2.4-Input level attenuator & modulation level
Sequence: E + 1 + 4
The display shows:
The digital control of the input level attenuator level allows to modify it between -10dB and +10 dB.
If
"E"
is pressed without changing the output level value, it is returned to
P2
.
The modulation level
is
displayed in digital and analog format in the form of bars.
Under normal modulation conditions, the analog meter moves from the minimum to the maximum of 75 Khz,
indicated by bar Nº. 13. The first symbol “
∗∗∗∗
” indicates 110% modulation.
To modify the modulation level, press the “
↑↑↑↑↓↓↓↓
” keys until the desired value is reached. Once this one is
reached, press
"E"
.
The display will shows:
Press
“1”
to store the new output level,
“2”
to exit without change the current output level and to return
to
P1
.
SECTION 9/7
MOD: 75 K AT: 6dB
∗∗∗∗
∗∗∗∗
∗∗∗∗
STORE LEVEL: 6 dB
1:YES 2:NO: