background image

REPLACEMENT 

Tools Required 

  Crescent Wrench 

  10mm or 13mm Box Wrench 

  Pliers (for Needle Assy) 

  Open Wrench 

  Hex Wrench 

Fluid Tip (5) 

1. Relieve all air and fluid pressure in system. 
2. Remove Rear Body (10or11), Needle Spring (9). Pull Needle Assy (8) out from gun body with Pliers. 
3. Remove Retaining Ring (1) and Air Cap (4). 
4. Remove Fluid Tip (5) with 1/2 Box Wrench. 
5. Reassemble in reverse order. Recommended torque of Fluid Tip (5): 16~20N

m. 

Replacing Needle Assy (8), Piston Seal (7) 

1. Remove Rear Body (10or11), Needle Spring (9). Pull Needle Assy (8) out from gun body with Pliers. 
2. Insert the new Needle Assy and install the Spring and Rear Body. 
3. Piston Seal should not be reused because it would be damaged when removed. 

 

Replacing Needle Seal Kit (6) 

1.  Remove Rear Body (10or11), Needle Spring (9). Pull Needle Assy (8) out from gun body with Pliers. 

2.  Remove Needle Seal Kit (6) with 13mm Box Wrench or specialized tool (Optional). 

3.  Attach new Needle Seal Kit (6) to the gun body with the 13mm Box Wrench or specialized tool (Optional). Before doing it 

please apply a little bit of vaseline to the O-ring of the Seal Kit. 

4.  Before inserting to the gun, apply vaseline to the Piston Seal (7) of Needle Assay (8). 

5.  Insert Needle Spring (9), and assemble Rear Body. 

6.  Pressure 0.35Mpa on CYL and check the movement of needle. 

 

 

Figure 5. Gun Exploded View 

 

Summary of Contents for T2AGPV LVMP Series

Page 1: ...Shape Typical Applications Marking Part Number 805MT2 AV 1239 805MT2 G 0 7 FX 1 1 FF 1 4 FW 1 6 E 1 8 220mm Blunt Most conventional materials Waterborne 807MT2 AV 1239 807MT2 G 0 7 FX 1 1 FF 1 4 FW 1...

Page 2: ...edle Lapped Set 805MT2 807MT2 G 0 7 T2AG 440 G FX 1 1 T2AG 440 FX FF 1 4 T2AG 440 FF E 1 8 T2AG 440 E 805MT2 807MT2 G 0 7 FX 1 1 FF 1 4 FF 1 6 Fluid Tip Needle T2AG 4S G T2AG 4S FX T2AG 4S FF T2AG 4S...

Page 3: ...olvents for cleaning Those used for equipment flushing must have a flash point equal to or greater than that of the coating Those used for general cleaning must have flash points above 100 F 37 8 C In...

Page 4: ...f actual noise levels produced by the various air cap nozzle set ups are available on request Wear earplugs when using the spray gun Spraying solvent Pressured air fluid passage may be broken when cle...

Page 5: ...ressure Min 0 34MPa 3 5 kgf cm2 Max 0 49MPa 5 0 kgf cm2 Weight 730g SUS Adjustable type Type for Non Circulation 336g Aluminum Adjustable type Type for Non Circulation Mounting Stud Dia 19mm x 51mm Fl...

Page 6: ...the cleaning procedure and before replacing any parts Follow the procedures in the literature provided with the system CLEANING 1 Please follow the instruction manual for the pressure tank or the fee...

Page 7: ...ers 2 Insert the new Needle Assy and install the Spring and Rear Body 3 Piston Seal should not be reused because it would be damaged when removed Replacing Needle Seal Kit 6 1 Remove Rear Body 10or11...

Page 8: ...1 T2AG 600 Rear Body Adjustable type 1 12 T2AG 140 O Ring Small S4 3 2 for fluid 1for air 13 T2AG 130 O Ring Big S6 2 for air 14 T2AG 100AL T2AG 100SS Manifold Aluminum Manifold SUS 1 15 Hexagon Socke...

Page 9: ...or clear obstruction 2 Clean 3 Replace or tighten 4 Tighten or replace Air leaking from the center hole of Rear Body Damaged or worn Piston Seal 7 Damaged cylinder part of the gun body Replace Gun bo...

Reviews: