FrameMaker Ver.5.5E(PC) DIS/REASSEMBLY, ADJUSTMENT FOR Di152/Di183
01.09.03
D-67
11. Put the Developing Assy and Cleaning Assy together.
10. Install the Db Gap Adjusting Jigs in a space
between the Sleeve Roller and Doctor Blade.
4022D021AB
12. Press the Doctor Blade tightly up against the Db
Gap Adjusting Jigs and, keeping that position,
tighten the screws in the order of
➀
at the front,
➁
at the center, and
➂
in the rear.
NOTE
• The Doctor Blade mounting screws have been
coated with lock paint and the job must be com-
pleted within 30 min. It the job extends more than
that time, change the screws for new ones.
4022D022AB
➀
➁
➂