english
51
WARnInG:
Since accessories, other than those offered
by
D
e
WALT
, have not been tested with this product, use
of such accessories with this tool could be hazardous.
To reduce the risk of injury, only
D
e
WALT
, recommended
accessories should be used with this product.
If you need assistance in locating any accessory, please contact your
local
D
e
WALT
authorised service center.
DAnGER:
To reduce the risk of serious personal injury,
never stare directly into the laser beam, with or without
safety glasses.
troubleshooting
If measurement conditions do not permit an accurate measurement,
an error code will appear on the LCD display. For an error code
description refer to the following table.
Code
Description
Correction
204
Calculation error
Repeat the measurement
252
LDM too hot
Let the LDM cool down
253
LDM too cold
Warm the LDM up
255
Weak signal
Change the target surface (e.g.,
put white paper on glass door)
256
Incorrect reading
Change the target surface (e.g.,
put white paper on glass door)
257
Too much
background light
Shadow the target area
258
Outside of range
Stay within the working range
260
Laser beam interrupted
Repeat the measurement