SAFETY PRECAUTIONS

 

This manual contains important information that ALL users should know and understand BEFORE using this equipment. This 

information relates to USER SAFETY and PREVENTING EQUIPMENT PROBLEMS. 

To help you recognize this information, we use the following terms to draw your attention to certain  equipment labels and 

portions of this manual. Pay special attention to any label or information that is highlighted by one of these terms: 

WARNING 

Important information to alert you to a situation that might cause serious injury or loss of life if instructions 

are not followed. 

CAUTION 

Important information that tells how to prevent damage to equipment. 

NOTE 

Information that you should pay special attention to. 

 

WARNING 

The following hazards may occur during the normal use of this equipment. Please read the following chart. 

HAZARD 

CAUSE 

SAFEGUARDS 

Fire 

 

Solvents and coatings can be highly

 

flammable or combustible, especially

 

when sprayed. 

1.  Adequate exhaust must be provided to keep 

the

 

air free of accumulations of flammable 

vapors. 

2.  Smoking must never be allowed in the spray 

area. 

3.  Fire extinguishing equipment must be 

present in the spray area. 

4.  Static discharges must be prevented. 

Ground(earth) all conductive objects in the 

spray area, such as a cleaning solvent 

bucket, fire extinguisher, etc. 

5.  When using solvents for cleaning: 

 

Those used for equipment flushing must 

have a flash point equal to or greater than 

that of the coating. 

 

Those used for general cleaning must 

have flash points above 100°F (37.8°C). 

Inhaling Toxic Substances 

 

Certain materials may be harmful if 

inhaled or if there is contact with the 

skin. 

1.  Follow the requirements of the Material 

Safety Data Sheet supplied by coating 

material manufacturer. 

2.  Adequate exhaust must be provided to keep 

the air free of accumulations of toxic 

materials. 

3.  Use a mask or respirator whenever there is a 

chance of inhaling sprayed materials. The 

mask must be compatible with the material 

being sprayed and its concentration. 

Equipment must be as prescribed by an 

industrial hygienist or safety expert, and be 

NIOSH approved. 

Explosion Hazard – 

Incompatible Materials 

 

Halogenated hydrocarbon Solvents- 

for example: 

methylene chloride and 

1,1,1,-Trichloroethane are not 

chemically compatible with the 

aluminum that might be used in 

many system components. The 

chemical reaction caused by these 

solvents reacting with aluminum can 

become violent and lead to an 

equipment explosion. 

The T-AGB spray gun can be used with these 

solvents.   

However, aluminum is widely used in other 

spray application equipment – such as material 

pumps, cups, regulators, valves, etc. Check all 

other equipment items before use of these 

solvents. Read the label or data sheet for the 

material you intend to spray. If in doubt as to 

where or not a coating or cleaning material is 

compatible, contact your material supplier. 

Summary of Contents for T2AGPV LVMP Series

Page 1: ...Shape Typical Applications Marking Part Number 805MT2 AV 1239 805MT2 G 0 7 FX 1 1 FF 1 4 FW 1 6 E 1 8 220mm Blunt Most conventional materials Waterborne 807MT2 AV 1239 807MT2 G 0 7 FX 1 1 FF 1 4 FW 1...

Page 2: ...edle Lapped Set 805MT2 807MT2 G 0 7 T2AG 440 G FX 1 1 T2AG 440 FX FF 1 4 T2AG 440 FF E 1 8 T2AG 440 E 805MT2 807MT2 G 0 7 FX 1 1 FF 1 4 FF 1 6 Fluid Tip Needle T2AG 4S G T2AG 4S FX T2AG 4S FF T2AG 4S...

Page 3: ...olvents for cleaning Those used for equipment flushing must have a flash point equal to or greater than that of the coating Those used for general cleaning must have flash points above 100 F 37 8 C In...

Page 4: ...f actual noise levels produced by the various air cap nozzle set ups are available on request Wear earplugs when using the spray gun Spraying solvent Pressured air fluid passage may be broken when cle...

Page 5: ...ressure Min 0 34MPa 3 5 kgf cm2 Max 0 49MPa 5 0 kgf cm2 Weight 730g SUS Adjustable type Type for Non Circulation 336g Aluminum Adjustable type Type for Non Circulation Mounting Stud Dia 19mm x 51mm Fl...

Page 6: ...the cleaning procedure and before replacing any parts Follow the procedures in the literature provided with the system CLEANING 1 Please follow the instruction manual for the pressure tank or the fee...

Page 7: ...ers 2 Insert the new Needle Assy and install the Spring and Rear Body 3 Piston Seal should not be reused because it would be damaged when removed Replacing Needle Seal Kit 6 1 Remove Rear Body 10or11...

Page 8: ...1 T2AG 600 Rear Body Adjustable type 1 12 T2AG 140 O Ring Small S4 3 2 for fluid 1for air 13 T2AG 130 O Ring Big S6 2 for air 14 T2AG 100AL T2AG 100SS Manifold Aluminum Manifold SUS 1 15 Hexagon Socke...

Page 9: ...or clear obstruction 2 Clean 3 Replace or tighten 4 Tighten or replace Air leaking from the center hole of Rear Body Damaged or worn Piston Seal 7 Damaged cylinder part of the gun body Replace Gun bo...