background image

www.dfi .com

52

Chapter 4 Supported Software

Chapter 4

Intel USB 3.0 Drivers (For Windows 7 and Windows 8.1)

To install the driver, download “KD300 USB3.0 Driver” zip file at our website.

2. Read the license agreement then 

tick “I accept the terms in the 

license agreement”. Click “Next”.

1. Setup is ready to install the driver. 

Click “Next”.

3. Click “Next”.

4. Setup is currently installing the 

driver. After installation has com-

pleted, click “Next”.

5.  Click “Yes, I want to restart 

this computer now” then 

click “Finish”.

 

Restarting the system will 

allow the new software 

installation to take effect.

 

Summary of Contents for KD300-H110

Page 1: ...1 KD300 H110 Q170 MicroATX Industrial Motherboard User s Manual A 480 M 2003 ...

Page 2: ...C Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reason able protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and ...

Page 3: ...rts 18 PS 2 Keyboad Mouse Port 18 COM Serial Ports 19 Graphics Interfaces 20 RJ45 LAN Ports 21 USB Ports 21 Audio 22 I O Connectors 23 SATA Serial ATA Connectors 23 Digital I O Connector 23 Cooling Fan Connectors 24 Power Connectors 24 Chassis Intrusion Connector 25 Front Panel Connector 25 LAN LED Connector 26 S PDIF Connector 26 SMBus Connector 27 Standby Power LED 27 LPC Connector 28 Expansion ...

Page 4: ...xtra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it 2 Wear an antistatic wrist strap 3 Do all preparation work on a static free surface 4 Hold the device only by its edges Be careful not to touch any of the components contacts or connections 5 Avoid touching the pins...

Page 5: ...00mm 2 x COM ports Serial ATA data cable Length 500mm Thermal solution For 35W Height 37 3mm Thermal solution For 65W Height 72 8mm USB 3 0 port cable Length 320mm The board and accessories in the package may not come similar to the information listed above This may differ in accordance to the sales region or models in which it was sold For more information about the standard package in your regio...

Page 6: ...0Mbps 1 x Intel I219LM PCIe with iAMT 11 6 10 100 1000Mbps only Core i7 i5 supports iAMT REAR I O Ethernet 2 x GbE RJ 45 USB 4 x USB 3 0 2 x USB 2 0 Serial 1 x RS 232 422 485 RS 232 with power DB 9 PS 2 1 x PS 2 mini DIN 6 Display 1 x VGA 1 x DVI I DVI D signal 1 x DP Audio 1 x Line out 1 x Mic in INTERNAL I O Serial 1 x RS 232 422 485 RS 232 w power 2 54mm pitch 4 x RS 232 2 54mm pitch USB KD300 ...

Page 7: ...tandby power source of your power supply must support 720mA Wake On USB This function allows you to use a USB keyboard or USB mouse to wake up a system from the S3 STR Suspend To RAM state RTC Timer The RTC installed on the system board allows your system to automatically power on on the set date and time ACPI STR The system board is designed to meet the ACPI Advanced Configuration and Power Inter...

Page 8: ...able of running at a maximum transmis sion speed of up to 5 Gbit s 625 MB s and is faster than USB 2 0 480 Mbit s or 60 MB s and USB 1 1 12Mb s USB 3 0 reduces the time required for data transmission reduces power consumption and is backward compatible with USB 2 0 It is a marked improvement in device transfer speeds between your computer and a wide range of simultaneously accessible external Plug...

Page 9: ...ED 7 8 SPI Flash BIOS 1 2 Nuvoton NCT6106D Chassis Intrusion SATA 1 1 SATA 3 SATA 0 SATA 2 SATA 3 0 1 1 7 1 7 7 7 1 3 PTN3355 1 5 12V Power 4 8 COM 1 RS232 422 485 Select JP10 JP17 COM 1 RS232 422 485 Select JP8 COM 1 RS232 Power Select JP9 5 1 6 2 5 1 6 2 5 1 6 2 5 1 6 2 JP7 1 2 9 DDR4_1 DDR4_2 DDR4_3 DDR4_4 Socket LGA1151 1 2 SMBus JP19 JP18 5 1 2 5 6 1 2 6 5 1 2 6 5 1 2 6 5 JP12 JP11 JP13 PCI 1...

Page 10: ...letely different However we highly recommend using identical DIMMs Not all slots need to be populated Dual Channel DIMMs of the same memory configuration are on different channels Installing the DIMM Module Note The system board used in the following illustrations may not resemble the actual board These illustrations are for reference only 1 Make sure the PC and all other peripheral devices connec...

Page 11: ...ep the protective cap RMA requests will be accepted and pro cessed only if the LGA 1151 socket comes with the protective cap Note The system board used in the following illustrations may not resemble the actual board These illustrations are for reference only 7 Seat the module vertically pressing it down firmly until it is completely seated in the socket 6 Grasping the module by its edges position...

Page 12: ...d cables 3 Locate the LGA 1151 CPU socket on the system board 4 Unlock the socket by push ing the load lever down moving it sideways until it is released from the reten tion tab then lift the load lever up Retention tab Load lever 6 Remove the protective cap from the CPU socket The cap is used to protect the CPU socket against dust and harmful particles Remove the protective cap only when you are ...

Page 13: ...U must align with the corner of the CPU socket shown on the photo The CPU s notch will at the same time fit into the socket s alignment key Alignment key Alignment key Gold triangular mark 8 Close the load plate then push the load lever down While closing the load plate make sure the front edge of the load plate slides under the retention knob Retention knob 9 Hook the load lever under the retenti...

Page 14: ...heat sink already has a patch of thermal paste on its underside Peel the strip that covers the paste before you place the fan heat sink on top of the CPU 2 Place the heat sink on top of the CPU The 4 screw around the heat sink which are used to secure the heat sink onto the sys tem board must match the 4 mounting holes around the socket Mounting hole 3 Orient the heat sink such that the CPU fan s ...

Page 15: ...setting COM 2 COM 1 JP11 COM 2 2 1 9 JP7 COM 1 JP8 COM 1 JP10 COM 1 JP12 COM 2 JP13 COM 2 JP7 COM1 JP11 COM2 COM 1 COM 2 1 2 3 4 5 6 7 8 9 1 2 On RS232 default 3 4 On RS422 Full Duplex 5 6 On RS485 2 4 6 1 3 5 2 4 6 1 3 5 2 4 6 1 3 5 2 1 9 Pin RS232 RS422 Full Duplex RS485 1 DCD RXD DATA 2 RD RXD DATA 3 TD TXD N C 4 DTR TXD N C 5 GND GND GND 6 DSR N C N C 7 RTS N C N C 8 CTS N C N C 9 RI N C N C J...

Page 16: ...pin functions of COM 1 and COM 2 will vary according to JP9 s and JP14 s setting respectively COM 1 COM 2 1 2 3 4 5 6 7 8 9 2 1 9 Pin RS232 RS232 with power 1 DCD 12V 2 RD RD 3 TD TD 4 DTR DTR 5 GND GND 6 DSR DSR 7 RTS RTS 8 CTS CTS 9 RI 5V JP9 COM 1 1 3 RI 2 4 DCD On RS232 default 3 5 5V 4 6 12V On RS232 with power JP14 COM 2 2 4 6 1 3 5 2 4 6 1 3 5 1 3 RI 2 4 DCD On RS232 default 3 5 5V 4 6 12V ...

Page 17: ...o On Wait for a few seconds and set JP1 back to its default setting pins 1 and 2 On 3 Now plug the power cord and power on the system JP1 2 3 On Clear CMOS Data 1 2 On Normal default 3 1 2 3 1 2 USB Power Select 2 3 On 5V 1 3 2 1 2 On 5VDU default 1 3 JP15 JP16 JP19 JP18 The power of the USB connectors voltage buses can be configured to either 5VDU or 5V The jumpers i e JP31 JP32 JP33 JP34 and JP3...

Page 18: ...onnect a PS 2 mouse and a PS 2 keyboard The PS 2 mouse port uses IRQ12 Wake On PS 2 Keyboard Mouse The Wake On PS 2 Keyboard Mouse function allows you to use the PS 2 keyboard or PS 2 mouse to power on the system To use this function BIOS Setting Configure the wake up function of PS 2 keyboard mouse in the Advanced menu ACPI Con figuration submenu of the BIOS Refer to the chapter 3 for more inform...

Page 19: ...M1 COM2 RS232 Power Select in this chapter for more information COM 3 to COM 6 are fixed at RS232 The pin functions are listed at right The serial ports are asynchronous communication ports with 16C550A compatible UARTs that can be used with modems serial printers remote display terminals and other serial devices Connecting External Serial Ports Your COM port may come mounted on a card edge bracke...

Page 20: ...t is used to connect a LCD monitor This port supports DVI D signal only Con nect the display device s cable connector to the DVI I port After plugging the cable connector into the port gently tighten the cable screws to hold the connector in place DP Port The DP port which carries both digital audio and video signals is used to connect a LCD monitor or a digital TV that has the DP port BIOS Settin...

Page 21: ...ors allow you to connect 4 additional USB 2 0 ports USB 7 8 9 10 The 20 pin connector allows you to connect 2 additional USB 3 0 ports USB 5 6 for KD300 Q170 The additional USB ports may be mounted on a card edge bracket Install the card edge bracket to an available slot at the rear of the system chassis and then insert the USB port cables to a connector BIOS Setting Configure these onboard USB de...

Page 22: ...end To RAM state Audio Rear Audio The system board is equipped with 2 audio jacks A jack is a one hole connecting interface for inserting a plug Line out Jack Lime This jack is used to connect a headphone or external speakers Mic in Pink This jack is used to connect an external microphone Front Audio The front audio connector allows you to connect to the line out and mic in jacks that are at the f...

Page 23: ...A device BIOS Setting Configure the Serial ATA drives in the Advanced menu SATA Configuration submenu of the BIOS Refer to the chapter 3 for more information Features LAN 1 SATA 0 SATA 1 SATA 3 0 6Gb s 7 RXN GND TXP TXN GND 1 RXP GND The 8 bit Digital I O connector provides powering on function to external devices that are connected to these connectors The pin functions of the 8 bit digital I O co...

Page 24: ...ore 12VDC current to the processor s Voltage Regulator Module VRM The power connectors from the power supply unit are designed to fit the 24 pin and 8 pin connectors in only one orientation Make sure to find the proper orientation before plugging the connectors The system board requires a minimum of 300 Watt power supply to operate Your system configuration CPU power amount of memory add in cards ...

Page 25: ...h is used to power on or off the system Pin Pin Assignment Pin Pin Assignment HD LED 3 HDD Power PWR LED 2 LED Power 5 Signal 4 LED Power RESET 7 Ground 6 Signal 9 RST Signal ATX SW 8 Ground 11 N C 10 Signal Chassis Intrusion Connector The board supports the chassis intrusion detection function Connect the chassis intrusion sensor cable from the chassis to this connector When the system s power is...

Page 26: ...onnector Make sure pin 1 of the audio cable is aligned with pin 1 of the S PDIF connector 1 5 5V SPDIF out Ground SPDIF in LAN 1 S PDIF LAN LED Connector LAN LED LAN 1 7 8 1 2 The LAN LED connector is used to detect the connection state of RJ45 LAN ports when the connection is made to an active network via a cable The pin functions of the LAN LED con nector are listed below Pin Pin Assignment Pin ...

Page 27: ...ne to act as a master by initiating data transfer SMBus Connector 1 2 5 GND SMB_Data SMB_CLK 3V3DU SMB_Alert SMBus LAN 1 Standby Power LED This LED will lit red when the system is in the standby mode It indicates that there is power on the system board Power off the PC and then unplug the power cord prior to installing any devices Failure to do so will cause severe damage to the motherboard and co...

Page 28: ...fer to the Intel Low Pin Count Interface Specification Revision 1 1 The table below indicates the pin functions of the LPC connector LAN 1 LPC 2 1 1413 Pin Pin Assignment Pin Pin Assignment 1 L_CLK 2 L_AD1 3 L_RST 4 L_AD0 5 L_FRAME 6 3V3 7 L_AD3 8 GND 9 L_AD2 10 11 INT_SERIRQ 12 GND 13 5VSB 14 5V Expansion Slots PCI Slot The PCI slot supports expansion cards that comply with PCI specifications You...

Page 29: ...k and CMOS memory It is an auxiliary source of power when the main power is shut off Safety Measures Danger of explosion if battery incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to local ordinance Battery LAN 1 Battery ...

Page 30: ...fter you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appear on the screen If the message disappears before you respond restart the system or press the Reset button You may also restart the system by pressing the Ctrl Alt and Del keys simultaneously Legends Scroll Bar When a scroll bar appears t...

Page 31: ... System Date KD300 B185 02A Intel 6th and 7th Generation CPU Intel R Core TM i7 6700T CPU 2 80GHz 0x506E3 SKYLAKE DT HALO 2800 MHz 03 R0 S0 N0 Stepping 32 KB 32 KB 256 KB 8192 KB 4 Core s 8 Thread s 000000C2 4096 MB 2133 MHz 4096 MB Not Installed Not Installed Not Installed 31 D1 Stepping SKL PCH H Q170 11 8 50 3399 CORPORATE 15 33 48 06 05 2018 Advanced Boot Exit Main Rev 5 0 Advanced The Advance...

Page 32: ...ter a power failure G3 state Always On The system working state Always Off Off except for trickle current to devices such as the power button Wake On RTC Automatically power the system on at a particular time every day from the Real time clock battery Wake up time When Wake On RTC is set to enabled specify the wake up time of the day hour 00 23 minute 00 59 second 00 59 Note Under Dual Boot Type o...

Page 33: ...up Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Video Configuration This section configures the video settings Primary Display Set the initial priority Internal Graphics Device Keep IGFX enabled or disabled based on the setup options Boot display Set the display device combination Note To control Primary Display Boot Display first go to Boot ...

Page 34: ...on is used to configure the audio settings HD Audio Control the detection of the HD Audio device Disabled HDA will be unconditionally disabled Enabled HDA will be unconditionally enabled Auto HDA will be enabled if present disabled otherwise Audio Configuration HD Audio Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit In...

Page 35: ...Port 1 Port 1 Hot Plug Serial ATA Port 2 Port 2 Hot Plug Serial ATA Port 3 Port 3 Hot Plug Serial ATA Port 4 Port 4 Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Enabled Auto AHCI Enabled Disabled Enabled Disabled Enabled Disabled Enabled Disabled Enabled Not Installed Not Installed Not...

Page 36: ...ge Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Enabled PCI Express Root Port 4 5 17 This field is used to enable or disable the PCI Express Root Port PCIe Speed Select the speed of the PCI Express Root Port Auto Gen1 Gen2 or Gen3 Hot Plug This field is used to enable or disable the PCI Express Hot Plug Control the PCI Express...

Page 37: ...le the Intel Active Management Technology Intel AMT BIOS extension Please refer to Chapter 6 for more information When disabled AMT BIOS Features are no longer supported and user is no longer able to access MEBx Setup Note This option does not dis able Manageability Fea tures in FW Active Management Technology Support Intel AMT Support Enabled Un Configure ME Disabled Advanced F1 Help Select Item ...

Page 38: ...Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Dynamic EFI DEBUG This field is used to turn on or off the function to output debug message from COM port If set to on relevant EFI debug information will show up Enable it to output debug message from COM port Dynamic EFI DEBUG On EFI debug print level 0x80000000 EFI debug serial port 0x3F8 EFI debug baud rate...

Page 39: ...stem or CPU fan should be turned on and operate at the designated speed The range is from 0 127o C Fan Speed Count 1 to Fan Speed Count 4 Set the fan speed The range is from 1 100 full speed Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Enable Disable Smart Fan SYS Smart Fan Control Boundary 1 ...

Page 40: ...Rev 5 0 COM Port 1 to COM Port 6 Configure the settings to use the serial port Disable No configuration Enable User configuration RS485 Auto Flow Enable or disable RS485 auto flow WDT Enable or disable the watchdog function A counter will appear if you select to enable WDT Input any value between 1 to 255 seconds Case Open Enable or disable the case open detection function Advanced F1 Help Select ...

Page 41: ...deH2O Setup Utility Rev 5 0 0 000 V 4 860 V 12 056 V 1 184 V 3 104 V 3 264 V 35 0 C 95 0 F 42 0 C 107 6 F 0 RPM 0 RPM 0 RPM Console Redirection This section configures settings relevant to console redirection Enable Console Redirec tion Function Console Redirection Setup Console Serial Redirect Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select Sub...

Page 42: ...terminal type VT_100 VT_100 VT_UTF8 or PC_ANSI Baud Rate Select baud rate 115200 57600 38400 19200 9600 4800 2400 or 1200 Data Bits Select data bits 7 bits or 8 bits Parity Select parity bits none even or odd Stop Bits Select stop bits 1 bit or 2 bits Flow Control Select flow control type none RTS CTS or XON XOFF PortEnable UseGlobalSetting Advanced F1 Help Select Item F5 F6 Change Values F9 Setup...

Page 43: ... Select one of the supported operation to change TPM2 state Clear TPM Remove all TPM context associated with a specific owner Set Supervisor Password Set the supervisor s password and the length of the password must be greater than one character When Hidden don t ex poses TPM to 0 Current TPM Device TPM State TPM Availability TPM Operation Clear TPM Supervisor Password Set Supervisor Password Main...

Page 44: ...Network Stack UEFI IPv4 IPv6 Legacy Legacy PXE OPROM only Selects Power on state for Numlock Numlock Boot Type Network Stack PXE Boot capability USB Boot Quiet Boot Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Security Exit Rev 5 0 On Dual Boot Type Disabled Disabled Enabled Disabled Boot...

Page 45: ...vice Restore Setting from file This field will appear only when a USB flash device is detected Select this field to restore setting from the USB flash device Exit system setup and save your changes Exit Saving Changes Load Optimal Defaults Discard Changes Save Setting to file Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save ...

Page 46: ...that the MAC address should be burned or not Notice BIOS SPI ROM 1 The Intel Management Engine has already been integrated into this system board Due to the safety concerns the BIOS SPI ROM chip cannot be removed from this system board and used on another system board of the same model 2 The BIOS SPI ROM on this system board must be the original equipment from the factory and cannot be used to rep...

Page 47: ...tility The Intel Chipset Software Installation Utility is used for updating Windows INF files so that the Intel chipset can be recognized and configured properly in the system To install the utility download KD300 Chipset Driver zip file at our website 1 Setup is ready to install the utility Click Next 2 Read the license agreement then click Accept 3 Go through the readme document for more install...

Page 48: ...iver and the system rebooted the screen will turn blank for 1 to 2 minutes while WinSAT is running before the Win dows 7 8 1 10 desktop appears The blank screen period is the time Windows is testing the graphics performance We recommend that you skip this process by disabling this function then click Next 4 Setup is now installing the driver Click Next to continue 3 Go through the readme document ...

Page 49: ...ish Restarting the system will allow the new software installation to take effect 1 Setup is ready to install the driver Click Next Intel LAN Drivers To install the driver download KD300 LAN Driver zip file at our website 1 Setup is ready to install the driver Click Next 2 Click I accept the terms in the license agreement then click Next 3 Select the program features you want installed then click ...

Page 50: ... to begin the installation 6 After completing installa tion click Finish Kernel Mode Driver Framework For Windows 7 only To install the driver download KD300 KMDF zip file at our website 1 Click Yes to install the update 2 The update is installed now 3 Click Restart Now to restart your computer when the installation is complete ...

Page 51: ...t our website 1 Setup is ready to install the driver Click Next 2 Read the license agreement then tick I accept the terms in the License Agree ment Click Next 3 Click Next to install to the default folder or click Change to choose another destination folder 4 Please wait while the prod uct is being installed 5 After completing installa tion click Finish ...

Page 52: ...ead the license agreement then tick I accept the terms in the license agreement Click Next 1 Setup is ready to install the driver Click Next 3 Click Next 4 Setup is currently installing the driver After installation has com pleted click Next 5 Click Yes I want to restart this computer now then click Finish Restarting the system will allow the new software installation to take effect ...

Page 53: ...are fully Tick I accept the terms in the Li cense Agreement then click Next Intel Rapid Storage Technology The Intel Rapid Storage Technology is a utility that allows you to monitor the current status of the SATA drives It enables enhanced performance and power management for the storage subsystem To install the driver download KD300 IRST Driver zip file at our website Please refer to Chapter 5 fo...

Page 54: ...ver Click Next 5 Setup is now installing the driver 3 Go through the readme docu ment for system requirements and installation tips then click Next 6 Click Yes I want to restart this computer now then click Finish Restarting the system will allow the new software installation to take effect ...

Page 55: ...e at our website 1 Setup is now extracting files Note Before installing Microsoft Framework 4 5 make sure you have updated your Windows 7 operating system to Service Pack 3 2 Read the license agreement care fully Click I have read and accept the terms of the License Agree ment then click Install 4 Click Finish 3 Setup is now installing the driver ...

Page 56: ...2 Utility zip file at our website 1 The setup program is preparing to install the driver 2 The setup program is now ready to install the utility Click Next 3 Click I accept the terms in the license agreement and then click Next 4 Enter the necessary information and then click Next 5 Select a setup type and then click Next 6 Click Install ...

Page 57: ...re Chapter 4 7 TPM requires installing the Micro soft Visual C package prior to installing the utility Click Install 8 The setup program is currently installing the Microsoft Visual C package 9 Click Finish 10 Click Yes to restart your system ...

Page 58: ...ftware Chapter 4 Infineon TPM 2 0 Driver and Tool optional To install the driver download KD300 TPM2 0 Hotfix zip file at our website 1 Click OK 2 Click Yes 3 Setup is now installing the up dates 4 Click Restart now to restart your system ...

Page 59: ...To install the reader download KD300 H110 Q170 Driver Package iso file at our website 1 Click Next to install or click Change Destination Folder to select another folder 2 Click Install to begin instal lation 3 Setup is now installing the driver 4 Click Finish to exit installation ...

Page 60: ... uses two new identical hard disk drives to read and write data in parallel interleaved stacks Data is divided into stripes and each stripe is written alternately between two disk drives This improves the I O performance of the drives at different channel however it is not fault tolerant A failed disk will result in data loss in the disk array RAID 1 Mirroring Disk Array with Fault Tolerance RAID ...

Page 61: ...ID volumes To set the boot type enter the Insyde BIOS and go to Boot Boot Type 1 Go to the Advanced menu of the Insyde BIOS and select UEFI Device Manager Device Manager Setting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME Configuration Active Management Technology Support MEBX Configuration Debug Con...

Page 62: ...u to monitor the current status of the RAID volume and or SATA drives It enables enhanced performance and power management for the storage subsystem 1 Download KD300 IRST Driver zip file at our website 3 Read the license agree ment and click I accept the terms in the License Agreement Then click Next 2 Setup is ready to install the utility Click Next 4 Go through the readme document to view system...

Page 63: ...www dfi com 63 Chapter 5 RAID Chapter 5 7 Click Yes I want to restart this computer now to complete the installation and then click Finish ...

Page 64: ...lerting when critical software agents are removed Enable Intel AMT in the Insyde BIOS 1 Power on the system then press Del to enter the main menu of the Insyde BIOS 2 In the Advanced menu select Active Management Technology Support 3 Select Enabled in the Intel AMT Support field Rev 5 0 When disabled AMT BIOS Features are no longer supported and user is no longer able to access MEBx Setup Note Thi...

Page 65: ...ity Security Boot Rev 5 0 Exit MEBX Configuration Set ting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME Configuration Active Management Technology Support MEBX Configuration Debug Configuration UEFI Device Manager SIO NUVOTON6106D Console Redirection Main Advanced F1 Help Select Item F5 F6 Change Valu...

Page 66: ...sion v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exit Intel R ME Password Move Highlight Enter Select Entry Esc Exit Verify password 7 Select Intel R ME General Settings then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Co...

Page 67: ... provided under Intel R ME Password then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME PLATFORM CONFIGURATION Change ME Password Local FW Update Enabled Intel R ME New Password Move Highlight Enter Select Entry Esc Exit Intel R ME Password Change ME Password Local FW Update Enabled Int...

Page 68: ... Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes 14 In the Intel R AMT Configuration menu select SOL Storage Redirection KVM then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirectio...

Page 69: ...abled Move Highlight Enter Complete Entry Esc Discard Changes 18 Select KVM Feature Selection then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved SOL Storage Redirection KVM Username and password Enabled SOL Enabled Storage Redirection Enabled KVM Featur...

Page 70: ...oose to use a password only during setup and configuration or to use a pass word anytime the system is being accessed Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Password Policy Anytime Network Setup Activate Network Access Un...

Page 71: ...ME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update 26 Select Domain Name then press Enter Enter the computer s domain name then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME NETWORK NAME SETTINGS Host Name Domain Name Shared Dedicated FQDN Dynamic DNS Update Ent...

Page 72: ...9 Copyright C 2003 16 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit TCP IP SETTINGS Wired LAN IPV4 Configuration 29 Select Periodic Update Interval then press Enter Enter value then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME NETWORK NAME SETTINGS H...

Page 73: ... 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 34 Select Subnet Mask Address then press Enter Enter address then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask ...

Page 74: ...C 2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask Address 0 0 0 0 Default Gateway Address 0 0 0 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 37 Select Alternate DNS Address then press Enter Enter address then press Enter Intel R Management Engine BIOS Extension v...

Page 75: ...ent Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 42 In the Intel R Remote Setup And Configuration menu select Provisioning Re cord then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3399 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R REMOTE SETUP AND CON...

Page 76: ...d INTEL R REMOTE CONFIGURATION Start Configuration Move Highlight Enter Select Entry Esc Exit This will activate Remote Configuration Continue Y N 46 Press Esc until you return to the Intel R Remote Setup And Configuration menu Select TLS PKI then press Enter Select Remote Configuration then press Enter Select Enabled or Disabled then press Enter Enter FQDN of provisioning server Intel R Managemen...

Page 77: ...256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 SHA256 Hash Name Active Default Algorithm VeriSign Class 3 VeriSign Class 3 Go Daddy Class 2 Comodo AAA CA Starfield Class 2 VeriSign Class 3 VeriSign Class 3 VeriSign Class 3 GTE CyberTrust G1 Baltimore Cyber Tr Cyber Trust Global Verizon Global Ro Entrust net CA 2 Entrust Root CA V...

Page 78: ...the monitor s power switch is on 2 Check that one end of the monitor s power cord is properly attached to the monitor and the other end is plugged into a working AC outlet If necessary try another outlet 3 Check that the video input cable is properly attached to the monitor and the system s display adapter 4 Adjust the brightness of the display by turning the monitor s brightness control knob The ...

Page 79: ...rks by attaching it to a serial port that is working and configured correctly If the serial device does not work either the cable or the serial device has a problem If the serial device works the problem may be due to the onboard I O or the address setting 4 Make sure the COM settings and I O address are configured correctly Keyboard Nothing happens when a key on the keyboard was pressed 1 Make su...

Reviews: