DFI MDP156 User Manual Download Page 6

6

1

r

e

t

p

a

h

C

INTRODUCTION

User's Manual | 

MDP156

Chapter 1 - Introduction

Specifications

Display

Size/Type

15.6” TFT

Resolution

1920 x 1080

Brightness

400 nits

Contrast 

Ratio

800:1 

Response 

Time

30ms 

Viewing 

Angle

~85~85 (H); ~85~85 (V)

Max Colors

16.2M

Touch

Projected Capacitive Touch

Input/ Output

Input Ports

1 x VGA

1 x HDMI

1 x Audio

1 x USB for Touch

OSD 

Membrane

7 x Control buttons on the rear side

Speaker

2 x 1W Speaker

Power

Specifications

Power Input

12V DC 2.5 mm, with External AC to DC

Adapter (comply with Level VI efficiency

standard)

Power 

Consumption

6.3W typical, normal operation

Mechanical

Specification

Mounting

VESA Mount (75 x 75 mm, 100 x 100 mm, 200 x 100 mm),

VESA Screws M4x4L, (75x75mm, 100 x 100mm) flat head

Dimensions

(W x H x D)

387.8 x 232.9 x 38.45 (mm)

Housing

Back cover white color, plastic casing

OSD Buttons

Menu, Input, Right, Left, Up, Down, Power

Environment

Considerations

Operatin

Temperature

0°C to 50°C

Storage 

Temperature

-10°C to 60°C

Humidity

10%~90% (non-condensing)

LCD Panel 

Lifetime

50, 000 hours

Testing and

Certifications

• IEC 60601-1:2005 + A1:2015 (Ed. 3.1)

• IEC 60601-1-6:2010 + A1:2013 (Ed. 3.1)

• IEC 62366:2007 + A1:2014 (Ed. 1.1)

• ANSI/AAMI ES60601-1:2005/

A1:2012and C1:2009/(R)2012and

A2:2010/(R)2012

• CAN/CSA-C22.2 No.60601-1:14

• EN60601-1-2 (Ed. 4.0)

• EN55032/EN55024, FCC part 15B

• EN60950-1

• RoHS-2, REACH, WEEE compliant

VESA Screws M4x8L, (200 x 100mm) flat head

Summary of Contents for MDP156

Page 1: ...MDP156 15 6 Healthcare Display User s Manual A 605 M 2034...

Page 2: ...CC and DOC Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provid...

Page 3: ...notices for use in the healthcare applications 11 Guidance and manufacturer s declaration electromagnetic emissions 12 Guidance and manufacturer s declaration electromagnetic immunity 12 Recommended s...

Page 4: ...devices even before installing them in your system unit Static electrical discharge can damage computer components without causing any signs of physical damage You must take extra care in han dling t...

Page 5: ...dapter Power Cord VGA Cable HDMI Cable USB Cable for Touch Optional Items Cable Clamp x 3 pcs VESA Desk Stand The main body and accessories in the package may not come similar to the information liste...

Page 6: ...operation Mechanical Specification Mounting VESA Mount 75 x 75 mm 100 x 100 mm 200 x 100 mm VESA Screws M4x4L 75x75mm 100 x 100mm flat head Dimensions W x H x D 387 8 x 232 9 x 38 45 mm Housing Back c...

Page 7: ...to be played through the monitor speak ers 4 HDMI Transmits and protects copyrighted digital video and audio Example An HD tuner to an HD ready TV 5 VGA RGB Transmits video from a PC to a monitor Exam...

Page 8: ...ews to fix the desk stand to VESA holes on the back cover of the device Important The picture is for demonstration purposes only VESA Mount accessories are not supplied by default Connecting Periphera...

Page 9: ...To turn off the device please disconnect the power cord from an electric outlet Important To fully disengage the power please disconnect the input plug from the ac outlet To avoid risk of electric sh...

Page 10: ...cles trains high volt age lines or fluorescent lamps Bad color Color density or tint control may not be adjusted properly See the adjusted value of image Image appears and disappears Input may not be...

Page 11: ...n shall be addressed to the authorized representative For any service or guarantee matters please refer to the ad dresses provided in the separate service or guarantee documents X Important safeguards...

Page 12: ...c dis charge ESD IEC 61000 4 2 8 kV contact 15 kV air 8 kV contact 15 kV air Floors should be wood concrete or ce ramic tile If floors are covered with synthetic material the relative humidity should...

Page 13: ...by an electromagnetic site survey A should be less than the compli ance level in each frequency range B Interference may occur near equipment marked with following symbol NOTE 1 At 80 MHz and 800 MHz...

Page 14: ...the patient to come into contact at the same time Grounding reliability can only be achieved when the equipment is connected to an equiva lent receptacle marked Hospital Only or Hospital Grade X Insta...

Page 15: ...ages for extended periods or using the unit repeatedly in a high temperature high humidity environments may cause image smearing burn in areas of which brightness is permanently changed lines or a dec...

Page 16: ...each single failed Product that is returned for servicing repair reworking or failure investigation to Seller or to the Authorized Service Provider At least one adhesive yellow label shall be attached...

Reviews: