APPENDIX 2: List of DB7000 settings
Parameter Name
Type
Range
Default value [, Unit]
Description
Tuner
Tuner related submenu
Frequency
INT
87.1 … 108.1, step 0.05
98.1, MHz
Currently set frequency
RF Input
ENUM
Antenna 1, Antenna 2
Antenna 1
Active RF antenna input
Attenuator Ant 1
ENUM
Auto, OFF, -10dB, -20dB, -30dB
Auto
Attenuator setting for antenna input 1
Attenuator Ant 2
ENUM
Auto, OFF, -10dB, -20dB, -30dB
Auto
Attenuator setting for antenna input 2
Frequency Step
ENUM
10, 20, 50, 100, 200
50, kHz
Step for frequency tuning
IF Bandwidth
ENUM
27, 36, 45, 53, 62, 71, 79, 88, 97, 105, 114, 123,
131, 140, 149, 157, Auto
Auto, kHz
IF filter bandwidth
Stereo Blend
ENUM
Auto, Off
Auto
Stereo blend level
High Cut
ENUM
Auto, Off
Auto
High cut level
High Blend
ENUM
Auto, Off
Auto
High blend level
Soft Mute
ENUM
Auto, Off
Auto
Soft mute level
Audio Cut
ENUM
5, 10, 15, Off
Off, kHz
Audio cut level
Deemphasis
ENUM
FLAT, 50, 75
50, µs
De-emphasis settings
RDS Mode
ENUM
RDS, RBDS
RDS
RDS decoder mode
PI Protection
ENUM
Enable, Disable
Disable
PI Protection Enable
PI
PI
PI Protection code
RF Loss Threshold
INT
0 … 110, step 1
40, dBµV
RF threshold level
RF Loss Timeout
TIMER
1 … 60, step 1
1, s
RF timeout
Average and Peak
Signal averaging related submenu
Attack Time
INT
0 … 500, step 10
50, ms
Attack time for signal measuring
Release Time
INT
50 … 1000, step 10
500, ms
Release time for signal measuring
Peak Hold
INT
500 … 5000, step 500
1500, ms
Peak hold time