Keypad - KEYZB-110
–
Technical manual
Develco Products A/S
Tangen 6
http://develcoproducts.com
DK-8200 Aarhus N
17
Low battery: Yellow LED will blink 2x every 60 second
Timeout since last input (5 sec): Yellow LED blink 3x
Wrong PIN code: Yellow LED blink 3x
LED 3
Disarm: Green LED solid on for 3 sec
Not ready to arm: Green LED solid on for 3 sec
Entry delay: Green LED flash along with beep
Sensor
Presence Light RFID tag reader
5.2
Menu button
How to get access to the menu button on the keypad:
Open the casing of the device by removing the screw at the bottom of the device. The menu button is placed
between the batteries and a thin pin (eg. a paper clip) can be used to activate the button.
Pushing the button on a device provides the user with several possibilities.
Pushing the button for longer (push, hold for a few seconds, and release) allows the user to set the device into a
desired mode. A mode change happens at 5 second interval. Below, these modes are illustrated in a state chart
Idle
EZ mode
Initiator
EZ mode
Target
Factory reset
Push + Hold button
untill led blinks once
Push + Hold button
untill led blinks
continously
Push + Hold button
untill led blinks
twice
Push + Hold button
untill led is off
When cycling through the menu modes, the state is indicated by a number of blinks on the LED. The device is
supporting the ZigBee standardized EZ- mode Commissioning.