1. Specifications: 

‹

 

Operating Voltage: 12 Vdc 

‹

 

Current Draw: Average 15mA, Peak 100mA @ 12Vdc  

‹

 

Input:  request-to-exit, time out reed switch contact 

‹

 

Output: Dual relays, N.O./N.C./Com. Output (free voltage 
contact)       

‹

 

Relays Electric Current: 2A MAX @30Vdc 

0.4A @ 

120Vac  

‹

 

Relay Activation Time:  

„

 

Relay 1 time delay setting code

「*

30

」、

Relay 2 

setting code

「*

31

 

„

 

Strike Time: 1~99 seconds

adjustable

 

„

 

Strike mode: Access Timer or Latch 

‹

 

Memory Volume: 20+1 PIN codes   

„

 

Relay 1 is controlled by 

01~

20 user slots 

„

 

Relay 2 is controlled by 

21 user slots 

‹

 

Operating Temperature: -20~+70

 

‹

 

Ambient Humidity: 5~95% relative humidity non-condensing 

‹

 

Factory Master Code: 12345 

‹

 

Invalid PIN Lock-out: The system will shut down for 60 seconds while 30 codes of 
incorrectly Master Codes enrolled or PIN codes attempted

None beeper signal of 

keypad activations

‹

 

EPROM:  Non-volatile memory, System will retain all programs and codes after a total   
loss of power. 

‹

 

The indicator signal chart: 

LED signal 

Sound signal 

Green LED  

Power on, stand-by  

1 Beep 

Effective PIN codes

Any key pressed 

Red LED 

Relay 1 activated 

2 Beeps 

Entering 

Exiting from the Program mode

Yellow LED 

Relay 2 activated 

3 Beeps 

Data computing error 

  

Beeps 

Master Code reset to Factory 

12345

 

 

2. Operation Instruction: 

‹

  Enter Program Mode: 

1.  Compose twice the master code (4 digit format press

1234

」、

5 digit format press

12345

 2 beeps 

 you are now in the "programming mode". 

2.  After 60 seconds if you have not entered any codes or data, the system will 

automatically exit from the programming mode.  

‹

  Exiting from the program mode: 

1. Press

#

 to exit from the programming mode. 

2.  After 30 wrong codes attempts at the master code the lockout facility will operate. 

‹

  Add PIN codes  

Enter the Programming mode, Enter the slot position code 

「*

01~

20

????? Input 

5 digit 

or 4 digit

PIN codes

 (beep) enrolled 

Æ

repeat

 

Press 

#

 to exit from the programming mode, or program other operating. 

Note 1:

 The codes

0000

,

00000

,

1234

,

12345

or master code are not be 

used for PIN code. 

Note 2:

 Relay 2 is controlled by 

21 user slots 

‹

  To Delete a User Code

 

Copyright Gianni Industries, Inc. All Rights Reserved. 
P-MU-DG15  Ver. C  Publish:2008.11.12                                                             Page: 1/ 3 