DEUTSCHMANN AUTOMATION V3470E Short Instruction Download Page 20

Summary of Contents for V3470E

Page 1: ...Starterkit ROTARNOCK mit PROFIBUS Artikel Nr V3470E Deutschmann Automation GmbH Co KG Carl Zeiss Str 8 D 65520 Bad Camberg 49 0 6434 9433 0 49 0 6434 9433 40 eMail info deutschmann de Internet http w...

Page 2: ...mbH Co KG 1 Introduction 4 2 Generating an AWF file automatically through WINLOC32 5 3 Operation of the data component generator 10 4 Operation of the data component simulator 12 5 Appendix 17 5 1 Har...

Page 3: ...Deutschmann Automation GmbH Co KG 3 Starterkit ROTARNOCK with PROFIBUS V 1 2 3 12 13...

Page 4: ...amme Deutschmann LOCON_ROTARNOCK WINLOC32 DEUTSCH Data component generator DBGenerator on the Support CD under Software Tools NEW DB Generator SetupS7DBGenerator exe The menu item can be found under P...

Page 5: ...it ROTARNOCK with PROFIBUS V 1 2 3 12 13 2 Generating an AWF file automatically through WINLOC32 Starting WINLOC32 For the further operation of WINLOC32 the menue Help is available The communication i...

Page 6: ...US V 1 2 6 Deutschmann Automation GmbH Co KG Generating an AWF file automatically through WINLOC32 Supply the device with voltage A window with the device s switch on message opens Read out the device...

Page 7: ...n Automation GmbH Co KG 7 Starterkit ROTARNOCK with PROFIBUS V 1 2 3 12 13 The graphic window displays an empty data record after the upload Now the cam values can be entered Depending on the device s...

Page 8: ...hrough WINLOC32 After entering the cams the data should be saved by File Save as Now the values that have been entered into WINLOC32 have to be transferred to the software S7DBGenerator exe This is ma...

Page 9: ...arterkit ROTARNOCK with PROFIBUS V 1 2 3 12 13 The following window opens searching for the drive path of the S7DBGenerator exe please use the Browser symbol for it The other input fields are not impo...

Page 10: ...the English flag For further operation of the DBGenerator the Help menue is available The software S7DBGenerator exe received all cam values The line angle angle cams should now contain the value 6 n...

Page 11: ...ann Automation GmbH Co KG 11 Starterkit ROTARNOCK with PROFIBUS V 1 2 3 12 13 In order to generate the data component click on File and Create DC Allocate a file name and save Angle angle cams 6 Angle...

Page 12: ...th PROFIBUS V 1 2 12 Deutschmann Automation GmbH Co KG Operation of the data component simulator 4 Operation of the data component simulator Start DatenbausteinSimulator exe Under Optionen Einstellung...

Page 13: ...Adjust the COM port for the PROFIBUS UART Dongle Enter the PROFIBUS Slave ID 126 is default on delivery current ID is passed out with 126 with the switch on message Select the GSD file R100 gsd under...

Page 14: ...ata component simulator There is a second window in the background After setting the right COM port it should look as followed Under Datei Oeffnen Select the generated AWL file with a click of the lef...

Page 15: ...oment you can see the current position and the address index should be running continuously Output 1 should now be set from 0 100 h0 h64 Besides the output status should change when the shaft is turne...

Page 16: ...onent simulator This method makes the testing of a data component rather simple It can now be imported into the S7 as decribed in the instruction manual V3526E L100 200 R80 100 with Fieldbus connec ti...

Page 17: ...utomation GmbH Co KG 17 Starterkit ROTARNOCK with PROFIBUS V 1 2 3 12 13 5 Appendix 5 1 Hardware connection A Cam control V3406 B PROFIBUS Dongle V2766 C Power supply V2757 D RS232 cable V2771 E Cable...

Page 18: ...If you return a unit to us we require as comprehensive a description of the error as possible We require the following information in particular What error number was displayed How is the unit externa...

Page 19: ......

Page 20: ......

Page 21: ...Servicing Deutschmann Automation GmbH Co KG 21 Starterkit ROTARNOCK with PROFIBUS V 1 2 3 12 13...

Reviews: