![DEVA Broadcast DB7000 Maintenance And Operating Instructions Download Page 46](http://html.mh-extra.com/html/deva-broadcast/db7000/db7000_maintenance-and-operating-instructions_2488545046.webp)
65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: [email protected] ,Web: www.devabroadcast.com
- 46 -
Settings Menu screen structure
Settings menu title
– shows the path to the currently selected menu. Note that the parameter should be included in
the settings menu title.
For example:
Settings > Communication > Application - Port
is different
from
Settings > Communication > HTTP - Port
.
Navigation area
– selection of branches / parameters is made in this area. The selected item is highlighted. All
parameters are listed on the left side of the navigational area. All parameter values are displayed
on the right side against the parameter name. Since branches have no values associated, tree dots
are shown instead. This indicates that a transition to a sub-menu is available.
Front panel buttons usage:
OK
– Depending on the selected menu element can perform different actions:
•
Menu branch – transition to selected sub-menu will be made;
•
Menu parameter – when a value of a parameter is highlighted pressing OK will switch to
edit mode;
•
Menu complex parameter (such as Alarm) – the parameter editor screen will be shown.
Up
/
Down
– If edit mode is active, the value of the selected parameter will be changed. Otherwise,
are used for navigation through the menu;
Left
/
Right
– Change the selection when the parameter value is in edit mode;
SB4
– Return one level up or cancel edit mode.
There are several parameter types available in DB7000. The way of editing depends of the
parameter type. Every parameter type has its own editing rules.
Numerical parameter
(
INT
). Represents numerical value.
Example: The value
frequency
can be changed in the range of 87.10 to 108.10 MHz and step
of 10, 20, 50 or 100 kHz.
INT
mode, front panel buttons usage:
Up/Down - Change the value of the parameter with one step. The step value may vary depending
on the selected parameter. The value always stays in permitted parameter range;
OK -Accept the changed value and exit edit mode;
SB4 will discard the value and cancel edit mode.
Enumerated parameter
(
ENUM, TZONE
). Represent the selection of a value among set of
predefined enumerated values.
Example: The value
Attenuator
can be selected from “Auto”, “OFF”, “-10dB”, “-20dB” and
“-30dB”.
ENUM
mode, front panel buttons usage:
Up/Down – Cycle through the possible values;
OK - Accept the changed value and exit edit mode;
SB4 will discard the value and cancel edit mode.