background image

22

 

 

Table 11: Liste de pièces - Avec moteur PSC 

Item

Numéro

Description

Commentaires

1

B03775

ASS ÉCHANGEUR CHÂLEUR                   

Échangeur seulement

2

B03761

ASSEMBLAGE PLANCHER

3

B03746

CACHE FIL INTÉRIEUR

4

B03758

ASSEMBLAGE SÉPARATEUR BAS

Comprend panneau, 3 bandes et support à filtre

5

B03745

DÉFLECTEUR LATÉRAL                      

6

B03754-02

ASSEMBLAGE PANNEAU CÔTÉ GAUCHE

Comprend panneau, isolation, déflecteur et support à filtre

7

B03755-02

ISOLATION PANNEAU DE CÔTÉ  GAUCHE             

8

B03335-03

KIT ÉLECTRIQUE BVSO INTÉRIEUR

9

B03741-02

SUPPORT FILTRE ANGLE GAUCHE              

10

B03740

SUPPORT FILTRE CÔTÉ  GAUCHE                     

11

B03742

SUPPORT À FILTRE ARRIÈRE

12

Z04F014

FILTRE PAPIER 20 X 24 X 1

13

B03718-01

ASS PIÈGE À SON DE REMPLACEMENT

Comprend les 2 sections

14

B03756

ASS PORTE VENTILATEUR

Comprend porte, poigné et étiquettes

15

Z99F050

POIGNÉ ENCASTRÉE NOIR                    

16

B03764

ASS PORTE DE FILTRE ARRIÈRE             

17

F07O001

ÉCROU HEXAGONAL À BRIDE 3/8-16NC LAITON 

18

B01747

BRIDE D'ÉVACUATION 6" DIA.                        

19

B00205

GARNITURE, COUVERCLE DE TUYAU À FUMÉE   

20

B03757

ASS PANNEAU HAUT ARRIÈRE                

Comprend panneau et étiquette

21

J06L002

SCELLANT 1/8" DIA X 25'

22

B03751

PROTECTEUR SORTIE À FUMÉE

23

B03734

DIVISEUR HAUT                           

24

B03741-01

SUPPORT FILTRE ANGLE DROIT

25

B03754-01

ASSEMBLAGE PANNEAU CÔTÉ DROIT

Comprend panneau, isolation, déflecteur et support à filtre

26

B03755-01

ISOLATION PANNEAU CÔTÉ  DROIT

27

B03739

SUPPORT FILTRE CÔTÉ  DROIT

28

B03735

ESPACEUR DE BOITE ÉLECTRIQUE            

29

B03736

BOITE ÉLECTRIQUE                        

30

R02R009

CONTRÔLE HAUTE LIMITE L175-20F, .007 po.

31

B03743

COUVERCLE BOITE ÉLECTRIQUE              

Panneau seulement

32

B03118-01

KIT ÉLECTRIQUE BVSO EXTÉRIEUR

33

F06F015

RONDELLE ZINC 1 7/16"

34

Z99F061

OEIL DE REGARD POUR ÉCHANGEUR           

35

Z06G001

DISPOSITIF D'ARRÊT BVSO-225

36

B03675

GARNITURE SORTIE À FUMÉE

37

B03765

ASS BRIDE DE NETTOYAGE                  

Comprend item #36

38

B03762

ASS. COUVERCLE DE PROTECTION            

Comprend couvercle et étiquette 

39

F07F011

ÉCROU HEXAGONAL 3/8-16NC ZINC           

40

B03567-01

DÉFLECTEUR

Comprend un seul déflecteur

41

B03747

CACHE FIL BRÛLEUR                       

42

B03748

CACHE FIL

43

L04I010

CONNECTEUR PRESSION

44

B03759

ASS PANNEAU AVANT                       

Comprend panneau et isolation

45

B03760

ISOLATION PANNEAU AVANT                 

46

B03720-05

VENTILATEUR 120-10T DD 0,5PP

Comprend bâti, aube et étiquette

47

B03787-01

ASS VENTILATEUR DE REMPLACEMENT         

Comprend ventilateur, moteur et condensateur

48

B01756

SUPPORT DE VENTILATEUR                  

49

B01889

ASS SUPPORT DE MOTEUR                   

Comprend pattes, bande et attaches

50

L06K004

MOTEUR 1 HP, 4 VIT. DD

51

B01664-01

KIT ÉLECTRIQUE

52

B01024

SUPPORT DE CONDENSATEUR                 

53

L01I003

CONDENSATEUR 10 MF

54

L07F003

COMMUT, BASC. SPST

55

B03555

PROTECTEUR DE THERMO DISK

56

B03465

KIT ÉLECTRIQUE CARTE

57A R99G004

CARTE ÉLECTRONIQUE 1158

57B R99G002

CARTE ÉLECTRONIQUE ST9103

58

L01F009

TRANSFORMATEUR 120-24 Volts, 40VA

59

L01G009

FUSIBLE POUR CARTE DE CONTRÔLE - 3 AMPS

TERMINAL D'ÉVACUATION 5"

Pour combustion scellée

TUYAU D'ÉVACUATION FLEXIBLE ISOLÉ 8 PIEDS

Pour combustion scellée (B02551-07)

TUYAU D'ÉVACUATION FLEXIBLE ISOLÉ 10 PIEDS
TUYAU D'ÉVACUATION FLEXIBLE ISOLÉ 15 PIEDS

TUYAU D'ÉVACUATION FLEXIBLE ISOLÉ 20 PIEDS

Pour combustion scellée (B02551-08)

BRÛLEUR BECKETT NX (GICLEUR 0.75-60B)

BRÛLEUR RIELLO 40-F5 (GICLEUR 0.75-70A)

BRÛLEUR RIELLO 40-BF5 (GICLEUR 0.75-70A)

Pour combustion scellée

IFV-520

IFV-5-20

KLAFV0401DET

IFV-510
IFV-515

IFV-5-8

KLAFV0301DET

ACCESSOIRES

VTK-65

VTK-3

KLAVT0201DET

N01F056

KLABR0601RLO

N01J053

KLABR0301BEC

N01F053

KLABR0501RLO

 

B50095B 

Summary of Contents for OLR154F20A

Page 1: ...RMATION IN THIS MANUAL FOR THE INSTALLATION SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE At...

Page 2: ...ly air Temperature Rise Test 10 3 3 8 Limit Control Check 10 3 3 9 Restart after burner failure 10 4 MAINTENANCE 10 4 1 CLEANING THE HEAT EXCHANGER 10 4 2 CLEANING THE BLOCKED VENT SHUT OFF DEVICE BVS...

Page 3: ...formation such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform...

Page 4: ...re the ambient and return air temperatures are above 15 C 60 F In addition the furnace should be installed as closely as possible to the vent so that the connections are direct and kept to a minimum T...

Page 5: ...ired for Riello burners Refer to the burner control instruction manual and markings for proper adjustment of the post purge delay 2 5 VENTING WARNING Poisonous carbon monoxide gas hazard Never install...

Page 6: ...adequate supply of combustion air It is common practice to assume that older homes have sufficient infiltration to accommodate the combustion air requirement for the furnace However home improvements...

Page 7: ...ated the return air must be sealed and also be directed to the space other than where the furnace is located 2 9 1 Air filter A properly sized air filter must be installed on the return air side of th...

Page 8: ...heating or air conditioning mode This signal can be used to activate an electronic air cleaner that is not equipped with an air flow switch If the cleaner is equipped with an air flow switch the S te...

Page 9: ...of the oil piping and pump Slowly close and tighten the bleed screw Once closed the flame will light up 3 3 2 Pressure adjustment The oil pressure must be adjusted according to the Technical Specifica...

Page 10: ...burner should restart after a few minutes The time required for the restart also depends on the adjustment of the blower OFF delay 3 3 9 Restart after burner failure 1 Set the thermostat lower than r...

Page 11: ...uction inside the heat transfer tube 7 Re mount lock and fasten the control box with the 2 screws removed in step 4 8 Re attach the assembly cover with the screws removed in step 2 9 Re establish powe...

Page 12: ...vice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Amb...

Page 13: ...n 87 5 86 2 87 5 86 2 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse size Amps Control transformer VA External control power available Heating VA Cooling VA Heatin...

Page 14: ...Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time A 1 OFF 2 OFF 0 90 13 45 sec 44 30 sec 38 3 min B 1 ON 2 OFF 1 10 13 30 sec 44 30 sec 38 3 min C 1 OFF 2 ON 1 10 13 30 sec 50 30 sec 38...

Page 15: ...WITH AIR FILTER Table 10 Minimum clearances from combustible material LOCATION APPLICATION CLEARANCES combustible materials RECOMMANDED ACCESS FOR SERVICE FURNACE 2 54 cm 1 0 6 m 24 SUPPLY PLENUM WIT...

Page 16: ...16 Figure 7 Furnace Dimensions...

Page 17: ...17 Figure 8 Wiring Diagram 4 Speed Motor PSC...

Page 18: ...18 Figure 9 Wiring Diagram Variable Speed Motor ECM...

Page 19: ...19 Figure 10 Parts List With 4 Speed motor PSC B50095B...

Page 20: ...TERIOR 33 F06F015 ZINC WASHER 1 7 16 34 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 35 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 36 B03675 GASKET SMOKE OUTLET 37 B03765 CLEAN OUT ASSEMBLY Item 36 included 38...

Page 21: ...21 Figure 11 Parts List With variable speed motor ECM B50096C...

Page 22: ...ELECTRICAL BOX COVER Panel only 32 B03118 01 ELECTRICAL KIT BVSO EXTERIOR 33 F06F015 ZINC WASHER 1 7 16 34 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 35 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 36 B03675 G...

Page 23: ...NICIEN UTILISER LES RENSEIGNEMENTS DANS CE MANUEL POUR L INSTALLATION ENTRETIEN DE L APPAREIL ET GARDER LE DOCUMENT PR S DE L UNIT POUR R F RENCES ULT RIEURES PROPRI TAIRE S V P GARDER CE MANUEL PR S...

Page 24: ...rture de ventilation dans la porte du placard 4 Figure 2 Branchement du thermostat Chauffage et climatisation Unit avec moteur 4 vitesses 5 Figure 3 Branchement du thermostat Chauffage et Climatisatio...

Page 25: ...onduit comment le changer une fois par ann e iv Le filtre air comment le changer v rifier mensuellement et nettoyer ou changer si n cessaire g Avant d appeler pour le service prendre en note les rense...

Page 26: ...s doit tre utilis e 2 1 EMPLACEMENT MISE EN GARDE Risque d incendie ou d explosion L appareil doit tre install au niveau Ne jamais installer avec une inclinaison vers l avant Ne pas ranger ou utiliser...

Page 27: ...ils d origine de l appareil de chauffage central utilisez seulement du fil de cuivre r sistant la m me temp rature que les fils d origine 2 3 INSTALLATION DU THERMOSTAT L installation d un thermostat...

Page 28: ...ajustement 2 5 VACUATION MISE EN GARDE Risque d empoisonnement par monoxyde de carbone Lire et suivre toutes les instructions contenues dans cette section Ne jamais installer un volet manuel sur le tu...

Page 29: ...usqu la fin du cycle de refroidissement Si le fonctionnement n est pas conforme APPELER UN TECHNICIEN QUALIFI 2 7 APPROVISIONNEMENT EN AIR DE COMBUSTION ET VENTILATION MISE EN GARDE Risque d empoisonn...

Page 30: ...oir avec une pompe appropri e une l vation de 2 4 m 8 et plus requi re une pompe deux stages et une l vation de plus de 4 9 m 16 une pompe auxiliaire Suivre les directives d installation de la pompe p...

Page 31: ...fonction de la puissance de chauffage et de climatisation Les d lais de d part et d arr t du ventilateur en mode chauffage doivent aussi tre ajust s en positionnant les interrupteurs DIP du contr le...

Page 32: ...ence Moteur vitesse variable ECM Si le moteur de soufflerie ECM s av re d fectueux et qu un rechange n est pas disponible imm diatement vous pouvez remplacer temporairement le moteur de la soufflerie...

Page 33: ...dans le tuyau de raccordement environ 18 pouces de la bride d vacuation de la fournaise Pour les installations avec une vacuation murale utiliser l orifice pr vu cet effet 2 Suite un d part froid lais...

Page 34: ...azout accumul des vapeurs de mazout ou que la chambre combustion est tr s chaude 4 ENTRETIEN MISE EN GARDE Risque de d charge lectrique Avant d effectuer des travaux d entretien FERMER l alimentation...

Page 35: ...rupteur thermique Un interrupteur thermique endommag doit tre remplac 6 Nettoyer et enlever toute accumulation de salet ou obstruction de l int rieur du tube de transfert de chaleur 7 Remonter verroui...

Page 36: ...dresse du technicien de service R SULTAT DU TEST DE MISE EN MARCHE Gicleur Pression lb po2 Ajustements du br leur Bande principale Bande secondaire Position de la t te CO2 Indice de fum e Bacharach Te...

Page 37: ...103 et des lois am ricaines 87 5 86 2 87 5 86 2 Volts Hertz Phase Consommation Amp Amp minimum pour grosseur du fil Amp Fusible max Amp Contr le du transformateur VA Courant disponible contr les exter...

Page 38: ...n Niveau PCM Temps D lai Off Niveau PCM Temps A 1 OFF 2 OFF 0 90 13 45 sec 44 30 sec 38 3 min B 1 ON 2 OFF 1 10 13 30 sec 44 30 sec 38 3 min C 1 OFF 2 ON 1 10 13 30 sec 50 30 sec 38 3 min D 1 ON 2 ON...

Page 39: ...XTERNE AVEC FILTRE AIR Table 10 D gagement minimum mat riaux combustibles EMPLACEMENT APPLICATION D GAGEMENTS mat riaux combustibles ACC S RECOMMAND POUR L ENTRETIEN FOURNAISE 2 54 cm 1 0 6 m 24 PL NU...

Page 40: ...18 Figure 7 Dimensions de la fournaise...

Page 41: ...____________________________________________________________________________________ 19 Figure 8 Diagramme lectrique Moteur 4 vitesses PSC...

Page 42: ...20 Figure 9 Diagramme lectrique Moteur vitesse variable ECM...

Page 43: ...____________________________________________________________________________________ 21 Figure 10 Liste de pi ces Avec moteur 4 vitesses PSC B50095B...

Page 44: ...DELLE ZINC 1 7 16 34 Z99F061 OEIL DE REGARD POUR CHANGEUR 35 Z06G001 DISPOSITIF D ARR T BVSO 225 36 B03675 GARNITURE SORTIE FUM E 37 B03765 ASS BRIDE DE NETTOYAGE Comprend item 36 38 B03762 ASS COUVER...

Page 45: ...____________________________________________________________________________________ 23 Figure 11 Liste de pi ces Avec moteur vitesse variable ECM B50096C...

Page 46: ...ITE LECTRIQUE Panneau seulement 32 B03118 01 KIT LECTRIQUE BVSO EXT RIEUR 33 F06F015 RONDELLE ZINC 1 7 16 34 Z99F061 OEIL DE REGARD POUR CHANGEUR 35 Z06G001 DISPOSITIF D ARR T BVSO 225 36 B03675 GARNI...

Reviews: