6-16
ID-01 Laser Scanner User’s Manual
EZ Button
EZ Button Modes
The positions are selected by the length of time the button is held. When you want to
select position one, you press and holds the button until one beep is emitted from the
scanner and the 20% LED is turned on. You then release the button to select position one.
If you want to select position two, you continue to hold until you hear two short beeps and
the 40% LED is turned on. Finally, to select position three, you continue to hold the button
until you hear three short beeps and the 60% LED is turned on.
For example, if you want to select the function for position three, you will hear one short
beep, then two short beeps, and finally three short beeps and the 20%, 40%, and 60%
LEDs turn on in progression.
The following table lists the options for the three positions with the default position in bold text:
EZ Button Options
Disabled
: When set to
Disabled
, the button position will have no function associated with
it. The scanner will still respond when the button position is reached.
Read Rate
: Read rate will perform decodes/second and is the same as sending a
<C>
from the terminal. To exit read rate mode, press the EZ Button once quickly.
Calibration
: The calibration routine will be initiated. To abort calibration, press the EZ Button
once quickly.
Save for Power-on
: When when this button position is selected, all scanner settings will
be saved to non-volatile memory to be recalled when scanner is powered-on the next
time. This is the same as sending the
<Z>
in the terminal.
Auto Frame
: Auto Framing will be initiated when this button position is selected. To abort
Definition:
Provides six user-selectable functions for each of the three EZ Button positions.
Serial Cmd:
<
K771,
position 1 mode,position 2 mode,position 3 mode
>
Defaults:
As indicated in the table below.
Options:
As indicated in the table below.
Single Beep
Two Beeps
Three Beeps
0 = Disabled
0 = Disabled
0 = Disabled
1 = Read Rate
1 = Read Rate
1 = Read Rate
2 = Autocalibration
2 = Autocalibration
2 = Autocalibration
3 = Save for Power-on
3 = Save for Power-on
3 = Save for Power-On
4 = Auto Framing
4 = Auto Framing
4 = Auto Framing
5 = Load New Master
5 = Load New Master
5 = Load New Master
6 = Sleep Mode
6 = Sleep Mode
6 = Sleep Mode
Summary of Contents for ID-01
Page 1: ...ID 01 Laser Scanner User s Manual ID 01 User s Manual ...
Page 12: ...xii ID 01 Laser Scanner User s Manual ...
Page 24: ...1 12 ID 01 Laser Scanner User s Manual Configure the Scanner ...
Page 58: ...3 20 ID 01 Laser Scanner User s Manual Intercharacter Delay ...
Page 78: ...4 20 ID 01 Laser Scanner User s Manual Scanner Setup ...
Page 82: ...4 24 ID 01 Laser Scanner User s Manual Laser Setup ...
Page 110: ...5 28 ID 01 Laser Scanner User s Manual Symbol Ratio Mode ...
Page 156: ...8 10 ID 01 Laser Scanner User s Manual Service Message ...
Page 164: ...9 8 ID 01 Laser Scanner User s Manual Auto Frame ...
Page 170: ...10 6 ID 01 Laser Scanner User s Manual Terminal Window Menus ...
Page 190: ...11 20 ID 01 Laser Scanner User s Manual Scanner Status Requests ...
Page 222: ...A 32 ID 01 Laser Scanner User s Manual Glossary of Terms ...