High-performance automatic gun
AGMD
1-1-AGMD-514&515-E-002-1
15
5.3 Removing the high-performance automatic spray gun AGMD
Note!
Only trained personnel are permitted to install and remove parts of the high-
performance automatic spray gun AGMD.
The work should be performed on a clean horizontal work surface.
For the assembly and disassembly of the high-performance automatic spray gun
AGMD, follow the respective parts list and the exploded drawing.
After the removal and replacement of the high-performance automatic spray gun
AGMD on the adaptor, the spraying process can continue, and the defective high-
performance automatic spray gun AGMD can be serviced at a suitable location.
The item indicated in parentheses corresponds to the individual parts from Chapter
AGMD-514 (conventional atomisation)
1. Screw on retaining ring (item 1) and
remove air cap (item 2).
2. Loosen and remove the nozzle (item 3)
with socket wrench, size ½“.
3. Remove the air distributing ring (item 5)
and both gaskets (item 4).