background image

 

Item No. 

Part Number 

Description 

Q

ty 

Remarks 

T2AG-368 

Retaining Ring 

with Cap Seat and Ring Gasket 

T2AG-50-K5 

Cap Seat 

5 pieces 

T2AG-55-K5 

Ring 

Gasket

 

5 pieces 

Refer to Chart1 

Air Cap 

 

Refer to Chart2 

Fluid Tip 

 

T2AG-10 

Needle Seal Kit 

 

T2AG-102 

Piston Seal 

 

Refer to Chart2 

Needle 

 

T2AG-106 

Needle Spring 

 

10 

T2AG-500 

Rear Body(Fixed type) 

 

11 

T2AG-600 

Rear Body(Adjustable type) 

 

12 

T2AG-140 

O-Ring (Small) S4   

2 for fluid, 1for air 

13 

T2AG-130 

O-Ring (Big) S6 

for air 

14 

T2AG-100AL 

T2AG-100SS 

Manifold (Aluminum) 

Manifold (SUS) 

 

15 

-------- 

Hexagon Socket Bolt M6

×

L25 

Commercial product 

16 

-------- 

Plug 1/8 

Commercial product 

17 

T2AG-STU-64 

Joint for Fluid 

with Fluid Seal 

18 

EC6-R1/8A-M-R1001 

Joint for Air 

 

19 

T2AG-TU-1-K5 

Fluid Seal Kit of 5 

 

 

 

 

 

 

 

T2AG-3-K 

Mounting Stud Kit 

 

Optional 

 

T-AGPZ-34 

Specialized Tool for Needle Seal Kit 

 

Optional (Refer to Figure 5.) 

 

T2AG-700 

Rear Body(Adjustable type with scale) 

 

Optional (Refer to Figure 5.) 

 

Summary of Contents for T2AGPV LVMP Series

Page 1: ...Shape Typical Applications Marking Part Number 805MT2 AV 1239 805MT2 G 0 7 FX 1 1 FF 1 4 FW 1 6 E 1 8 220mm Blunt Most conventional materials Waterborne 807MT2 AV 1239 807MT2 G 0 7 FX 1 1 FF 1 4 FW 1...

Page 2: ...edle Lapped Set 805MT2 807MT2 G 0 7 T2AG 440 G FX 1 1 T2AG 440 FX FF 1 4 T2AG 440 FF E 1 8 T2AG 440 E 805MT2 807MT2 G 0 7 FX 1 1 FF 1 4 FF 1 6 Fluid Tip Needle T2AG 4S G T2AG 4S FX T2AG 4S FF T2AG 4S...

Page 3: ...olvents for cleaning Those used for equipment flushing must have a flash point equal to or greater than that of the coating Those used for general cleaning must have flash points above 100 F 37 8 C In...

Page 4: ...f actual noise levels produced by the various air cap nozzle set ups are available on request Wear earplugs when using the spray gun Spraying solvent Pressured air fluid passage may be broken when cle...

Page 5: ...ressure Min 0 34MPa 3 5 kgf cm2 Max 0 49MPa 5 0 kgf cm2 Weight 730g SUS Adjustable type Type for Non Circulation 336g Aluminum Adjustable type Type for Non Circulation Mounting Stud Dia 19mm x 51mm Fl...

Page 6: ...the cleaning procedure and before replacing any parts Follow the procedures in the literature provided with the system CLEANING 1 Please follow the instruction manual for the pressure tank or the fee...

Page 7: ...ers 2 Insert the new Needle Assy and install the Spring and Rear Body 3 Piston Seal should not be reused because it would be damaged when removed Replacing Needle Seal Kit 6 1 Remove Rear Body 10or11...

Page 8: ...1 T2AG 600 Rear Body Adjustable type 1 12 T2AG 140 O Ring Small S4 3 2 for fluid 1for air 13 T2AG 130 O Ring Big S6 2 for air 14 T2AG 100AL T2AG 100SS Manifold Aluminum Manifold SUS 1 15 Hexagon Socke...

Page 9: ...or clear obstruction 2 Clean 3 Replace or tighten 4 Tighten or replace Air leaking from the center hole of Rear Body Damaged or worn Piston Seal 7 Damaged cylinder part of the gun body Replace Gun bo...