User Manual DEV 1953
130
Copyright DEV Systemtechnik GmbH 2015-2017
The event and its status (pending or not) are still stated in the .errorTable and
in the Events Tab of the Web Interface where the event can be acknowledged
and deleted (if it is not pending anymore).
If the Sandar Prosan
PMP0
command (please refer to chapter 5.6.3.9) is issued,
Bit 1 of the .errorEnableMask is set to "
0
", thus disabling the reporting of all
power supply events via the
Q
,
AM
, or
AMA
commands (chapters 5.6.3.1 & 5.6.3.2)
With the
PMP1
command Bit 1 is set to "
1
".
By default all events are enabled, i.e. the .errorEnableMask is "
65535
".
5.9.4.4.3
.surveillance.numberOfErrors
OID:
.1.3.6.1.4.1.21035.41.3.3
.0
Syntax:
INTEGER32
Access:
read-only
Description:
The number of events.
Note:
This value is used to determine the maximum index of the following table:
5.9.4.4.4
.surveillance.errorTable
The .errorTable can contain a number of entries, each representing an event that is
classified by an error number. An error count per entry indicates the number of
occurrences of the specific event, and furthermore there it is specified per entry
when the last event of this type did occur, whether the event is still pending, and
whether the event was acknowledged or not. If .numberOfErrors (please refer to
chapter 5.9.4.4.3) is "
0
", the .errorTable is not available.
5.9.4.4.4.1
.surveillance.errorTable.errorEntry.errorIndex
OID:
.1.3.6.1.4.1.21035.41.3.4.1.1
.x
Syntax:
INTEGER32 (1..512)
Access:
not-accessible
Description:
A unique value for each table entry ranging between "
1
" and the
number of entries (defined by .numberOfErrors, chapter 5.9.4.4.3).
5.9.4.4.4.2
.surveillance.errorTable.errorEntry.errorNr
OID:
.1.3.6.1.4.1.21035.41.3.4.1.2
.x
Syntax:
INTEGER32
Access:
read-only
Description:
The error code (event identification) number.
Example:
"
4865
" (for a "Power Supply 1" event, please refer to chapter 6.1)
5.9.4.4.4.3
.surveillance.errorTable.errorEntry.errorCount
OID:
.1.3.6.1.4.1.21035.41.3.4.1.3
.x
Syntax:
INTEGER32
Access:
read-only
Description:
The number of occurrences of the event.