4.10 Still and Motion for all display
This message forces freeze state for all of the displays. This command contains one part; this
part is the command selection.
Command
:
STILLALL
– freeze all display insertion
MOTIONALL
– start all display insertion
4.11 Audio Mute
This message changes audio mute or un-mute state. This command contains two parts. The
command selection is the first part, while method is the last part.
Command
:
AUDIOMUTE
– mute or unmute the audio outputs
Parameter
must between 0 – 1.
0 – unmute; 1 - mute
Sample:
AUDIOMUTE
0
– unmute the audio outputs
4.12 Test Pattern
This message changes the test pattern to be displayed. This command contains two parts. First
part is the command selection; last part is the test pattern id. If this is 0, the current test pattern
will be closed.
Command
:
TESTPATTERN
– open or close the specified test pattern
Parameter
must between 0 – 7.
0 – close; 1 – 7 various test pattern
Sample:
TESTPATTERN
4