Voltage and Circuit Protection

Refer to your Parts Manual for voltage and circuit protection
requirements of your compressor. Use only a fuse or circuit
breaker that is the same rating as the branch circuit the air
compressor is operated on. If the compressor is connected to
a circuit protected by fuses, use only dual element time delay
fuses, as noted in the Parts Manual.

Certain air compressors can be converted from
120V to 240V operation. When converting an
air compressor to 240V operation, the
attached three-prong 120V cord assembly
must be replaced with a three-pronged 240V
cord assembly that can be purchased through
an Authorized Warranty Service Center. To
locate an Authorized Warranty Service Center
nearest you, call us at 1-800-888-2468, Ext.
2, then 2.

Some models have a dual voltage motor, 120 and 240 volt.
They are wired for 120 volt but can be converted to 240 volt
operation. Instructions for connecting the motor for operation
at 240 volt can be found printed on the label attached to the
side of the motor.

Certain air compressor models can be operated
on a 15 amp circuit if:
1. Voltage supply to circuit is normal.
2. Circuit is not used to supply any other

electrical needs (lights, appliances, etc.)

3. Extension cords comply with specifications

in this manual.

4. Circuit is equipped with a 15 amp circuit

breaker or 15 amp time delay fuse.

Extension Cords

To avoid voltage drop and power loss to the motor, and to
prevent overheating, use extra air hose instead of an exten-
sion cord.

If an extension cord 

must

 be used:

• use only a 3-wire extension cord that has a 3-blade ground-

ing plug and a 3-slot receptacle that will accept the plug on
the extension cord.

• make sure the extension cord is in good condition.
• the extension cord should be no longer than 50 feet.
• the minimum wire size is 12 gauge (AWG). (Wire size in-

creases as gauge number decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE 14 AWG or 16 AWG.)

Lubrication and Oil

Multi-Viscosity motor oils, like 10W 30, should not be
used in an air compressor. They leave carbon depos-
its on critical components, thus reducing perfor-
mance and compressor life. Use air compressor oil
only.

Compressors are shipped without oil.  A small amount
of oil may be present in the pump upon receipt of the
air compressor. This is due to plant testing and does
not mean that the pump contains oil. Do not attempt
to operate this air compressor without first adding oil
to the crankcase. Serious damage can result from
even limited operation unless filled with oil and bro-
ken in correctly. Make sure to closely follow initial
start-up procedures.

Place unit on a level surface. Remove oil fill plug and slowly
add a compressor oil such as Castrol Heavy Duty 30 weight
until it is even with the top of the oil fill hole. (It must not be
allowed to be lower than 3/8" -- 6 threads down -- from the
top at any time.) When filling the crankcase, the oil flows very
slowly into the pump. If the oil is added too quickly, it will
overflow and appear to be full. 

Crankcase oil capacity is 16

fluid ounces.

 Replace oil fill plug.

NOTE

Drain and refill the compressor pump crank-
case after the first 100 hours of operation.

GROUNDING  INSTRUCTIONS

RISK OF ELECTRICAL SHOCK! In the event of a
short circuit, grounding reduces the risk of
shock by providing an escape wire for the
electric current. This air compressor must be
properly grounded.

The air compressor is equipped with a cord having a ground-
ing wire with an appropriate grounding plug. The plug must be
used with an outlet that has been installed and grounded in
accordance with all local codes and ordinances. The outlet
must have the same configuration as the plug. See illustra-
tion. 

DO NOT USE AN ADAPTER.

Inspect the plug and cord before each use. Do not use if

there are signs of damage.

IMPROPER GROUNDING CAN RESULT IN ELEC-
TRICAL SHOCK.

Do not modify the plug that has been provided. If it does not
fit the available outlet, the correct outlet should be installed
by a qualified electrician.

If repairing or replacing cord or plug, the grounding wire must
be kept separate from the current-carrying wires. Never
connect the grounding wire to a flat blade plug terminal. The
grounding wire has insulation with an outer surface that is
green - with or without yellow stripes.

If these grounding instructions are not completely under-
stood, or if in doubt as to whether the compressor is properly
grounded, have the installation checked by a qualified elec-
trician.

Summary of Contents for MG3-OLPORT-3A

Page 1: ...he following information Model number of your compressor Part number and description of the item you wish to purchase Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work SAFETY...

Page 2: ...Contact the nearest Authorized Warranty Service Center that provides on site service calls for service call arrangement If the purchaser does not receive satisfactory results from the Authorized Warr...

Page 3: ...DRILL INTO WELD OR MAKE ANY MODIFICATIONS TO THE TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPERATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTI TUTIONS TO ALTER THE FAC...

Page 4: ...BY AUTHORIZED SERVICE CEN TER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES MAKE CERTAIN THAT THE ELECTRICAL CIRCUIT TO WHICH THE COMPRESSOR IS CONNECTED PROVIDES PROPER ELECTRI CA...

Page 5: ...ed to correct such problems This should be done regardless of any visible signs of damage to the shipping container If this product was shipped directly to you report any damages to carrier and arrang...

Page 6: ...heels are properly installed NOTE The side of the wheel that the hub protrudes out past the wheel edge should be bolted to the compressor leg THE WHEELS AND HANDLE DO NOT PROVIDE ADEQUATE CLEARANCE ST...

Page 7: ...compressor life Use air compressor oil only Compressorsareshippedwithoutoil Asmallamount ofoilmaybepresentinthepumpuponreceiptofthe aircompressor Thisisduetoplanttestinganddoes notmeanthatthepumpcont...

Page 8: ...n cock The air compressor can now be stored Piping Plastic or PVC pipe is not designed for use with compressed air Regardless of its indicated pressure rating plastic pipe can burst from air pressure...

Page 9: ...placement Keep the air filter clean at all times Do not operate the compressor with the air filter re moved A dirty air filter will not allow the compressor to operate at full capacity Before you use...

Page 10: ...skets 7 Install the cylinder head Snug mounting screws and studs tight then torque to 25 to 30 foot pounds starting at the center and working toward the outside 8 Reconnect the pressure release and ou...

Page 11: ...vice Center to check remove or replace switch Tighten fittings where air can be heard escaping Check fittings with soapy wa ter solution DO NOT OVER TIGHTEN A defective check valve results in a consta...

Page 12: ...o 25 30 ft lbs using new gasket and torque screws Let the motor cool off and reset switch by pressing the red button located on the end of the motor If the overload still trips check for defective cap...