background image

Keypad - KEYZB-110 

 Technical manual

 

 

 

Develco Products A/S

 

Tangen 6 

http://develcoproducts.com 

 

DK-8200 Aarhus N 

[email protected] 

 

11

 

4.2.1.3

 

Commands  

The IAS ACE cluster has 3 commands as client server. 
 

Id# 

Name 

Payload  

0x00 

Arm 
 

Bits 

Varies 

Data 

type 

Enum8 

string 

Uint8 

Field 

name 

Arm Mode 

Arm/Disarm code 

Zone ID 

0x02 

Emergency 

No payload, 

Commands indicate an emergency situation 

0x07 

GetPanelStatus 

No payload,  

 

Commands This command is used by ACE clients to request 

an update to the status of the ACE 
server (i.e., the IAS CIE). 

 
Keypad button functionality 

Symbol 

Function  

 

Arm All Zones 

 

Disarm 

 

Arm Day/Home Zones Only 

 

Arm Night/Sleep Zones Only 

 

Emergency 

 Press button for 3 sec 

 

Delete last symbol input from keypress 

0

 

to “9”

 

Input to Arm/Disarm code 

 

 

 

Summary of Contents for KEYZB-110

Page 1: ...Keypad KEYZB 110 Technical manual Revised 06 05 2020 ...

Page 2: ...1 Common clusters for each end point 8 4 1 1 Basic Cluster id 0x0000 8 4 1 1 1 Attribute 8 4 1 2 Identify Cluster id 0x0003 8 4 1 2 1 Attribute 8 4 1 2 2 Commands 8 4 2 IAS ACE Device EP 0x2C 9 4 2 1 IAS Zone Cluster id 0x0500 9 4 2 1 1 Attribute 9 4 2 1 2 Commands 10 4 2 1 3 Commands 11 4 2 2 Power Configuration Cluster id 0x0001 12 4 2 2 1 Attribute 12 4 2 3 Poll Control Cluster id 0x0020 12 4 2...

Page 3: ...0x000A 15 4 2 5 1 Attribute 15 5 MMI user guide 16 5 1 Panel description 16 5 2 Menu button 17 5 2 1 EZ mode Initiator 18 5 2 2 EZ mode Target 18 5 2 3 Factory reset 18 5 3 Action on Power On 18 6 General network behaviour 19 6 1 Installation 19 6 2 Normal Keep alive 19 6 2 1 Network lost 19 6 3 Low battery 20 7 Specifications 21 8 Contact Information 22 ...

Page 4: ...Products assumes no responsibility for any errors which may appear in this manual Furthermore Develco Products reserves the right to alter the hardware software and or specifications detailed herein at any time without notice and Develco Products does not make any commitment to update the information contained herein All the trademarks listed herein are owned by their respective owners RoHS ...

Page 5: ...ary notes Develco Products A S reserves the right to make changes to any product to improve reliability without further notice Develco Products A S does not assume any liability arising out of the application or use of any product or circuit described herein neither does it convey any license under patent rights or the rights of third parties ...

Page 6: ...ening of the unit which makes it suitable for alarm systems Also the Keypad includes a programmable buzzer for indication of entry exit alarms or any other indication needed in your solution Red Green and Yellow LEDs are available for indications of alarms etc The Keypad can be delivered in white for indoor use or in black for outdoor use The device has 16 buttons that you can design to fit your s...

Page 7: ...ile Id 0x0104 Home Automation Application device Id 0x0401 IAS Ancillary Control Equipment 3 3 Develco Utility Application profile Id 0xC0C9 Develco Products private profile Application device Id 0x0001 Manufactor code for Develco Products is 0x1015 Private profile for internal Develco Products use only Reference documents 053474r18ZB_CSG ZigBee Specification pdf 075123r03ZB_AFG ZigBee_Cluster_Lib...

Page 8: ...levant to a Develco device are all in set 0x000 4 1 1 1 Attribute Id Name Type Range Man Opt Relevance and ref 0x0 ZCLVersion Uint8 Type range M 0x4 ManufacturerName String 0 32 byte O 4 1 1 1 1 0x5 ModelIdentifier String 0 32 byte O 4 1 1 1 2 0x6 DateCode String 0 32 byte O 0x7 PowerSource 8 bit enum Type range M 4 1 1 1 1 ManufacturerName Develco Products A S 4 1 1 1 2 ModelIdentifier KEYZB 110 ...

Page 9: ...e 16 bit Enumeration M Hard coded to Keypad 0x0002 Zone Status Uint16 M The following bits are supported Bit2 Tamper Bit3 Battery Bit4 Supervision reports Bit5 Restore reports 0x0010 IAS CIE Address Valid 64 bit IEEE address M 0x0011 ZoneID Uint8 M 0x8000 Zone Status Interval Uint16 O Default 300 sec 4 2 1 1 1 Zone State The device will automatically start to scan the network for an IAS Zone clien...

Page 10: ...mands The IAS Zone cluster has 2 commands as server Id Name Payload Man Opt Relevance and ref 0x00 Zone Status Change Notification Uint16 bit mask M The status is report to the coordinator every 5 min 0x01 Zone Enroll Request Bits 16 16 M Data type 16 bit enum UINT16 Field name Zone type Manufacturer code Init sequence when the device has join the network it start to scan for an IAS zone client cl...

Page 11: ...Field name Arm Mode Arm Disarm code Zone ID 0x02 Emergency No payload Commands indicate an emergency situation 0x07 GetPanelStatus No payload Commands This command is used by ACE clients to request an update to the status of the ACE server i e the IAS CIE Keypad button functionality Symbol Function Arm All Zones Disarm Arm Day Home Zones Only Arm Night Sleep Zones Only Emergency Press button for 3...

Page 12: ...d device to the end device s parent This cluster can be used for instance by a configuration device to make an end device responsive for a certain period of time so that the device can be managed by the controller 4 2 3 1 Attribute Id Name Type Range Man Opt Relevance and ref 0x0000 Check inInterval Uint32 0x00 0xFF M Default value is 1 hour 0x0001 LongPoll Interval Uint32 M Default value is 7 5 s...

Page 13: ...ance and ref 0x0000 UpgradeServerID IEEE Address M 0x0001 FileOffset Uint32 Type range O 0x0002 CurrentFileVersion Uint32 Type range O 0x0003 CurrentZigBeeStackVersion Uint16 Type range O 0x0004 DownloadedFileVersion Uint32 Type range O 0x0005 DownloadedZigBeeStackVersion Uint16 Type range M 0x0006 ImageUpgradeStatus 8 bit enum 0x00 to 0xFF O 0x0007 Manufacturer ID Uint16 Type range O 0x0008 Image...

Page 14: ...Keypad KEYZB 110 Technical manual Develco Products A S Tangen 6 http develcoproducts com DK 8200 Aarhus N info develcoproducts com 14 Identifiers 4 2 4 3 OTA Upgrade Messages Diagram ...

Page 15: ...s 0 mins 0 sec on 1st January 2000 Refer to Z2 for ZigBee specification of the time cluster The device will use this clusters as a client provided that a suitable Time Server is available on the network most likely on the Gateway 4 2 5 1 Attribute Id Name type Range Man Opt Relevance and ref 0x0000 Time UTCTime Uint32 Type range M The module will periodically update its clock by synchronizing thro...

Page 16: ...Night Sleep Zones Only Emergency Press button for 3 sec Delete last symbol input from keypress 0 to 9 Input to Arm Disarm code LED 1 Arm All Zones RED LED solid on for 30 sec Arm Day Home Zones Only RED LED solid on for 30 sec Arm Night Sleep Zones Only RED LED solid on for 30 sec Exit delay Red LED flash slow along with beep In alarm Red LED flash fast LED 2 Network connection lost Yellow LED fla...

Page 17: ...he device The menu button is placed between the batteries and a thin pin eg a paper clip can be used to activate the button Pushing the button on a device provides the user with several possibilities Pushing the button for longer push hold for a few seconds and release allows the user to set the device into a desired mode A mode change happens at 5 second interval Below these modes are illustrated...

Page 18: ...inks twice every 1 sec until the devices has joined the network If the device was already on the network it will broadcast the PermitJoin messages It is the trust center policy that decides if the device is allowed to join the network When the device has joined the network identify mode is invoke and the device start to blink twice every 3 sec until identify mode is stopped or after the EZ mode ti...

Page 19: ...de 2 will be used after scan mode 1 has expired Scan mode 1 it will only be executed one time when the device is powered If the user invokes EZ mode it will start scanning the next 3 minutes In section 5 MMI it is explained how to put the device into a join or leave network mode Network settings are stored in NV memory are after a power cycle the device re join the same network If the device has t...

Page 20: ...15 minutes Scan mode 2 Scan current ch 3 times Scan remaining 15 channel 1 time Sleep mode MCU is in sleep mode Radio off 15 minutes Scan mode 2 Scan current channel 3 times Scan remaining 15 channel 1 time 6 3 Low battery The current battery voltage can be read from the power configuration cluster described in section 4 3 1 The attribute BatteryVoltage is measuring the battery voltage in units of...

Page 21: ...ormal usage Radio Sensitivity 100 dBm Output power 10 dBm Environment For indoor and outdoor use Operation temperature 0 to 50 C Function Presence Detection of person present within 5 10 cm Detection interval 500 ms 1s reaction RFID Mifare reader Reading distance 5 cm Keypad 0 9 6 function buttons Backlight On when unit active person present and light level low Communication Wireless protocol ZigB...

Page 22: ...ucts com DK 8200 Aarhus N info develcoproducts com 22 8 Contact Information Technical support Please contact Develco Products for support products develcoproducts com Sales Please contact Develco Products for information on prices availability and lead time info develcoproducts com ...

Reviews: