4.2.3. Connecting to existing DEWETRON systems
The DS-CAM-120c is also compatible with existing DEWETRON systems.
Please consider the system requirements:
●
see chapter System requirements
●
DEWETRON instruments must not have DI-ISO option (isolated inputs/outputs)! In this case
clocking is not possible, only free-run (the CLK pin is not available on the connector).
Free-run operation (without clocking, for low framerates) is easy, just connect the camera to the GigE
LAN port.
If you want to trigger the camera, you have to use a special cable for the trigger/clock line. Usually every
DEWETRON instrument is equipped with a 37pin DSUB connector, please see DEWETRON manual for
pinout, here for example is the pinout for the Orion-1622-100 (see Reference List (b)).
●
Connect EXT_CLK1 (pin 17) to the CLK of the Lemo 00 connector of the camera (pin 3).
●
Connect DGND (pin 37) to GND of the Lemo 00 connector (pin 4)
●
Set the pin EXT_CLK1 to “Video” in DEWESoft hardware setup
Illustration 5: DEWETRON Orion-1622-100 DSUB 37 pinout