Main system

Key facts

 

`

Box for connecting up to four DEWE-CAM-GIGE-120  

or DEWE-CAM-GIGE-50-HD cameras to a DEWETRON 

system

 

`

Integrated gigabit Ethernet interface switch

 

`

Small rugged housing for easy integration

 

`

Integrated power supply for up to four cameras

 

`

Real-time data streaming at full resolution

System specifications

DEWE-CAM-GIGE-SPLIT-01

General specifications

Input channels

4 channels for GIGE-120 (up to 120 frames per second in full resolution) or 

GIGE-50-HD cameras

Rated input voltage

9 to 30 V

DC

 (max. 8 to 34 V

DC

)

Remote power supply

Yes (via D-SUB-9 socket)

Power supply for accessories

Yes (12 V

DC

, 1.5 A)

Ethernet interface

8x 10/100/1000 Base-T Ethernet ports

Operating temperature

0 °C (with pre-warmed unit) to +50 °C

Storage temperature

-20 °C to +70 °C

Humidity (operating)

10 % to 80 %, non condensing
5 % to 95 % rel. humidity

Power consumption

Typ. 55 W (four cameras attached)

Dimensions (L x W x H)

318 x 253 x 41.5 mm (12.5 x 9.9 x 1.6 in.) 

Mass

800 g w/o cameras

Connector overview

Power supply input

2-pin LEMO EGJ.2B.302

Power supply output (12 V

DC

, 1.5 A) 2-pin LEMO EGG.1B.302

Camera TRG / POW

5-pin LEMO EGG.1B.305 (4x)

Remote power input connector

Male D-SUB-9

Ethernet

RJ-45 (8x)

Requirements

GBit LAN interface in base unit
Min. Intel® Core™ i5 CPU and 3 GB RAM in base unit
OXYGEN software and OXY-OPT-CAM-GIGE plugin

Tab. 1: System specifications DEWE-CAM-GIGE-SPLIT-01

Summary of Contents for DEWE-CAM-GIGE-SPLIT-01

Page 1: ...ill supply you with accurate complete and reproducible measurement results for your decision making Look forward to the easy handling and the flexible and modular use of your DEWETRON product and draw...

Page 2: ...protected by copyright All rights are reserved Reproduction adaptation or translation without prior written permission is prohibited except as allowed under the copyright laws All trademarks and regis...

Page 3: ...structions that must be observed by the user Fault less operation can only be guaranteed by observing these instructions Intended use This product is used for connecting up to 4 DEWE CAM GIGE 120 or D...

Page 4: ...Preface 4 Notes...

Page 5: ...erations 11 Problematic network stacks 11 Warranty information 11 Legal information 11 Restricted rights legend 11 Legal disclaimer 11 Printing history 12 Main system 13 Key facts 13 System specificat...

Page 6: ...TABLE OF CONTENTS 6 Notes...

Page 7: ...age in adverse environmental the system has been exposed to heavy shipment strain The warranty is void if damages caused by disregarding this manual For consequential damages NO liability will be assu...

Page 8: ...only except for DC systems DO NOT touch any exposed connectors or components if they are live wired The use of metal bare wires is not allowed There is a risk of short circuits and fire hazard The as...

Page 9: ...the user has to consider the security advices and warn ings in this manual EN 61326 3 1 2008 IEC 61326 1 applies to this part of IEC 61326 but is limited to systems and equipment for industrial applic...

Page 10: ...n on the product refer to the technical reference manual ISO 7000 4034 2004 01 Indicates hazardous voltages Observe precautions for handling electrostatic sensitive devices Indicates the chassis termi...

Page 11: ...d is outside the scope of the 2011 65 EU RoHS Directive This product is known to contain lead Problematic network stacks Often intrusive IT software or network processes can interfere with the primary...

Page 12: ...onnection with the furnishing of this document or the use of the information in this document Printing history Refer to the page bottom for printing version Copyright DEWETRON GmbH This document conta...

Page 13: ...ower supply Yes via D SUB 9 socket Power supply for accessories Yes 12 VDC 1 5 A Ethernet interface 8x 10 100 1000 Base T Ethernet ports Operating temperature 0 C with pre warmed unit to 50 C Storage...

Page 14: ...Box comes with an integrated power supply for up to four cameras 9 30 VDC including the possibility to remotely power on the box via a 9 pin DSUB socket The DEWE CAM GIGE SPLIT 01 box usually could b...

Page 15: ...unction with the 9 pin D SUB connector TRG In Remote On connector and a remote on voltage between 4 5 12 5 VDC the DEWE CAM GIGE SPLIT 01 box can be powered on remotely Switch position ON Device is sw...

Page 16: ...ghts Indicates neither Power 1 nor 2 is active OFF No failure 9 GBit LAN interface con nectors The DEWE CAM GIGE SPLIT 01 box supports 10 100 1000 BaseT Ethernet with standard RJ45 connector LED Color...

Page 17: ...x 480 90 105 4 640 x 240 180 105 Tab 3 DEWE CAM GIGE 120 frame rates at different AoI DEWE CAM GIGE 50 HD frame rates at different AoI DEWE CAM GIGE 50 HD AoI area of interest with OXYGEN software rel...

Page 18: ...SLPIT 01 camera split box is designed to be used with any DEWETRON instrument but especially with a DEWE2 DEWE3 A4 M4 system the camera split box fits perfectly underneath Fig 4 shows a DEWE2 A4 on a...

Page 19: ...le 20 A ATO fuse INFORMATION The fuse has to be replaced by the same type Updates Software updates NOTICE The system BIOS is protected by password Any change in the BIOS may cause a system crash When...

Page 20: ...t you if you have any questions or any technical difficulties regarding the system For any support contact your local distributor first or DEWETRON directly For Asia and Europe contact For the America...

Page 21: ...future INFORMATION Only the team of DEWETRON is allowed to perform any kinds of repairs to your system to assure a safe and proper operation in future For information regarding service and repairs co...

Page 22: ...Notes Maintenance and service 22...

Page 23: ...f the Council of 26 February 2014 on the harmo nization of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage...

Page 24: ...Certificate of conformity 24 Notes...

Reviews: