Dettson KLAVT0101DET Installation Instructions And Homeowner'S Manual Download Page 4

 

4

Refer to Table 2 for the minimum and maximum dimensions 
of the vent pipe. 
 
2.2 

POSITIONING 

 

 

WARNING 

 

Poisonous carbon monoxide gas hazard. 

 

Even though the flexible venting is insulated, it must not 
be run through an unheated space. 

 

To  do  so  can  cause  residual  condensation  inside  the 
stainless  steel  liner.  This  may  eventually  perforate  the 
liner  and  allow  vent  gasses  to  enter  the  dwelling, 
potentially  resulting  in  death,  personal  injury  and/or, 
property damage. 

 

 

Important  :  The  minimum  clearance  of  the  vent  pipe  in 
relation  to  combustible  material  is  specified  in  Table  1 
below. This clearance must be maintained all along the pipe. 

 

Table 1 : Minimum clearance around a vent system 

PORTION OF VENT 

CANADA AND 

UNITED STATES 

Vent pipe, up to vent terminal* 

3" (7,62 cm) 

Vent terminal 

Zero 

 

*  Do not enclose venting. 

 

 

 

WARNING 

 

Do not enclose the vent pipe in a ceiling or combustible 
structure. 

 

 

Table 2 : Maximum and minimum vent pipe length 

  MODEL 

VENT PIPE  

INSIDE. DIA. 

MAX. 

LENGTH 

VENT PIPE 

MIN. 

LENGTH 

VENT PIPE 

VTK-53A & VTK1 

7,62

 

cm (3") 

6,10 m (20') 

,91 m (3') 

VTK-64A & VTK2 

10,16 cm (4") 

6,10 m (20') 

,91 m (3') 

VTK-65A, VTK3   

& KLAVT0201DET 

12,70 cm (5") 

6,10 m (20') 

,91 m (3') 

VTK-54A, VTK098 

& KLAVT0101DET 

10,16 cm (4") 

6,10 m (20') 

,91 m (3') 

 

The  interior  portion  of the vent terminal must be installed in 
an area where the temperature of the ambient and return air 
is  higher  than  60°F

 

(15°C).  In  addition,  the  furnace  should 

be  located  as  closely  as  possible  to  the  vent  terminal,  so 
that the ducts are as short and direct as possible. 
 
2.2.1 

Installation considerations 

 
The  vent  may  be  installed  through  a  wall  with  a  minimum 
thickness  of  2"  (5,08  cm)  and  a  maximum  thickness  of  15" 
(38,10  cm).  Select  a  location  for  the  vent  terminal  in 
accordance  with  all  local  and  national  codes.  The  following 
requirements  shall  be  considered  to  be  minimum 
requirements  that  can  be  overridden  by  stricter  local  and 
national codes. 
 
 
  
 

Figure 1 : Minimum clearance 

 

 

CAUTION 

 

Ensure  that  the  area  around  the  side  wall  venter  is 
always  free  of  snow,  ice  and  debris,  since  these  will 
hamper the proper functioning of the furnace. 

 

 
The vent shall not terminate: 
 
a.  Directly above a paved sidewalk or paved driveway that 

is  located  between  two  buildings,  and  that  serves  both 
buildings; 

b.  Less than 7' (2.13 m) above any paved driveway; 

c. 

Within  6'  (1.82  m)  (in  Canada)  of  a  window  or  door,  or 
mechanical air supply inlet to any building;

d.  Within 6' (1.82 m) (in Canada) from the soffit of the roof 

of the structure;* 

e.  Above  a  gas  meter/regulator  assembly  within  3'  (0.91 

m) of a vertical centreline of the regulator; 

f. 

Within  6'  (1.82  m)  of  any  gas  service  regulator  vent 
outlet, or within 3' (0.91 m) of an oil tank vent, or an oil 
fill inlet; 

g.  Within less than 1' (0.30 m) above ground level; 

 

Note  :  The  vent  must be located at least 1' higher than the 
highest anticipated accumulation of snow. 

 

h.  Within 6' (1.82 m) of any other combustion air inlet; 

 

Note  :  It  is  possible  that,  when  the  system  in  not  in 
operation, combustion products may reach the interior of the 
building. 

 

i. 

Within 6' (1.82 m) of a property line; 

j. 

Underneath a veranda, porch or deck; 

k. 

So  that  the  flue  gasses  are  directed  at  combustible 
material  or  any  openings  of  surrounding  buildings  that 
are within 6' (1.82 m); 

Summary of Contents for KLAVT0101DET

Page 1: ...inted in Canada Printed on 100 recycled paper INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR...

Page 2: ...TALLATION OF THE BVSO JUMPER 9 3 0 OPERATION 9 3 1 COMBUSTION GAS TEMPERATURE VERIFICATION 9 3 2 BURNER POST PURGE DELAY ADJUSTMENT 9 4 0 MAINTENANCE 9 FIGURES Figure 1 Minimum clearance 4 Figure 2 Co...

Page 3: ...t with water c Do not store gasoline or any other flammable substances such as paper carton etc near the furnace IMPORTANT All local and national code requirements governing the installation of oil bu...

Page 4: ...e 2 2 1 Installation considerations The vent may be installed through a wall with a minimum thickness of 2 5 08 cm and a maximum thickness of 15 38 10 cm Select a location for the vent terminal in acc...

Page 5: ...Installing the terminal in the wall 1 Open up a 6 15 24 cm hole for the VTK 53A VTK1 VTK 54A VTK098 KLAVT0101DET and VTK 64A VTK2 terminals and a 6 15 88 cm hole for the VTK 65A VTK3 KLAVT0201DET ter...

Page 6: ...secure the back of the shroud to the wall Do not over tighten the screws or it will distort the stabiliser shroud The screws will not be necessary on a concrete or block wall as the mortar can provid...

Page 7: ...ce on the furnace breech plate 5 The installation of the transition must be such that the port for pressure measurements is at the top and accessible once the installation is completed Do not install...

Page 8: ...ransition bushings to go from PVC or ABS to ASTM D 2729 Septic Sewer Pipe if applicable If PVC fittings are mixed with ABS fittings use solvent cement that is approved for bonding the two plastics 2 4...

Page 9: ...93 C 200 F In case it is impossible to obtain this temperature after 5 minutes of operation it is recommended to relocate the furnace in order to shorten the length of the vent pipe After the modific...

Page 10: ...BF3 VTK 53A IFV 310A IFV 315A IFV 320A OHB64F AFII 150 R40 BF5 VTK 64A IFV 410A IFV 415A IFV 420A OLB53F AFII 85 R40 BF3 VTK 53A IFV 310A IFV 315A IFV 320A OLB53R AFII 85 R40 BF3 VTK 53A IFV 310A IFV...

Page 11: ...11 Figure 12 Dimensions Figure 13 Wiring Diagram...

Page 12: ...minal B03906 01 B03906 02 B03906 02 B03906 03 7 Pressure Gauge R99F033 R99F032 R99F032 R99F034 8 Connector with Port B03907 01 B03907 02 B03907 03 B03907 04 9A Insulated Flex Vent 10 long IFV 310A IFV...

Reviews: