Page 1: ...Dialogic BorderNet 4000 Session Border Controller SBC Installation and Deployment Guide December 2013 64 1191 03 www dialogic com...

Page 2: ...ual property licenses with the sale of Dialogic products other than a license to use such product in accordance with intellectual property owned or validly licensed by Dialogic and no such licenses ar...

Page 3: ...tial Release Refer to www dialogic com for product updates and for information about support policies warranty information and service offerings Hardware Limited Warranty Refer to the following Dialog...

Page 4: ...Kit 15 Four Post Rack with Square Holes 16 Four Post Rack with Round Holes 16 7 Installing the BorderNet 4000 SBC 18 MAC address mapping 18 DC power cables 19 AC power cables 20 8 Cabling the BorderN...

Page 5: ...rder DC units 500 mm power feed per power supply An optional 4 M cable is also available for purchase Rack mount kit Dialogic BorderNet 4000 Session Border Controller SBC Installation and Deployment G...

Page 6: ...system software BN4 BSH 1003 BorderNet 4000 SBC HA base hardware AC power supplies AQR1U Rack Mount Kit Optical NICs and base system software BN4 BSS 1000 BorderNet 4000 SBC standalone base hardware D...

Page 7: ...weight for the BorderNet 4000 SBC and the rack mount kit and screws does not include the weight for the shipping box and materials BorderNet 4000 SBC dimensions Caution Ventilation The equipment rack...

Page 8: ...ns of the BorderNet 4000 SBC Power Specifications The following table lists the BorderNet 4000 SBC absolute maximum power specifications Power supply Power component Specification AC Current 10 5 A Vo...

Page 9: ...0 Watts 2xCPU Running Intel Maximum Power Application Typical 25 Degrees C 340 Watts running the same stress test as above Environmental Specifications The following table lists the recommended enviro...

Page 10: ...onnector USB 2 0 RST Reset button Push to reboot Caution Using this button may result in a service interruption M Fault Indicates a major fault warning such as if a component temperature reaches a cri...

Page 11: ...icing when it is installed in a rack with several other similar systems Flashes blue when pressed and turns off when pressed again Can be illuminated remotely from the BorderNet 4000 Management User I...

Page 12: ...BorderNet 4000 SBC includes the following interfaces Interface Description Eth0 Eth1 Eth2 Eth3 10 100 1000 Base T Ethernet interfaces Eth4 Eth5 Eth6 Eth7 Eth8 Eth9 Eth10 Eth11 10 100 1000 Base T Ethe...

Page 13: ...ting the BorderNet 4000 SBC and attaching it to the rack is a two person job If needed use an appropriate lifting device Electrostatic Discharge Protection EDP Use proper ESD protection Electrostatic...

Page 14: ...laser devices Class 1 lasers are not considered to be hazardous All adjustments have been made at the factory prior to shipment of the devices No maintenance or alteration to the device is required Do...

Page 15: ...supply wiring for 48Vdc is minimum 12 AWG Reliable earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direc...

Page 16: ...oles to round holes 1 Refer to the instructions included in the box with the Tool Less Blade Slide Kit to remove the inner channels from the slide kit and attach them to each side of the BorderNet 400...

Page 17: ...ls Torque to 4 5 5 0 kgf cm 3 9 4 3 lbf in 6 Slide the BorderNet 4000 SBC with the attached inner channels into the slide rails and push the BorderNet 4000 SBC all the way into the rack 7 Slide an ear...

Page 18: ...lug Tighten each screw to 10 lbs in torque 2 Connect to a power source If you are installing an AC BorderNet 4000 SBC connect a power cord to the AC connector on the back of the BorderNet 4000 SBC an...

Page 19: ...XX 1 XX XX XX XX XX XX 2 XX XX XX XX XX XX 3 XX XX XX XX XX XX 4 ETH1 motherboard interface ETH2 motherboard interface ETH0 motherboard interface ETH3 motherboard interface MGT motherboard interface D...

Page 20: ...type required Avertissement Ne pas utiliser ni modifier le c ble d alimentation secteur fourni s il ne correspond pas exactement au type requis Warnung Versuchen Sie nicht das mitgelieferte Netzkabel...

Page 21: ...ked to indicate they have been certified by an agency acceptable in your region The power service must be connected through a properly grounded outlet The connector at the product end must be an IEC 3...

Page 22: ...C DPLX optical Multi mode fiber LC duplex connector style For more information refer to the Interfaces section Standalone Configuration The following diagram shows the cabling for a standalone configu...

Page 23: ...following diagram shows the cabling for an HA configuration HA links between two platforms of the HA system have to be a direct connection as follows The HA primary link should connect to a primary li...

Page 24: ...45 Ethernet Interface Pin Assignments RJ 45 Ethernet interfaces use the following pin assignments MDI Media Dependent Interface M Minus P Plus LC OLC DPLX optical The optical transceivers are included...

Page 25: ...r order The following table lists the field replaceable units FRUs and accessories Description Part number AQR1U 650 W AC power supply 306 460 01 AQR1U 650W DC power supply 306 461 01 AQR1U DC power p...

Page 26: ...orm has only a primary role In HA deployments each physical platform can have a designated role as primary or secondary Once you assign the role it cannot be changed unless the system is redeployed Fa...

Page 27: ...onnected to the new Active BorderNet 4000 platform Deploying the BorderNet 4000 SBC Guidelines Deploy the system using a web based interface For HA deployments the primary platform must be deployed fi...

Page 28: ...1 Select Standalone for the Deployment Type 2 Browse to the License File and select it 3 Complete the remaining fields below 4 Click Start Deployment 5 Once the deployment is complete the following s...

Page 29: ...m Management IP address entered in the deployment process Note You must be on the same subnet as that of System Management IP address to access the management interface Refer to the Dialogic BorderNet...

Page 30: ...30 3 Browse to the License File 4 Complete the remaining fields below 5 Click Start Deployment 6 Once the deployment is complete the following screen appears...

Page 31: ...secondary platform After the deployment is complete access the BorderNet 4000 SBC WebUI using the System Management IP address entered in the deployment process Note You must be on the same subnet as...

Page 32: ...es not affect the system configuration data provisioning data In HA configurations existing data on the chosen primary platform is retained In HA configurations both the primary and secondary platform...

Page 33: ...Dialogic BorderNet 4000 SBC Installation and Deployment Guide 33...

Page 34: ...34 2 Click Redeploy to edit the values The following screen appears 3 Complete the fields and click Start...