background image

English

English

8

9

Power and Fault Indicators on 

the LCD Display

Indicates that the unit is connected 

properly and is ready to use. The AC 

outlet icon and USB icon will light solid 

and the Digital Readout shows “0W”. 

The bars on the Battery Icon represent 

the voltage level of the connected power 

source.
Indicates that the unit is functioning 

normally. The AC outlet icon and USB 

icon will light solid and the Digital 

Readout shows the total output wattage 

of AC outlets. The bars on the Battery 

Icon represent the voltage level of the 

connected power source.
This indicates an input voltage too low 

fault condition. The fault icon and the 

empty battery icon will light solid and 

the unit will emit three beeps every five 

seconds. Refer to the following section 

for an explanation.
This indicates an input voltage too high 

fault condition. The fault icon and the full 

battery icon will light solid and the unit 

will emit three beeps every five seconds. 

Refer to the following section for an 

explanation.

This indicates a thermal fault condition. 

The fault icon and the overheat icon will 

light solid and the bars on the Battery 

Icon represent the voltage level of the 

connected power source. The unit will 

emit three beeps every five seconds. 

Refer to the following section for an 

explanation.
This indicates a USB fault condition, and 

displays when the USB load exceeds 

capacity. The USB icon will flash and the 

Digital Readout shows the total output 

wattage of AC outlets. The fault icon and 

the AC outlet icon will light solid and the 

bars on the Battery Icon represent the 

voltage level of the connected power 

source. The unit will emit three beeps 

every five seconds.
This indicates an overload or short circuit 

fault condition. The AC outlet icon will 

flash and the Digital Readout shows 

0W. The fault icon and the USB icon will 

light solid and the bars on the Battery 

Icon represent the voltage level of the 

connected power source. The unit will 

emit three beeps every five seconds. 

Refer to the following section for an 

explanation.

Power Source Requirements

Your inverter will operate from input voltages between 11 and 15 volts 

DC. If the input voltage drops below 10 volts DC, the inverter will 

shut down. This feature protects the battery from being completely 

discharged.
The inverter will also shut down if the input voltage exceeds 15.6 volts. 

This protects the inverter against excessive input voltage. Although 

the inverter has built-in protection against over voltage, it may still be 

damaged if the input voltage exceeds 15 volts.
Your inverter is engineered to have standard electrical and electronic 

equipment directly connected to it in the manner described in the 

“Installation” section of this Instruction Manual. Do not connect the 

inverter to household or RV AC distribution wiring. Do not connect 

the inverter to any AC load circuit in which the neutral conductor is 

connected to ground (earth) or to the negative of the DC (battery) 

power source.
Inductive loads, such as TVs and stereos, require more current to 

operate than resistive loads of the same wattage rating. Induction 

motors, as well as some TVs, may require two to six times their rated 

wattage to start up. Because these inverters have a peak watt power 

rating, many such appliances and tools may be safely operated. The 

equipment that needs the highest starting wattage are pumps and 

compressors that start under load. This equipment can be safely tested. 

If an overload is detected, the inverter will simply shut down until the 

overload situation is corrected. Use the power button to turn off the 

inverter, then on again to reset it.

CAUTIONS

• Exceeding recommended voltage limits will void manufacturer’s 

warranty.

• NEVER try to use your inverter with any 12 volt DC power source 

that uses a positive ground. (Most vehicles and boats use negative 

ground systems.)

• The Power Inverter must be connected only to batteries with a 

nominal output voltage of 12 volts. The unit will not operate from a 

6 volt battery and will sustain permanent damage if connected to a 

24 volt battery.

• Reverse polarity connection will result in a blown fuse and may cause 

permanent damage to the inverter.

Protective Features

The inverter monitors the following conditions:

Input Voltage Too Low:

 This condition is not harmful to the inverter, 

but could damage the power source, so the inverter will automatically 

shut down when input voltage drops below 10.5 ± 0.5 volts DC.

Input Voltage Too High: 

The inverter will automatically shut down 

when DC input voltage exceeds 16 ± 0.5 volts, as this can harm the 

unit.

Thermal Shutdown Protection:

 The inverter will automatically shut 

down when the unit becomes overheated.

Overload/Short Circuit Protection:

 The inverter will automatically 

shut down when an overload or short circuit occurs.
Refer to “Power and Fault Indicators on the LCD Display” for an 

explanation of the icons that indicate a fault condition before shutdown. 

To restart the unit, simply unplug all devices plugged into the inverter; 

disconnect the inverter from any 12 volt DC power source; then 

reconnect the inverter BEFORE plugging the appliance(s) back in.

DXAEPI1000_ManualENSP_080320.indd   8-9

DXAEPI1000_ManualENSP_080320.indd   8-9

8/3/2020   1:40:37 PM

8/3/2020   1:40:37 PM

Summary of Contents for DXAEPI1000

Page 1: ...os INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES If you have questions or comments contact us Si tiene dudas o comentarios contáctenos 1 888 394 3392 RD080320 DXAEPI1000_ManualENSP_080320 indd 32 1 DXAEPI1000_ManualENSP_080320 indd 32 1 8 3 2020 1 40 35 PM 8 3 2020 1 40 35 PM ...

Page 2: ...or damaged parts Any part that is damaged should be properly repaired or replaced by manufacturer unless otherwise indicated elsewhere in this instruction manual before further use Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain ...

Page 3: ...ding electronic device to confirm that it can be used with this type of USB Port Specific Safety Instructions for Inverters WARNING To reduce the risk of electric shock Do not connect to AC distribution wiring Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED This includes DC cigarette lighter type plug connection This unit is NOT approved for ignit...

Page 4: ...ts 120 to determine the wattage Resistive loads are the easiest for the inverter to run however it will not run larger resistive loads such as electric stoves and heaters which require far more wattage than the inverter can deliver Inductive loads such as TVs and stereos require more current to operate than do resistive loads of the same wattage rating WARNING If the product does not operate norma...

Page 5: ...put voltage exceeds 15 volts Your inverter is engineered to have standard electrical and electronic equipment directly connected to it in the manner described in the Installation section of this Instruction Manual Do not connect the inverter to household or RV AC distribution wiring Do not connect the inverter to any AC load circuit in which the neutral conductor is connected to ground earth or to...

Page 6: ...tive slide in connector at the end of the supplied red cable set into the groove of the positive cable post Replace the cap and turn clockwise to secure Do not over tighten 11 Turn the black plastic cap on the inverter s negative cable post counterclockwise and remove Attach the negative slide in Installation Your inverter will provide you with continuous electrical power when powered by a reliabl...

Page 7: ...f a fault icon appears refer to the Protective Features section and the Troubleshooting section of this manual 14 Test the inverter by turning it on and plugging in a 100 watt lamp or equipment If the inverter is not operating properly then rrefer to the Protective Features section and the Troubleshooting section of this manual CAUTIONS The cable and fuse sizes given here are a general recommendat...

Page 8: ... instructions for care and maintenance for the product This warranty gives you the original retail purchaser specific legal rights and you may have other rights which vary in certain states or provinces This product is not intended for commercial use 90 DAY REFUND POLICY If you are not completely satisfied with the performance of this product for any reason you can return it within ninety 90 days ...

Page 9: ...ios es un DeWalt inversor de potencia de 1000W configurado para suministrar potencia continua en forma de dos tomacorrientes de 120 voltios CA y tres puertos de alimentación USB de 5 voltios para ejecutar la mayoría de los hogares o aparatos electrónicos Instrucciones importantes sobre seguridad 1 Conserve estas instrucciones 2 Preste atención a todas las advertencias 3 Obedezca todas las adverten...

Page 10: ...correctamente es posible que lo indique el manual de instrucciones de su producto En caso de duda debe comunicarse con el fabricante de su producto ANTES DE UTILIZARLO 11 El aparato no quedará expuesto a goteos ni a salpicaduras y no se colocarán sobre el aparato objetos llenos de líquido tales como jarrones LEA TODAS LAS INSTRUCCIONES Instrucciones de seguridad específicas para los inversores ADV...

Page 11: ...e uso doméstico o un inversor de onda senoidal pura para poder funcionar correctamente Este inversor puede dañar su producto si éste contiene Fuentes de alimentación controladas por microprocesador Cargadores de baterías sin transformador Fuentes de energía con acoplamiento capacitivo Si se utiliza un producto incompatible con este inversor Es posible que el producto no funcione en absoluto sin in...

Page 12: ...oltaje de entrada excede los 15 voltios Su inversor está diseñado para tener equipos eléctricos y electrónicos estándar conectados directamente a él de la manera descrita en la sección Instalación de este manual de instrucciones No conecte el Inversor eléctrico a cableados de distribución de CA de vehículos recreativos o para uso doméstico No conecte el inversor a cualquier circuito de carga de CA...

Page 13: ...entes en el área de instalación 2 Identifique los terminales positivo y negativo batería de la fuente de energía de cd Esto indica una condición de la sobrecarga o de avería del cortocircuito El icono de la toma de CA parpadea y la lectura digital muestra 0W El icono de fallo y el icono USB se iluminará sólida y las barras en el icono de la batería representar el nivel de voltaje de la fuente de a...

Page 14: ... un lado de la negativa fuente de alimentación de CC batería terminal Conecte el otro extremo del cable al terminal negativo negro Junta tórica del conjunto del cable suministrado asegurándolos con el tornillo suministrado la arandela y las tuercas de mariposa 6 Conecte una prolongación corta del cable al otro terminal del soporte del fusible o al interruptor automático Márquelo como positivo o 7 ...

Page 15: ...mas Problemas específicos de salida de CA Cuando se utilizan las tomas de CA de 120V la unidad supervisará las siguientes condiciones de falla fallo térmico fallo de voltaje de batería bajo y alto sobrecarga y cortocircuito consulte la sección Características de protección Problema Solución posible Si existe una condición de fallo en cualquiera de los tomacorrientes CA la pantalla LCD mostrará la ...

Page 16: ... puede ser requerida por el fabricante 2 Devuelva el producto a la tienda donde el producto fue comprado para un intercambio siempre y cuando se trate de un minorista participante Devoluciones al minorista deben hacerse dentro del plazo de póliza de devoluciones del minorista para intercambios solamente por lo general 30 a 90 días después de la fecha de compra La prueba de compra puede ser requeri...

Reviews: