Fix Fan Speed Count

Set the fix fan speed. The range is from 1-100% (full speed).

Boundary 1 to Boundary 4

Set the boundary temperatures that determine the operation of the fan with different 

fan speeds accordingly. For example, when the system or the CPU temperature reaches 

boundary temperature 1, the system or CPU fan should be turned on and operate at 

the designated speed. The range is from 0-127

o

C. 

Fan Speed Count 1 to Fan Speed Count 4 

Set the fan speed. The range is from 1-100% (full speed).

COM Port 1

Configure the settings to use the serial port.

Disable

  No configuration

Enable

    User con

fi

 guration

Type

Choose RS232/RS485/RS422 (Peer-to-Peer) for COM type.

WDT

Enable or disable the watchdog function. A counter will appear if you select to enable 
WDT. Input any value between 1 to 255 seconds.

Case Open

Enable or disable the case open detection.

ERP Support

Enable or disable ERP Support Setting.

PC Health Status

This section displays the PC health status.

PC Health Status

Voltage

   VBAT

   VCORE

   VDDQ

   5V

   +12V

Temperature

   System (

o

C/

o

F)

   CPU (

o

C/

o

F)

Fan Speed

   CPU FAN

   

Advanced

F1   

Help             

  

/

    

Select Item                  

F5/F6 

Change Values                 

F9   

Setup Defaults

Esc  

Exit             

 

/

  

Select Item                  

Enter 

Select 

 SubMenu             

F10 

Save and Exit

InsydeH2O Setup Utility

     Rev. 5.0

 3.056  V

 0.896  V

 1.200  V

 4.939  V

12.144  V

38.5 C/  101.3 F

45.5 C/  113.9 F

 0 RPM

  

Summary of Contents for AL553-BN-N3350

Page 1: ...1 KU553 Embedded SBC 3 5 User s Manual A50710920 ...

Page 2: ...C Statement on Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reason able protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and ...

Page 3: ...14 9 36V DC in 14 Graphics Interfaces 15 RJ45 LAN Ports 15 USB Ports 16 I O Connectors 17 Digital I O Connector 17 Front Audio Connector 17 COM Serial Port 18 Standby Power LED 19 Front Panel Connector 19 SATA Serial ATA Connector 20 SATA Serial ATA Power Connector 20 LVDS LCD Panel Connector 21 LCD Inverter Power Connector 21 Cooling Fan Connector 22 Expansion Slots 22 SMBus Connector 23 Chassis ...

Page 4: ...extra care in han dling them to ensure against electrostatic build up 1 To prevent electrostatic build up leave the system board in its anti static bag until you are ready to install it 2 Wear an antistatic wrist strap 3 Do all preparation work on a static free surface 4 Hold the device only by its edges Be careful not to touch any of the components contacts or connections 5 Avoid touching the pin...

Page 5: ...nd accessories in the package may not come similar to the information listed above This may differ in accordance to the sales region or models in which it was sold For more information about the standard package in your region please contact your dealer or sales representative Before Using the System Board Before using the system board prepare basic system components If you are installing the syst...

Page 6: ... 1 x Intel I210AT PCIe 10 100 1000Mbps or 1 x Intel I210IT PCIe 10 100 1000Mbps 1 x Intel I219LM PCIe with iAMT11 6 10 100 1000Mbps Celeron Processor 1 x Intel I210AT PCIe 10 100 1000Mbps or 1 x Intel I210IT PCIe 10 100 1000Mbps 1 x Intel I219V PCIe 10 100 1000Mbps REAR I O Ethernet 2 x GbE RJ 45 USB 4 x USB 3 0 Display 1 x VGA 1 x DP INTERNAL I O Serial 1 x RS 232 422 485 2 0mm pitch USB 2 x USB ...

Page 7: ...failure you may choose to either power on the system manually or let the system power on automatically USB The system board supports the USB 3 0 It is capable of running at a maximum transmission speed of up to 5 Gbit s 625 MB s and is faster than USB 2 0 480 Mbit s or 60 MB s and USB 1 1 12Mb s USB 3 0 reduces the time required for data transmission reduces power consumption and is backward compa...

Page 8: ...1 1 CPU Fan 1 SATA 3 0 SATA 0 Standby Power LED DDR4 SODIMM CH7517 1 5 SMBus 2 2 1 10 9 DIO Intel I210AT or I210IT opt SPI Flash BIOS 10 9 Front Audio 1 2 PTN3460 LCD Inverter Power 1 1 2 39 40 1 1 2 5 6 2 10 M 2 B Key Signal Select JP7 1 Front Panel 1 USB 7 8 SATA Power 3 1 2 5 6 1 Backlight Brightness Select JP12 Panel Power Select JP13 LVDS LCD Panel M 2 E Key 2 1 9 COM1 Battery M 2 B Key Mini ...

Page 9: ...PI M 2 E key USB 2 0 LVDS DP I210AT I219LM PCIe x1 PCIe x1 SATA 1x RS 232 422 485 1x FAN Control H W Monitor PCIe x1 USB 2 0 USB 2 0 2x SATA 3 0 USB 3 0 USB 2 0 USB 3 0 4x PTN3460 eDP ALC888 HDA Audio Jack Line out Front Audio GLAN 2 GLAN 1 SIM opt M 2 B key USB 2 0 PCIe x1 SATA 3 0 PCIe x1 USB 3 1 Gen1 opt Mechanical Diagram 0 6 11 76 40 92 67 43 84 93 103 49 120 09 137 66 140 146 0 18 98 102 0 6...

Page 10: ... chassis If a wrist strap is unavailable establish and maintain contact with the system chassis throughout any procedures requiring ESD protection Important When the Standby Power LED is red it indicates that there is power on the system board Power off the PC then unplug the power cord prior to installing any devices Failure to do so will cause severe damage to the motherboard and components One ...

Page 11: ...le until it slips down into the socket The contact fingers on the edge of the module will almost completely disappear inside the socket Clip Installing the SODIMM Module 1 Make sure the PC and all other peripheral devices connected to it has been powered down 2 Disconnect all power cords and cables 3 Locate the SODIMM socket on the system board 4 Note the key on the socket The key ensures the modu...

Page 12: ... the system with the default val ues stored in the ROM BIOS a CMOS data becomes corrupted b You forgot the supervisor or user password To load the default values stored in the ROM BIOS please follow the steps below 1 Power off the system and unplug the power cord 2 Set JP1 pins 2 and 3 to On Wait for a few seconds and set JP1 back to its default setting pins 1 and 2 On 3 Now plug the power cord an...

Page 13: ...ch the LCD panel s specification Selecting the incorrect voltage will seriously damage the LCD panel 5 1 3 2 4 6 5 1 3 2 4 6 JP12 is used to select the power level of backlight brightness control 3 3V or 5V Backlight Brightness Select 2 3 On 5V 1 2 On 3 3V default Important Before powering on the system make sure that the power settings of JP12 match the power specification of backlight control Se...

Page 14: ...ht angle connector is considered a low power solution Connect a DC power cord to this connector Using a voltage more than the recommended range may fail to boot the sys tem or cause damage to the system board The 4 pin right angle connector on the system board co lays with a DC in jack optional or 4 pin vertical type connector optional as the photo displayed below DC in Jack optional 4 pin Vertica...

Page 15: ...imultaneously The interface which is developed by VESA delivers higher performance features than any other digital interfaces Driver Installation Install the graphics driver Refer to Chapter 4 for more information RJ45 LAN Ports Features 1 Intel I210AT I210IT PCI Express Gigabit Ethernet controller 1 Intel I219LM PCIe with iAMT11 6 for CoreTM processors 1 Intel I219V PCIe for Celeron processor The...

Page 16: ...orts may be mounted on a card edge bracket Install the card edge bracket to an available slot at the rear of the system chassis and then insert the USB port cables to a connector BIOS Setting Configure the onboard USB in the Advanced menu USB Configuration submenu of the BIOS Refer to Chapter 3 for more information Wake On USB Keyboard Mouse The Wake On USB Keyboard Mouse function allows you to us...

Page 17: ...dio Connector Front Audio 1 2 10 9 Front Audio The front audio connector allows you to connect to the line out and mic in jacks that are at the front panel of your system Driver Installation Install the audio driver Refer to the Chapter 4 for more information 3 Digital I O 3 10 9 2 1 Front Audio Connector Pin Function 1 Mic L 2 GND 3 Mic R 4 NC 5 Line R 6 Mic JD 7 GND 8 NC 9 Line L 10 Line JD Note...

Page 18: ...the rear of the system chassis then insert the serial port cable to the COM connector Make sure the colored stripe on the ribbon cable is aligned with pin 1 of the COM connector BIOS Setting Configure the serial COM port in the Advanced menu SIO NUVOTON6106D submenu of the BIOS Refer to Chapter 3 for more information 2 1 9 COM 1 RS232 422 485 3 COM 1 Pin RS232 RS422 Full Duplex RS485 1 DCD TX B RX...

Page 19: ...you to reboot without having to power off the system PWR BTN Power Button This button is used to power on or off the system 3 Front Panel Pin Pin Assignment Pin Pin Assignment HDD LED 6 HD_LED PWR BTN 1 Power Button 2 LED Power 3 Ground RESET BTN 3 Ground PWR LED 2 LED Power 5 Reset Button 4 SUS_LED HDD LED PWR LED RESET BTN PWR BTN 1 2 5 6 Standby Power LED This LED will lit red when the system i...

Page 20: ...TA 3 0 port with data transfer rate up to 6Gb s Integrated Advanced Host Controller Interface AHCI controller The Serial ATA connector is used to connect the Serial ATA device Connect one end of the Se rial ATA data cable to a SATA connector and the other end to your Serial ATA device BIOS Setting Configure the Serial ATA drive in the Advanced menu SATA Configuration submenu of the BIOS Refer to C...

Page 21: ...Out2 Odd_2 10 LVDS_Out6 Even_2 11 LVDS_Out2 Odd_2 12 LVDS_Out6 Even_2 13 GND 14 GND 15 LVDS_Out1 Odd_1 16 LVDS_Out5 Even_1 17 LVDS_Out1 Odd_1 18 LVDS_Out5 Even_1 19 GND 20 GND 21 LVDS_Out0 Odd_0 22 LVDS_Out4 Even_0 23 LVDS_Out0 Odd_0 24 LVDS_Out4 Even_0 25 GND 26 GND 27 LVDS_CLK1 Odd_CLK 28 LVDS_CLK2 Even_CLK 29 LVDS_CLK1 Odd_CLK 30 LVDS_CLK2 Even_CLK 31 GND 32 GND 33 DDC_CLK 34 NC 35 DDC_DATA 36 ...

Page 22: ...PCIe socket supports PCIe x1 and USB 2 0 or USB 3 1 Gen 1 optional sig nals and is used to install a Mini PCIe card SIM Optional The SIM slot on the system board is used to insert a SIM card 3 M 2 E Key Full size Mni PCIe SIM opt Cooling Fan Connector The fan connector is used to connect the cooling fan The cooling fan will provide adequate airflow throughout the chassis to prevent overheating the...

Page 23: ...hassis intrusion detection function Connect the chassis intrusion sensor cable from the chassis to this connector When the system s power is on and a chassis intrusion occurred an alarm will sound When the system s power is off and a chassis intrusion occurred the alarm will sound only when the system restarts BIOS Setting Configure the chassis intrusion detection function in the Advanced menu SIO...

Page 24: ...s an auxiliary source of power when the main power is shut off Safety Measures Danger of explosion if battery incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to local ordinance Connect to the battery connector Battery Battery Connector 1 3 3V GND 2 3 ...

Page 25: ... system to run After you power up the system the BIOS message appears on the screen and the memory count begins After the memory test the message Press DEL to run setup will appear on the screen If the message disappears before you respond restart the system or press the Reset button You may also restart the system by pressing the Ctrl Alt and Del keys simultaneously Note The BIOS is constantly up...

Page 26: ...to 59 IN CREASE REDUCE InsydeH2O Setup Utility Security F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit Project Name BIOS Version Processor Type CPUID CPU Speed CPU Stepping L1 Data Cache L1 Instruction Cache L2 Cache L3 Cache Number Of Processors Microcode Rev Total Memory System Memory Speed SODIMM 0 PCH Rev SKU Intel ME Versi...

Page 27: ... On The system working state Always Off Off except for trickle current to devices such as the power button Wake On RTC Automatically power the system on at a particular time every day from the Real time clock battery Wake up time When Wake On RTC is set to enabled specify the wake up time of the day hour 00 23 minute 00 59 second 00 59 Note Under Dual Boot Type or UEFI Boot Type mode if Quiet Boot...

Page 28: ...ted Backlight Type Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Auto Auto DP1 VGA Disabled Normal PWM Mode Primary Display Auto IGFX PEG PCI CPU Configuration This section is used to configure the CPU Intel Speed Step This field is used to enable or disable the Intel Enhanced SpeedStep...

Page 29: ... Bit 36 Bit or 48 Bit LCD Panel Type Select LCD Panel Type 800x480 800x600 1024x768 1366x768 1280x1024 1920x1080 or 1920x1200 Backlight Type This field is only available for Dual Boot Type or Legacy Boot Type mode Select Back light Type Normal PWM Mode Normal DC Mode Invert PWM Mode or Invert DC Mode Audio Configuration This section is used to configure the audio settings Azaliza Control the detec...

Page 30: ...orts and their hot plugs Enable Disable SATA Device SATA Controller s SATA Speed SATA Mode Selection System Acceleration with Intel R Optane TM Memory Serial ATA Port 0 Port 0 Hot Plug Serial ATA Port 2 Port 2 Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Enabled Auto AHCI Disabled Enab...

Page 31: ...Speed Hot Plug Disabled Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Enabled AUTO PCI Express Root Port 1 3 5 6 12 This field is used to enable or disable the PCI Express Root Port PCIe Speed Select the speed of the PCI Express Root Port Auto Gen1 Gen2 or Gen3 Hot Plug This field is us...

Page 32: ...ed F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Rev 5 0 Disabled Me Fw Image Re Flash This field is used to enable or disable the flash ME region MEBX Configuration Configure Intel Active Management Technology Intel AMT in the Intel Management Engine BIOS Extension MEBX section Please refer to Chapter ...

Page 33: ...o enable or disable Intel Active Management Technology Un Configure ME This field is used to enable or disable to un configure ME with resetting MEBX pass word to default Debug Configuration This section configures debug setting Enable it to output debug message from COM port Dynamic EFI DEBUG Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubM...

Page 34: ...ced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Enable Disable Smart Fan CPU Smart Fan Control Boundary 1 Boundary 2 Boundary 3 Boundary 4 Fan Speed Count 1 Fan Speed Count 2 Fan Speed Count 3 Fan Speed Count 4 COM Port 1 Base I O Address Interrupt Type WDT Case Open ERP Support PC Health Status Enabl...

Page 35: ...figure the settings to use the serial port Disable No configuration Enable User configuration Type Choose RS232 RS485 RS422 Peer to Peer for COM type WDT Enable or disable the watchdog function A counter will appear if you select to enable WDT Input any value between 1 to 255 seconds Case Open Enable or disable the case open detection ERP Support Enable or disable ERP Support Setting PC Health Sta...

Page 36: ...l appear like below Enable Console Redirec tion Function Console Redirection Setup Console Serial Redirect Terminal Type Baud Rate Data Bits Parity Stop Bits Flow Control COMA Enable VT 100 115200 N81 Pci Serial Port 0 22 3 Enable VT 100 115200 N81 Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility ...

Page 37: ... enable or disable to use global setting When enabled the global set ting setting of the COM port will be the same as those in Console Redirection section When disabled the global setting setting of the COM port can be configured indepen dently in this section Port Enable Use Global Setting Terminal Type Baud Rate Data Bits Parity Stop Bits Flow Control Advanced F1 Help Select Item F5 F6 Change Va...

Page 38: ...e length of the password must be greater than one character Boot Selects Power on state for Numlock Numlock Boot Type Network Stack PXE Boot capability USB Boot Quiet Boot Main Advanced F1 Help Select Item F5 F6 Change Values F9 Setup Defaults Esc Exit Select Item Enter Select SubMenu F10 Save and Exit InsydeH2O Setup Utility Security Exit Rev 5 0 On Dual Boot Type Disabled Disabled Enabled Disabl...

Page 39: ...ges Select YES and press Enter to exit the system setup without saving your changes Save Setting to file Select this option to save BIOS configuration settings to a USB flash device Restore Setting from file This field will appear only when a USB flash device is detected Select this field to restore setting from the USB flash device Exit system setup and save your changes Exit Saving Changes Load ...

Page 40: ...OS SPI ROM chip cannot be removed from this system board and used on another system board of the same model 2 The BIOS SPI ROM on this system board must be the original equipment from the factory and cannot be used to replace one which has been utilized on other system boards 3 If you do not follow the methods above the Intel Management Engine will not be updated and will cease to be effective Not...

Page 41: ...indows INF files so that the Intel chipset can be recognized and configured properly in the system To install the utility download KU553 Chipset Driver zip file at our website 1 Setup is ready to install the utility Click Next 2 Read the license agreement then click Accept 3 Go through the readme document for more installa tion tips then click Install 5 After completing installa tion click Restart...

Page 42: ...driver and the system rebooted the screen will turn blank for 1 to 2 minutes while WinSAT is running before the Windows 10 desktop appears The blank screen period is the time Windows is testing the graphics perfor mance We recommend that you skip this process by disabling this function then click Next 4 Setup is now installing the driver Click Next to continue 3 Go through the readme document for ...

Page 43: ...ish Restarting the system will allow the new software installation to take effect 1 Setup is ready to install the driver Click Next Intel LAN Driver To install the driver download KU553 LAN Driver zip file at our website 1 Setup is ready to install the driver Click Next 2 Click I accept the terms in the license agreement then click Next 3 Select the program features you want installed then click N...

Page 44: ...stall to begin the installation 6 After completing installa tion click Finish Intel Management Engine Driver To install the driver download KU553 ME Driver zip file at our website 1 Setup is ready to install the driver Click Next 2 Read the license agreement then tick I accept the terms in the License Agree ment Click Next ...

Page 45: ...on folder 4 Please wait while the prod uct is being installed 4 After completing installa tion click Finish IO Driver To install the driver download KU553 IO Driver zip file at our website 1 Setup is ready to install the driver Click Next 2 Read the license agreement care fully Tick I accept the terms in the Li cense Agreement then click Next ...

Page 46: ...ver Click Next 5 Setup is now installing the driver 3 Go through the readme docu ment for system requirements and installation tips then click Next 6 Click Yes I want to restart this computer now then click Finish Restarting the system will allow the new software installation to take effect ...

Page 47: ...nstall the driver download KU553 Intel Rapid Storage Driver zip file at our website 2 Read the license agree ment and click I accept the terms in the License Agreement Then click Next 1 Setup is ready to install the utility Click Next 3 Go through the readme document to view system requirements and installa tion information then click Next 5 Confirm the installation and click Next 4 Click Next to ...

Page 48: ...www dfi com 48 Chapter 4 Supported Software Chapter 4 6 Click Yes I want to restart this computer now to complete the installation and then click Finish ...

Page 49: ...drive must be the same or larger than the existing drive Settings To enable the RAID function the following settings are required 1 Connect the Serial ATA drive 2 Enable RAID in the Insyde BIOS 3 Create a RAID volume 3 1 Create a RAID volume if the boot type is UEFI 4 Install the Intel Rapid Storage Technology Utility Step 1 Connect the Serial ATA Drive Refer to chapter 2 for details on connecting...

Page 50: ...e boot type enter the Insyde BIOS and go to Boot Boot Type 1 Go to the Advanced menu of the Insyde BIOS and select UEFI Device Manager 2 The screen displays all available drives Select Create RAID volume to create a RAID volume 3 Use the up or down arrow keys to select the RAID level and press Enter 4 Use the up or down arrow keys to scroll through the list of hard drives and press Enter to select...

Page 51: ...id Storage Technology is a utility that allows you to monitor the current status of the SATA drives It enables enhanced performance and power management for the storage subsystem To install the driver download KU553 Intel Rapid Storage Driver zip file at our website Please refer to Chapter 4 for more information ...

Page 52: ...ing when critical software agents are removed Enable Intel AMT in the Insyde BIOS 1 Power on the system then press Del to enter the main menu of the Insyde BIOS 2 In the Advanced menu select Active Management Technology Support 3 Select Enabled in the Intel AMT Support field Active Management Technology Support Intel AMT Support Un Configure ME Advanced F1 Help Select Item F5 F6 Change Values F9 S...

Page 53: ...d menu select MEBX Configuration MEBX Configuration Set ting ACPI Configuration CPU Configuration Video Configuration Audio Configuration SATA Configuration USB Configuration PCI Express Configuration ME Configuration MEBX Configuration Active Management Technology Support Debug Configuration UEFI Device Manager SIO NUVOTON6106D Console Redirection Main Advanced F1 Help Select Item F5 F6 Change Va...

Page 54: ...sion v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved MAIN MENU MEBx Login Intel R ME General Settings Intel R AMT Configuration MEBx Exit Intel R ME Password Move Highlight Enter Select Entry Esc Exit Verify password 7 Select Intel R ME General Settings then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Co...

Page 55: ...ME Password then press Enter Enter the current password in the space provided under Intel R ME Password then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME PLATFORM CONFIGURATION Change ME Password Local FW Update Enabled Intel R ME New Password Move Highlight Enter Select Entry Esc Exi...

Page 56: ... Control Disabled Enabled INTEL R AMT CONFIGURATION Move Highlight Enter Complete Entry Esc Discard Changes 14 In the Intel R AMT Configuration menu select SOL Storage Redirection KVM then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirectio...

Page 57: ... Enabled Disabled Enabled Move Highlight Enter Complete Entry Esc Discard Changes 18 In the SOL Storage Redirection KVM menu select KVM Feature Selection then press Enter Select Enabled or Disabled then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved SOL Storage Redirection KVM Username and passwor...

Page 58: ...er You may choose to use a password only during setup and configuration or to use a pass word anytime the system is being accessed Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved Manageability Feature Selection Enabled SOL Storage Redirection KVM User Consent Password Policy Anytime Network Setup Activate Netw...

Page 59: ...ME SETTINGS Host Name _ Domain Name _ Shared Dedicated FQDN Shared Dynamic DNS Update Disabled 26 Select Domain Name then press Enter Enter the computer s domain name then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME NETWORK NAME SETTINGS Host Name _ Domain Name _ Shared Dedicated FQD...

Page 60: ...ration then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved Move Highlight Enter Select Entry Esc Exit TCP IP SETTINGS Wired LAN IPV4 Configuration Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R ME NET...

Page 61: ... 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete Entry Esc Discard Changes 34 Select Subnet Mask Address then press Enter Enter address then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask ...

Page 62: ...NS Address then press Enter Enter address then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved WIRED LAN IPV4 CONFIGURATION DHCP Mode Disabled IPV4 Address 0 0 0 0 Subnet Mask Address 0 0 0 0 Default Gateway Address 0 0 0 0 Preferred DNS Address 0 0 0 0 Alternate DNS Address 0 0 0 0 Enter Complete ...

Page 63: ...Current Provisioning Mode Provisioning Record Provisioning Server IPV4 IPV6 _ Provisioning Server FQDN _ RCFG TLS PKI Provisioning Mode PKI 42 In the Intel R Remote Setup And Configuration menu select Provisioning Re cord then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R REMOTE SETUP AND...

Page 64: ...the Intel R Remote Setup And Configuration menu Select TLS PKI then press Enter Select Remote Configuration then press Enter Select Enabled or Disabled then press Enter ESC Exit Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R REMOTE CONFIGURATION Remote Configuration Enabled PKI DNS Suffix _ Manage Has...

Page 65: ... to the Intel R AMT Configuration menu select Power Control then press Enter In the Intel R AMT Power Control menu select Intel R AMT ON in Host Sleep States then press Enter Select an option then press Enter Intel R Management Engine BIOS Extension v11 0 0 0010 Intel R ME v11 8 50 3434 Copyright C 2003 16 Intel Corporation All Rights Reserved INTEL R AMT POWER CONTROL Move Highlight Enter Complet...

Page 66: ...the monitor s power switch is on 2 Check that one end of the monitor s power cord is properly attached to the monitor and the other end is plugged into a working AC outlet If necessary try another outlet 3 Check that the video input cable is properly attached to the monitor and the system s display adapter 4 Adjust the brightness of the display by turning the monitor s brightness control knob The ...

Page 67: ...rks by attaching it to a serial port that is working and configured correctly If the serial device does not work either the cable or the serial device has a problem If the serial device works the problem may be due to the onboard I O or the address setting 4 Make sure the COM settings and I O address are configured correctly Keyboard Nothing happens when a key on the keyboard was pressed 1 Make su...

Reviews: