![DEVA Broadcast DB7000 Maintenance And Operating Instructions Download Page 73](http://html.mh-extra.com/html/deva-broadcast/db7000/db7000_maintenance-and-operating-instructions_2488545073.webp)
- 73 -
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
Parameter Name
Type
Range
Default value [, Unit]
Description
Communication
Communication related submenu
General Setup
General communication settings
Ethernet
ENUM
Enable, Disable
Enable
Ethernet port (general)
SNMP
ENUM
Enable, Disable
Enable
SNMP protocol
Application
ENUM
Enable, Disable
Enable
Application proprietary protocol
HTTP
ENUM
Enable, Disable
Enable
HTTP protocol (WEB server)
FTP
ENUM
Enable, Disable
Enable
FTP protocol
ENUM
Enable, Disable
Enable
SMTP protocol (email)
SNTP
ENUM
Enable, Disable
Enable
SNTP protocol (Internet time)
Audio Stream
ENUM
Enable, Disable
Enable
Audio streaming
Syslog
ENUM
Enable, Disable
Enable
SYSLOG protocol
USB
ENUM
Enable, Disable
Enable
USB port
UPnP
ENUM
Enable, Disable
Enable
UPnP protocol
Ethernet
Ethernet related submenu
DHCP
ENUM
Enable, Disable
Enable
DHCP Client
IP
IP
192.168.1.2
IP address (static)
Network Mask
NETMASK
255.255.255.0
Network mask (static)
Gateway
IP
192.168.1.1
Gateway address (static)
Primary DNS
IP
192.168.1.1
Primary DNS IP address (static)
Secondary DNS
IP
192.168.1.1
Secondary DNS IP address (static)
SNMP
SNMP related submenu
Manager IP
IP
192.168.1.1
Manager IP address
Manager Port
PORT
1 … 65535, step 1
162
Manager port
Agent Port
PORT
1 … 65535, step 1
161
Agent port
Agent ID
INT
0 … 255, step 1
0
Agent ID for the device
Read Community
STR
DEVA7000
Read community password
Write Community
STR
DEVA7000
Write community password