Implemented protocols in UNIGATE® CM
Data structure
Data mapping on the fielbus:
Example:
01 81 11 22 33 44 55 66 77 88 00 00 00
01 81 A1 A2 A3 A4 A5 A6 A7 A8 00 00 00 ...
A CAN message with COB-ID 181 and the data content "11 ... 88" in the first frame and "A1 ...
A8" in the second frame has been sent to the fieldbus.
Example for sending a message from fieldbus to CAN:
COB-ID should be 182, data content „0x01 … 0x04“
SPS Out (in Hex): 01 82 01 02 03 04
No further configuration like trigger bytes or fieldbus length byte are possible.
There is no diagnostic output for the fieldbus status on the CAN side as well as on the fieldbus
side.
14.3.3 Universal (L2 11Bit)
Data structure