12
English
MOVING
When moving the compressor, grasp the handle and carry the
compressor as close to the body as possible.
WARNING: Risk of unsafe operation. Ensure proper footing and
use caution when carrying compressor to avoid a loss of balance.
PREPARATION FOR USE
Pre-Start Checklist (Fig. 1)
1. Ensure the On/Off switch (A) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle.
See
Voltage and Circuit Protection under Installation.
3. Ensure air tank is drained, see
Draining Air Tank under
Maintenance.
4. Ensure the drain valve (G) is closed.
5. Ensure safety valve (F) is functioning properly, see
Checking
Safety Valve under Maintenance.
6. Turn regulator knob (D) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 psi.
7. Visually inspect air hose, replace if needed.
8. Attach hose and accessories.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use damaged or
worn accessories.
WARNING: Risk of bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
OPERATING PROCEDURES
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
Start-up (Fig. 1)
1. Follow
Pre-Start Checklist under Preparation for Use.
2. Move the On/Off switch to the ON position and allow tank
pressure to build. Motor will stop when tank pressure reaches
cut-out pressure.
CAUTION: Risk of unsafe operation. Compressed air from the
unit may contain wa ter condensation. Do not spray un fil tered air
at an item that could be damaged by moisture. Some air op er ated
tools or de vic es may require filtered air. Read the in struc tions for
the air tool or device.
3. Adjust regulator (D) to desired setting. See
Regulator under
Features.
Shut-down (Fig. 1)
1. Move On/Off switch (A) to the OFF position.
NOTE: If finished
using compressor, follow Steps 2–6.
NOTE: When the unit has been turned off, it is normal to hear a short
hiss of air being released.
2. Turn regulator knob (D) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 psi.
3. Remove hose and accessory.
NOTE: Always turn off and unplug unit when not in use.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see
Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will