL AND MACHINE OPERATOR HAVE READ AND 

UNDERSTOOD THE MANUAL BEFORE USING THE 

MACHINE. 

Due to the importance of this information, we recommend that the opera-

tor:

• Always keeps this manual close at hand for easy consultation

• Keeps the manual in a safe place in order to prevent loss or damage

• Asks the manufacturer/supplier for a replacement copy in case of loss or 

damage

• Supplies this manual and the manufacturer’s details together with the 

machine if it is sold to a third party

IF THE PURCHASED VACUUM CLEANER IS DIAMA-

PRO AUTHORIZED, THE TECHNICAL PLATE AT-

TACHED TO THE ENGINE HAS A SERIAL NUMBER 

THAT IS USED FOR REQUESTING A COPY OF THE 

CERTIFICATE IF THIS IS DETERIORATED OR LOST. 

The manufacturer reserves the right to update its products and manuals 

and is not required to provide updated versions of the them. 

2. WARRANTY 

The vacuum cleaners manufactured by DiamaPro have been fully inspect-

ed to guarantee correct electrical, pneumatic and mechanical function. 

The vacuum cleaners are covered by a 12-month warranty.  All defective 

parts of the machine are covered by warranty but this does not include 

parts damaged during shipping, handling or use nor does it cover parts 

damaged by normal wear and tear. 

Repairs can be carried out by an authorized service center or directly by 

DiamaPro. 

To request your warranty service you MUST send a written request to the 

dealer or directly to the manufacturer including the manufacturing details 

that can be found on a plate fitted inside your machine together with a 

copy of the invoice. 

The warranty is valid under the following conditions:

• Improper use of the machine or total or partial failure to comply with the 

contents of this manual

• Any part of the vacuum cleaner is altered or modified in any way

• Incorrect electrical installation

• If the laws in the country of use are not respected

• Inadequate maintenance

• The machine has not undergone routine maintenance as specified in this 

manual

• Use of spare parts that are not produced by DiamaPro or not specifically 

indicated for the model in use 

• Partial or total failure to comply with the instructions given in this manual 

3. UNINTENDED USE

• Never suck up cigarette butts that have not been properly put out and/or 

any other flammable materials 

• Never suck up substances that may explode in contact with the air 

• Never operate in environments where explosive gases and/or gases from 

toxic chemical products are present in the air 

• Check the suitability of the cartridge filter before sucking up toxic sub

-

stances 

• Disconnect from the power outlet before accessing any electrical compo-

nents of the machine 

• Do not modify the machine in any way 

• Do not use the machine in a way that does not comply with the require-

ments of this manual 

4. MACHINE DATA 

4.1 TECHNICAL DATA PLATE

Every DiamaPro machine carries a registration plate showing essential 

details that are necessary when contacting the supplier/manufacturer for 

advice, suggestions or information on spare parts. The following details are 

included on the plate:

• Manufacturer 

• Model

• Supply voltage

• Installed rated power

• CE symbol (built in compliance with Machinery Directive 2006/42/EEC) 

4.2 TESTING

All DiamaPro machines are tested before packaging and delivery in order 

to ensure the correct function of each component. An accurate electrical 

safety test is carried out in compliance with specific electric safety stan

-

dards related to:

• Ground continuity test 

• Insulation resistance test between every phase and the ground

• Dielectric test

• Measurement of dispersed current

• Measurement of power and absorbed current (acceptable difference of 

+/-10% of rated value)

• Measurement of maximum depression and air exhaust values (tolerance 

of +/-15% based on temperature values and humidity of environment) 

• Measurement of maximum air absorption 

4.3 SAFETY DEVICE

The vacuum cleaner has been manufactured in compliance with all legal 

standards for the operator’s safety.

• All metal components are grounded to eliminate shock or electrostatic 

discharge, including the flexible suction hose that is properly grounded. 

Also in this regard the choice of a suitable flexible suction hose allows to 

eliminate this risk on the hose length that goes from the use area to the 

vacuum cleaner. 

• The brakes fitted onto the anterior pivoting casters safely fix the machine 

in its place of use where there may be a risk of movement due to uneven 

floor surfaces or other particular working conditions. 

BEFORE USING THE MACHINE CHECK THAT THE 

MACHINE HAS NOT SUFFERED ANY SHOCKS OR 

DAMAGES DURING THE TRANSPORT  THAT CAN 

AFFECT THE OPERATION OF THE ABOVE DEVICES

5. PERFORMANCE TOLERANCES

The performance of the turbine may vary by 15% based on the tempera-

ture and air humidity. 

The safety valves are calibrated based on the amperage of the turbine. 

6. SAFETY PROVISIONS

• Carefully read the instructions in this manual before starting, using, 

servicing or operating the vacuum cleaner 

• Check that the vacuum cleaner hasn’t been damaged in any way 

• Never turn on the machine if it is faulty or if you suspect it is faulty 

• Check that the switch isn’t worn or damaged 

• Do not approach the suction intake of the machine with unfastened or 

broken garments that could easily be sucked into the machine 

• Check that the filters are present and efficient 

• Make sure that the filters are installed correctly and in full working order, 

always observing the regulations in force in the workplace 

• Do not carry out repairs without the manufacturer’s authorization 

• Never use gasoline, solvents or other flammable liquids for cleaning; 

only proper detergents should be used for cleaning 

• Never move the machine by pulling the power cable or flexible hose

• Never direct the opening of the machine or the flexible tube towards 

people or animals 

• Protect the machine from the rain 

• Check that the machine is connected to a power source with the correct 

voltage indicated on the registration plate 

Summary of Contents for SVX2-A

Page 1: ...OWNER S MANUAL SVX2 A INDUSTRIAL VACUUM USER MAINTENANCE BOOK SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE ...

Page 2: ...th the require ments of this manual 4 MACHINE DATA 4 1 TECHNICAL DATA PLATE Every DiamaPro machine carries a registration plate showing essential details that are necessary when contacting the supplier manufacturer for advice suggestions or information on spare parts The following details are included on the plate Manufacturer Model Supply voltage Installed rated power CE symbol built in complianc...

Page 3: ...INTENANCE Maintenance and cleaning operations must ALWAYS be carried out when the vacuum is turned off and disconnected from the power source No particular measures must be taken for the maintenance cleaning or lubri cation of the suction unit However it is important to remember that correct use and servicing are essential if the safety and efficiency of the vacuum are to be guaranteed To ensure r...

Page 4: ... the quick coupling nozzle mounted on the filter chamber See the accessories sheet 13 USING THE VACUUM CLEANER I 3 Motors switch ON O Switch OFF 14 FILTER REPLACEMENT Before switching ON the vacuum be sure the container is empty 2 Push for forced filters cleaning 1 Disconnect and lift the head 2 Remove the filter s cylindrical steel protection unscrewing the screws on the edge 3 Unscrew the wing n...

Page 5: ...a plastic tubular from which are obtained 20 30 bags of different weights and dimensions Once finished or damaged the tubular must be replaced by a new refill The operations below described must be carried out when machine is turned off 17 BAG REPLACEMENT 1 Cut the Infinity Bag in order to let it open 2 Pull and rotate the re taining pins of the Infinity bag container in order to unfasten them 3 R...

Page 6: ...19 ELECTRIC DIAGRAM 1 TERMINAL 2 ANTI DISORDER 3 SWITCH 0 1 4 MOMENTARY SWITCH NO 5 ELECTRONIC CARD 6 MOTOR 7 VIBRATOR ...

Page 7: ...facturer declares that the technical file of the equipment is kept at This statement will expire automatically for 1 Changes to the equipment 2 Non compliance with instructions contained in the user and maintenance manual SVX2 A 2018 2006 42 CE CE Machinery Directive 2014 35 UE CE Low Voltage Directive 2014 30 UE CE EMC Directive EN ISO 12100 2010 EN 60335 2 69 EN 55014 1 2006 DiamaPro Systems P O...

Page 8: ...DiamaPro Systems P O Box 19946 Charlotte NC 28219 404 834 1162 Dealer s signature and stamp ...

Reviews: