Field Service Ver. 1.0 Apr. 2005
10. Service Mode
89
ineo 161
ineo 210
Adjustment / Setting
N. LOOP ADJUST (DUPLEX): ineo 210 only
O. LOOP ADJUST (BYPASS)
P.
FLS PAPER SIZE
Q. CCD APS SIZE
R. GDI TIMEOUT
Purpose/Use
To adjust the length of the loop formed in the paper before the Synchronizing Roller.
✽
When a skew feed, fold, or misfeed of paper occurs
✽
When variations in the amount of void on the leading edge occurs
Setting/
Procedure
✽
Refer to the option service manual (AD-504) for details.
Purpose/Use
To adjust the length of the loop formed in the paper before the Synchronizing Roller
when the Manual Bypass is used.
✽
When a skew feed, fold, or misfeed of paper occurs
✽
When variations in the amount of void on the leading edge occurs
Setting/
Procedure
Setting range: -3.9 to 3.9 mm (1 step: 0.6 mm)
Adjustment
Procedure
1. Call Service’s Choice of Service Mode to the screen.
2. Select “Loop Adjust (Bypass)” and press the [Yes] key.
3. Using [
▲
/
▼
] key, select the desired setting value.
4. Press the [Yes] key to validate the setting value selected in step 3.
Adjustment Instructions
• Try a different setting value until there are no variations in the amount of void on
the leading edge, and paper skew, fold, or misfeed.
Purpose/Use
To select the paper size for FLS.
✽
When the FLS paper size is changed
✽
At setup
Setting/
Procedure
• The default setting is “330
✽
210.”
330
✽
203
“330
✽
210”
330
✽
216
330
✽
220
337
✽
206
Purpose/Use
To set the automatic paper size detection function for CCD scan.
Setting/
Procedure
• The default setting is “PATTERN1.”
“PATTERN1”
PATTERN2
Purpose/Use
To specify the time for timeout when data from PC is interrupted during GDI printing.
Setting/
Procedure
• The default setting is “6.”
0 (5 sec.) 1 (10 sec.) 2 (20 sec.) 3 (30 sec.) 4 (40 sec.) 5 (50 sec.) “6 (60 sec.)”