background image

                                                                                                              

Document No. 

                                                

9100-127-1109-99 Rev A 

                                                                                                     Release Date: Sept 11, 2007 

_____________________________________________________________________ 

 

_____________________________________________________________________________ 

 

Dialight Corporation   1501 Route 34 South    Farmingdale   NJ   07727 

   Tel: 732.919.3119   Fax:732.751.5778   Web: www.dialight.com   

 

Sheet 8 of 14 

 

 

Switch Settings 

 

The microcontroller board has a switch block allowing a number of options to be 
set up as follows:  

 

1 2 3 4 

 
 

ON 

 
 
 
 
 

 ON 

 

 

 

 

 

 

OFF 

 

White 

at 

night 

    Red 

at 

night 

WRED pattern for red   

 

 

50% duty cycle for red 

3

 

Relays pulse while OK   

 

 

Relays static

 

4

 

Relays open on fault 

 

 

 

Relays close on fault 

 

 

 

Note: 

 

1: For both the Red Beacon and White Strobe a fault is indicated after 20 
consecutive faulty flashes. 
 
2: When the fault relays are in pulse mode and their respective light is OK, they 
pulse at 0.5 seconds off and 0.5 seconds on.

 

 

 

 
 
Power Supply to Light Engine Cable 
 

The connection between the power supply and light engine is made by means of 
a shielded multi-way connection cable. 
 
 

 
 
 
 

Summary of Contents for D1RW-C13-006

Page 1: ...ight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com INSTALLATION AND MAINTENANCE MANUAL FOR P N D1RW C13 006 100 230VAC 50 60 Hz 20 000cd w...

Page 2: ...19 Fax 732 751 5778 Web www dialight com Sheet 2 of 14 Contents Page Overview 3 Options 3 Installation and Wiring 6 Switch Settings 8 Operation and Initial Test 10 Lightning Protection 10 Maintenance...

Page 3: ...acon section controlled and monitored by a microcontroller circuit The red beacon type is determined by the top level part number selection either 2 000cd red or 170cd red to meet the Specific require...

Page 4: ...t a default 20FPM or pulse the Sync input with 100 230Vac at the desired flash rate The flashing will synchronize to this pulsing The flashing duty cycle is 50 50 WRED Flashing Mode The Wred flashing...

Page 5: ...____________________________________________________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 5 of 14 Red Beacon L Fig...

Page 6: ...uth Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 6 of 14 Installation and Wiring The Power supply cabinet is designed to mount vertically with power and interconne...

Page 7: ...onnect Dim 0 to live for 30 connect Dim 0 and 1 to live for 10 RED FAULT A Uncommitted solid state relay output 600V 40mA max 20mA continuous RED FAULT B Uncommitted solid state relay output 600V 40mA...

Page 8: ...owing a number of options to be set up as follows 1 2 3 4 ON ON OFF 1 White at night Red at night 2 WRED pattern for red 50 duty cycle for red 3 Relays pulse while OK Relays static 4 Relays open on fa...

Page 9: ...9 of 14 Mounting the Light Engine Dialight recommends the installation of one or more lightning rods near the installed Light Engine The lightning rods should extend a minimum of three feet above the...

Page 10: ...e between the light engine and power supply Do not force the connectors into their mating halves Carefully align the mating halves of the polarized connectors before tightening the locking ring 2 Conn...

Page 11: ...ore installing or working on the light Each driver module has a red indicator light to indicate more than 50VDC present on its output In addition the capacitor board has red indicator lights one for e...

Page 12: ...er or module is faulty Check modules receiving power Replace any faulty driver modules One or more White Strobe layers not lit but all Indicator LED s are lit on driver modules Cable between power sup...

Page 13: ..._________ Dialight Corporation 1501 Route 34 South Farmingdale NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 13 of 14 Table 2 Recommended spare parts user replaceable parts Des...

Page 14: ...e NJ 07727 Tel 732 919 3119 Fax 732 751 5778 Web www dialight com Sheet 14 of 14 Specifications Operating Temperature Range 40 C to 55 C Default flash rate 20 FPM W Red 30FPM Power Supply Specificatio...