Page 9
DE-M060304E • DEWE-ORION-1616-10x • Technical Reference Manual • Printing version 1.2.0 • March 19, 2014
DEWE-ORION-1616-10x
DEWE-ORION-1616-10x
1 Introduction
1.1 Key features
16 simultaneous analog inputs (one ADC/channel)
100 kSamples/sec per channel
Four input ranges from ±1.25 V to ±10 V
Single ended inputs with remote sense
Two 32-bit synchronous counter/encoder
16 synchronous digital inputs
8 digital outputs
RS-485 interface
Options:
Two high speed CAN 2.0B controllers
16 additional analog/digital inputs (ORION-3216-100)
8 additional counter/encoder or 32 TTL inputs (ORION-1616-102)
8 additional counter/encoder or 32 inputs adjustable trigger levels (ORION-1616-104)
1.2 How to use the manual
In Chapter one you find an overview about the card-types and possibilities of configurations.
Chapter two explains how to install the card and connect the sensors.
The ADC conversion and the counter-functions are described in chapter three.
All specifications are listed in chapter four.
1.3 Overview
The DEWE-ORION-1616-10x series expands the simultaneous sample A/D-boards from DEWETRON. Even
the standard version offers already 16 analog input channels, two 32-bit counter/encoder inputs and 16
digital inputs - 8 of them can also be used for outputs. The onboard RS-485 interface controls DEWETRON
signal conditioning amplifiers and can directly acquire data from PAD/EPAD series modules.
For guaranteed synchronous data acquisition with the analog inputs, the DEWE-ORION-1616-10x offers 2
high speed CAN interface channels as an option. The boards can be expanded with 16 additional analog or
8 additional 32-bit counter/encoder channels.
Model
Analog input
channels
Max. sampling
rate / channel
Digital input
channels
Digital I/O Ext. Clock Ext. Trigger
Counter
Encoder
TTL
Counter
Encoder
ADJ
CAN
DEWE-ORION-1616-100
16
100 kS/s
2 (8*)
8
1
1
2
-
-
DEWE-ORION-1616-101
16
100 kS/s
2 (8*)
8
1
1
2
-
2
DEWE-ORION-1616-102
16
100 kS/s
10 (40*)
8
1
1
2 + 8
-
-
DEWE-ORION-1616-103
16
100 kS/s
10 (40*)
8
1
1
2 + 8
-
2
DEWE-ORION-1616-104
16
100 kS/s
10 (40*)
8
1
1
2
8
-
DEWE-ORION-1616-105
16
100 kS/s
10 (40*)
8
1
1
2
8
2
DEWE-ORION-3216-100
32
100 kS/s
18 (24*)
8
1
1
2
-
-
DEWE-ORION-3216-101
32
100 kS/s
18 (24*)
8
1
1
2
-
2
* Without using counter inputs
Summary of Contents for DEWE-ORION-1616-10 Series
Page 56: ...C2 Notes...