15. TROUBLESHOOTING
You can thus solve any problem that may occur.
Motors do not start.
u
No electrical voltage.
u
Check cables, plugs and socket.
Suction capacity decreases slowly.
u
Filter, nozzle, suction hose or suction pipe may be blocked.
u
Check, clean accessories. Clean filter.
Dust comes out during the vacuuming.
u
Filter has not been fastened correctly or is defective.
u
Check to see if filter is sitting properly; replace if required.
1 - Close the bag with two
distanced bands.
2 - Cut the strip between the
two bands.
3 - Pull the Infinity Bag end to
make a new bag.
16. COLLECTION BAG USE
The dust and the particles are collected in a bag placed in the container under the hopper.
The Infinity Bag system consists in a plastic tubular from which are obtained 20/30 bags of different weights and dimensions.
Once finished or damaged, the tubular must be replaced by a new refill.
The operations below described must be carried out when machine is turned off.
17. BAG REPLACEMENT
1-
Cut the Infinity Bag in
order to let it open.
2-
Pull and rotate the re
-
taining pins of the Infinity
bag container in order to
unfasten them.
3-
Remove the Infinity Bag
container and any waste.
4-
Insert the new Infinity Bag
with the inner part facing
upwards.
5-
Cut and remove the Infinity
Bag closing bands.
7-
Pull the outer part of
the bag to create a new
one.
8-
Insert the container with
the Infinity Bag.
9-
Pull and rotate the retaining
pins and insert them into their
seats.
10-
Pull the bag and place at
the edge the band to create
a new one. If necessary use
two bands.
6-
Keep the inner part
of the bag inside the
container and pull it up
to the lower edge.