NDS3107C Multiplexer User Manual
6
wire and grounding strip should be no less than 25mm
2
.
2.2.5 Device Grounding
Connecting the device’s grounding rod to frame’s grounding pole with copper wire.
2.3 Wire’s Connection
The grounding wire conductive screw is located at the right end of rear panel, and the power
switch, fuse, power supply socket is just beside ,whose order goes like this, power switch is on
the left ,power supply socket is on the right and the fuse is just between them.
Connecting Power Cord
User can insert one end into power supply socket, while insert the other end to AC power.
Connecting Grounding Wire
When the device is solely connected to protective ground, it should adopt independent way,
say, share the same ground with other devices. When the device adopts united way, the
grounding resistance should be smaller than 1
Ω
.
Caution:
Before connecting power cord to NDS3107C multiplexer, user should set the power switch
to “OFF”.
2.4 Signal Cable Connection
The signal connections include the connection of input signal cable and the connection of
output signal cable. The details are as follows:
2.4.1 ASI In and ASI out connection:
ASI Input Connection
User can find ASI input port on the device according to connector mark described in the rear
panel illustration, and then connect the ASI cable (in the accessories). One end is connected to
the Multiplexer’s ASI input port, while the other end is connected to Encoder’s ASI output port
or ASI output port of other equipment.
ASI Output Connection