IJ3000
IJ3000 Flushing System
5760-029N
Revision B
Installation Instructions
Page 9 of 10
© 2008 Illinois Tool Works Inc. All rights reserved.
Printed in USA
Service Part Kit 5760-029
Specifications
•
Size
o
Height:
6.5”
o
Width: 12.0”
o
Depth:
10.1”
o
Cable clearance: 3” from the rear of the IDS
•
Enclosure
o
Stainless
steel
•
Electrical
o
103VAC-122VAC, 60Hz, 1.0 Amp max.
•
Normal Operating Pressure Range
o
20 psi to 25 psi (approximately)
•
Environment
o
Ambient operating temperature: 40°F to
104°F
o
Operating humidity: 10-90%, non-
condensing
•
Tubing Limitations
o
Maximum horizontal tube length = 100 ft.
o
Maximum vertical tube length (bottom of IDS
to bottom of highest print head) = 20ft.
•
Ink Supply Limitations
o
Maximum height above IDS (top of ink supply
to bottom of IDS) = 8 ft.
o
Maximum distance below IDS (bottom of ink
supply to bottom of IDS) = 8 ft.
o
Maximum horizontal distance between IDS
and supply = 8 ft
•
System Limitations
o
Maximum number of print heads: 16
o
Not compatible with the Dual Tank Diverter
system.
5.50"
1.75"
6.5"
7.50"
2.25"
9.00"
4X 1/4-20
12.00"
TOP VIEW
BOTTOM VIEW
FRONT VIEW