15. Malfunction code
Field Service Ver. 1.0 Apr. 2005
136
ineo 161
ineo 210
T
roubleshooting
15.3.2
C0044: ADF Cooling Fan Failure
(When the optional Duplexing Document Feeder DF-605 is mounted)
A. Detection Timing
B. Action
Trouble Code
Description
C0044
• The ADF Fan Motor Lock signal remains set to H for a set period of time while
the EDH Fan Motor is turning.
Relevant Electrical Components
Cooling Fan Motor (M3-ADF)
Main Control Board (PBA-CONT)
Step
Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check the motor connectors for
paper connection, and correct as
necessary.
–
–
–
2
Check the fan for possible overload,
and correct as necessary.
–
–
–
3
M3-ADF operation check.
☞
PBA-CONT CN9CONT-2
(REM)
E-5 (DF-605)
4
Replace PBA-CONT.
–
–
–