background image

Page 4

SB-2-542-E

InStallatIon

Important: to ensure that this 

equipment reaches you in first 

class condition, protective coat-

ings have been used. flush the 

equipment through with a suit-

able solvent before use.

1.   Attach air hose to connector (13). 

Recommended hose size 8 mm bore. 

The hose must be conductive and 

electrical bond from the spraygun to 

earth should be checked with an 

ohmeter. A resistance of less than 

10

6

 Ohms is recommended.

2.   

Attach fluid supply hose to Fluid 

Inlet (15). 

opEratIon

1.   

Mix coating material to manufac-

turers instructions

2.   

Turn needle adjusting screw (7) 

clockwise to prevent movement. 

3.   

Turn spreader valve (5) counter-

clockwise to fully open.

4.   Adjust inlet air pressure (For recom-

mended figures see Specifications) 

at the gun inlet with the gun trig-

gered. (pressure gauge attachment 

shown under Accessories is recom-

mended for this).

5.   Turn needle adjusting screw counter 

clockwise until first thread shows.

6.   Test spray. If the finish is too dry 

reduce airflow by reducing air inlet 

pressure or by the Airflow Valve (14). 

Screw the Adjusting Knob (14) in to 

reduce pressure. 

7.   If finish is too wet reduce fluid flow 

by turning needle screw (7) clock-

wise or reducing the fluid pressure. 

If atomization is too coarse, increase 

inlet air pressure. If too fine reduce 

inlet pressure.

8.   The pattern size can be reduced by 

turning adjusting valve (5) clock-

wise.

9.   Hold gun perpendicular to surface 

being sprayed. Arcing or tilting may 

result in uneven coating.

10.   The recommended spray distance is 

150-200 mm (6"-8").

11.  

Spray edges first. Overlap each 

stroke a minimum of 50%. Move gun 

at a constant speed.

12.   Always turn off air and fluid supply 

and relieve pressure when gun is 

not in use.

prEVEntatIVE maIntEnancE

1.   Turn off air and coating supply and 

relieve  pressure in the supply lines, 

or if using QD system, disconnect 

from airline and fluid line.

2.   Remove air cap (1) and clean. If any 

of the holes in the cap are blocked 

with coating material use a toothpick 

to clean. Never use metal wire which 

could damage the cap and produce 

distorted spray patterns

3.   Ensure the tip of the nozzle (2) is 

clean and free from damage. Build 

up of dried paint can distort the 

spray pattern.

4.   Lubrication – stud/screw (6), needle 

(9) and air valve (11) should be oiled 

each day.

rEplacEmEnt of partS

nozzle (2) and needle (9) – Remove parts 

in the following order: 7, 8, 9, 1 and 2. 

Replace any worn or damaged parts and 

re-assemble in reverse order. 

Recommended tightening torque for 

nozzle (2) 9.5-12 Nm (80-100 lbf in). 

packing – Remove parts  7, 8, 9. Unscrew 

cartridge (4). Fit new cartridge finger 

tight. Re-assemble parts 9, 8, and 7 and 

tighten cartridge (4) with spanner suffi-

cient to seal but to allow free movement 

of needle. Lubricate with gun oil.

air Valve Seal Kit (16) – (Refer to photos 

1 to 28 and fig 2) 

Spreader valve (5) – caution: always 

ensure that the valve is in the fully open 

position by turning screw fully counter-

clockwise before fitting to body.

SpEcIfIcatIon

air supply connection: 

Universal 1/4" BSP and NPS

fluid supply connection: 

Universal 3/8" BSP and NPS

maximum static air inlet pressure: 

P

1

 = 12 bar (175 psi)

maximum static fluid inlet pressure: 

P

2

 = 15 bar (218 psi)

nominal gun air inlet pressure  

with gun triggered: 2 bar (29 psi)  

510, 513 & 522 Trans-Tech Air Cap

maximum Service temperature: 40°C

Gun Weight: 412 g

matErIalS of conStructIon

Gun body: Anodized Aluminum

nozzle: Stainless Steel

needle: Stainless Steel

fluid Inlet / fluid passages: 

Stainless Steel / PTFE

trigger: Nickel Plated Steel

aIr cap SpEcIfIcatIonS

Sp-100-510-K (pressure/Siphon) 

10.0 CFM @ 29 psi inlet 

Fan Pattern Max: 10.6"

Sp-100-513-K (pressure/Siphon) 

14.1 CFM @ 29 psi inlet 

Fan Pattern Max: 13.8"

Sp-100-522-K (pressure only) 

14.5 CFM @ 29 psi inlet 

Fan Pattern Max: 13.8"

Summary of Contents for Compact TRANS-TECH

Page 1: ...SB 2 542 E Replaces SB 2 542 D Operation Manual Trans Tech PRESSURE Feed SIPHON FEED Spraygun English Pages 2 9 Manual de Operaci n COMPACT Pistola Pulverizadora POR PRESI N POR sif n TRANS TECH Espa...

Page 2: ...for use with Halogenated Hydrocarbons Static Electricity can be generated by fluid and or air passing through hoses by the spraying process and by cleaning non conductive parts with cloths To prevent...

Page 3: ...housing seal SP 612 K 1 11 Spindle 1 12 Trigger SP 617 K 1 13 Connector SP 611 K 1 14 Plug JGA 132 1 15 Fluid Inlet Connector and seal SP 636 K 1 17 Retaining Ring and Seals SPK 102 K 1 18 Clip Seal...

Page 4: ...ly and relieve pressure in the supply lines or if using QD system disconnect from airline and fluid line 2 Remove air cap 1 and clean If any of the holes in the cap are blocked with coating material u...

Page 5: ...g Service Tool SPN 7 engage groove behind the Valve Seat 6 Remove Valve Seat 7 Push out the Front Airvalve Seal with a finger 8 Turn the Gun upside down and let the Seal fall out 9 Fit New Front Seal...

Page 6: ...ment 14 Fit new Seal to Service Tool 15 Fit Seal to Housing 10 16 Replace Valve 11 17 Replace Valve Spring and screw in Housing 10 18 Tighten Housing 19 Fit Needle 9 20 Fit Spring 8 and Knob 7 21 Adju...

Page 7: ...loose fluid needle packing nut Lubricate or tighten Unable to get round spray Spreader adjustment screw not seating properly Clean or replace Air cap retaining ring loose Tighten Will not spray No air...

Page 8: ...el Too much material coarsely atomized Increase air pressure or decrease fluid pressure Air pressure too low Increase air pressure or reduce fluid pressure Improper thinner being used Follow paint man...

Page 9: ...ype 1 Qt pressure feed cups 3 8 NPS F cam lock lid Requires KK 4980 air regu lator kit TLC 576 Aluminum Cup Teflon Lined TSC 591Stainless Steel Cup KB 555 Aluminum KB 545 SS S S 2 qt Pressure Feed Cup...

Page 10: ...y como se suministra NO es adecuado para su uso con Hidrocarburos Halogenados La Electricidad Est tica puede ser generada por el paso de fluido y o aire por los manguitos por el proceso de pulverizaci...

Page 11: ...de la v lvula de aire SP 612 K 1 junta 11 V stago 1 12 Gatillo SP 617 K 1 13 Conector SP 611 K 1 14 Tap n JGA 132 1 15 Entrada de fluido Conector y junta SP 636 K 1 17 Ret n y juntas SPK 102 K 1 18 K...

Page 12: ...miento Preventivo 1 Cierre el suministro de aire y recu brimiento y alivie la presi n en los manguitos o si utiliza el sistema QD descon ctelo del manguito de aire y de fluido 2 Retire el casquillo de...

Page 13: ...o de la v lvula 6 Retire el asiento de la v lvula 7 Haga salir la junta delantera de la v lvula de aire empu jando con el dedo 8 Ponga la pistola boca abajo y deje que se caiga la junta 9 Instale una...

Page 14: ...nta de manten imiento 15 Coloque la junta en el aloja miento 10 16 Vuelva a colocar el husillo 11 17 Vuelva a colocar el muelle de la v lvula y el tornillo en el alojamiento 10 18 Apriete el alojamien...

Page 15: ...fluido en el tanque Abra el tornillo de ajuste de la aguja de fluido Diluya el material o cambie a alimentaci n por presi n Sobrepulverizaci n excesiva Demasiada presi n de aire de atomizaci n La pist...

Page 16: ...presi n del fluido Aumente la presi n de aire o reduzca la presi n del fluido Siga las instrucciones de mezclado del fabricante de la pintura Siga las instrucciones de mezclado del fabricante de la pi...

Page 17: ...4 de pulg NPS F Dispositivo de desconexi n r pida aprobado para pistolas HVLP aire Tipo de bola y anillo de alto flujo Cubetas alimentadas por presi n de 1 cuarto de gal n 3 8 de pulg NPS F tapa con c...

Page 18: ...Page 18 SB 2 542 E NOTES...

Page 19: ...P gina 19 SB 2 542 E NOTAS...

Page 20: ...rnationale Blvd Glendale Heights IL 60139 630 237 5000 Toll Free Customer Service and Technical Support 800 992 4657 Toll Free Fax 888 246 5732 DeVilbiss Sales and Service www devilbiss com WARRANTY T...

Reviews: