Product overview
devolo G3-PLC Modem 500k
10
Line connections
This is where you connect the conductors to the corresponding line connections:
Single-phase connection
: the external conductor is connected to the
L1
terminal. The
neutral conductor is connected to the
N
terminal.
Three-phase connection
: one external conductor each is connected to the
L1
,
L2
and
L3 terminals.
The neutral conductor is also connected to the
N
terminal.
The permitted
conductor cross-section
for the connection to the terminals is
1.5 mm²
to 6 mm²
.
Indicator lights
The indicator lights (LEDs) show all of the statuses for the G3-PLC Modem 500k by
illuminating and/or flashing in different ways. The status and LED behaviour of the de-
vice is summarised in the following table:
Reset button
You can use a pointed object to press the reset button. It has two different func-
tions:
쎲
The device restarts if you press the
Reset
button for less than 15 seconds.
쎲
To change the configuration of the G3-PLC Modem 500k back to the
factory
default
, press the
Reset
button
for more than 15 seconds
(until all of the LEDs go
out).
Keep in mind that ALL settings that have already been made will be lost and
the device may no longer connect with the network automatically!
Status
Power LED
PLC link LED
Indicator LED
Power: Off
Off
Off
Off
Self-test
Orange
쒁
Off
Orange
쒁
Off
Orange
쒁
Off
Start-up process
orange
Off
Off
Started
(PAN client = no PAN/
PAN coordinator = con-
flict)
green
orange
Off
G3 operating mode
green
green
green
G3 modem error/G3
firmware update
green
orange
orange
Factory default
Orange
쒁
Off
Orange
쒁
Off
Orange
쒁
Off
Reset
Off
Off
Off