background image

1

SAFETY

1.1

SAFETY LABELING AND
WARNING SIGNS

The

words

DANGER,

WARNING

and

CAUTION

are

used

to

identify

the

levels

of

seriousness

of

certain

hazards.

It

is

important

that

you

understand

their

meaning.

You

will

notice

these

words

in

the

manual

as

follows:

DANGER

Immediate hazards which WILL result in death or
serious bodily and/or material damage.

WARNING

Hazards or unsafe practices which CAN result in
death or serious bodily and /or material damage.

CAUTION

Hazards or unsafe practices which CAN result in
minor bodily and /or material damage.

1.2

IMPORTANT INFORMATION

WARNING

Non-observance

of

the

safety

regulations

outlined in this manual will potentially lead to
consequences resulting in death, serious bodily
injury and/or property damage.

WARNING

Installation and repairs performed by unqualified
persons can result in hazards to them and to
others. Installations must conform to local codes
or, in the absence of such codes, to codes of the
country having jurisdiction.
The information contained in this manual is
intended for use by a qualified technician, familiar
with safety procedures and who is equipped with
the proper tools and test instruments.
Failure to carefully read and follow all instructions
in this manual can result in death, bodily injury
and/or property damage.

1. It is the homeowner’s responsibility to engage

a qualified technician for the installation and
subsequent servicing of this furnace;

2. Do not use this furnace if any part of it was

under water.

Call a qualified service technician

immediately to assess the damage and to replace
all critical parts that were in contact with water;

3. Do not store gasoline or any other flammable

substances, such as paper or carton, near the
furnace;

4. Do not stack items or boxing within the required

clearances to combustible materials specified in
Table 2;

5. Never block or otherwise obstruct the filter and/or

return air openings;

6. Ask the technician installing your furnace to show

and explain to you the following items:

• The main disconnect switch or circuit breaker;
• The gas shut off valve;
• The air filter and how to change it (at least

twice a year);

7. Before calling for service, be sure to have the

information of section 11 of your manual close by in
order to be able to provide the contractor with the
required information, such as the model and serial
numbers of the furnace.

WARNING

Failure to follow this warning could result in
dangerous operation,

personal injury,

death,

or property dammage.

Improper installation,

adjustement, servicing or repair can cause carbon
monoxide poisoning, explosion, fire, electrical
shock, or other conditions which may cause
personal injury or property damage.

Consult a

qualified service agency, local gas supplier, or
your distributor for information or assistance. The
qualified service agency must use only factory
authorized and listed kits or accessories when
modifying this product.

WARNING

INJURY HAZARD
Ignoring this warning could result in personal
injury.
Sheet metal parts may have sharp edges or burrs.
Use care and wear appropriate protective clothing,
safety glasses and gloves when handling parts,
and servicing furnaces

1.3

SAFETY CONSIDERATION

Untrained personnel can perform basic maintenance
functions such as cleaning and replacing air filters. All

4

Summary of Contents for CC15-M-V

Page 1: ...future reference Caution Do not tamper with the unit or its controls Call a qualified service technician HOMEOWNER Please keep this manual near the furnace for future reference Manufactured by Dettson...

Page 2: ...1 NON COMMUNICATING MODULATING ONE STAGE OR TWO STAGE THERMOSTAT 16 7 3 2 THERMOSTAT INPUT 16 7 4 ALTERNATE POWER SUPPLY 17 8 VENTING AND COMBUSTION AIR PIPING 19 8 1 GENERAL 19 8 2 DIRECT VENT 19 8 3...

Page 3: ...Alternate horizontal termination A 22 Figure 23 Alternate horizontal termination B 22 Figure 24 Alternate horizontal termination C 22 Figure 25 Direct vent clearance 23 Figure 26 Other than Direct ve...

Page 4: ...assess the damage and to replace all critical parts that were in contact with water 3 Do not store gasoline or any other flammable substances such as paper or carton near the furnace 4 Do not stack it...

Page 5: ...o be handled by duct s sealed to the furnace casing and terminating outside the space containing the furnace See section 5 DUCT INSTALLATION This furnace may be installed with a two pipe sealed combus...

Page 6: ...th the National Fuel Gas Code ANSI Z223 1 NFPA 54 and or Natural Gas and Propane Installation code CSA B149 1 9 After it has been determined that each appliance connected to the venting system properl...

Page 7: ...n Code NSCNGPIC CAN CSA B149 1 General installation NFGC and the NFPA 90B For copies contact the National Fire Protection Association Inc Battery march Park Quincy MA 02269 or for only the NFGC contac...

Page 8: ...in this manual The furnace should be located as close to the chimney vertical venting or to the outside vent wall horizontal venting as possible 2 3 1 Location relative to cooling equipement The cooli...

Page 9: ...on Figure 3 Dimensions Figure 4 Top view Figure 5 Drain Trap Localisation Figure 6 Pressure switch connections for multipositions 4 1 UPFLOW The condensate trap must be outside the furnace casing Use...

Page 10: ...gths 1 4 5 and 2 9 25 3 Remove the appropriate knock out for drain trap Refer to Figure 5 for the location of the drain trap in downflow configuration 4 Cut open the pressure port located on the conde...

Page 11: ...er to ensure proper drainage of the condensate See figure 12 4 3 1 Horizontal Condensate drain connection 1 Remove PVC tubes from the ID blower condensate box and vent collector and block the openings...

Page 12: ...ith local building codes 12 The venting must be drained using a PVC 636 tee Connect this tee to a P trap and connect it to your condensate drain Commercially available condensate trap exist for use wi...

Page 13: ...fasteners for type of ductwork used Seal supply and return duct connections to the furnace with code approved tape or duct sealer Ductwork passing through an unconditioned space should be insulated t...

Page 14: ...ot have a 90 degree elbow and 10 ft 3 M of main duct to the first branch take off may require internal acoustical lining As an alternative fibrous ductwork may be used if constructed and installed in...

Page 15: ...ert the gas valve to propane 1 Move the switch located on the valve to the off position 2 Remove the NAT GAS label from the top of the gas valve 3 Using a pair of tweezers or needle nose pliers place...

Page 16: ...mum mode of operation and will give the best temperature control with minimal temperature variation from the desired set point Operation with a 2 stage thermostat will proceed as follow call on W1 wil...

Page 17: ...te Power from an alternate power supply that is non sinusoidal may damage the furnace electronics or cause erratic operation Contact the alternate power supply manufacturer for specifications and deta...

Page 18: ...Figure 17 Wiring Diagram 18...

Page 19: ...rrent edition of the National Fuel Gas Code and the vent or liner manufacturer s installation instructions Care must be taken to prevent the exhaust gases from one appliance from contaminating the com...

Page 20: ...e 2 Count the number of elbows for each pipe 3 For each pipe multiply the number of elbows by the equivalent length for the type of elbow used see table 11 Record the equivalent length of all the elbo...

Page 21: ...INATION All clearance specified in this manual are in accordance with the current CSA B149 1 Natural and Propane Installation Code and the current ANSI Z223 1 NFPA 54 National Fuel Gas Code For cleara...

Page 22: ...r the elbows to fit on the pipes Holes in the roof for two pipe terminations should be spaced no more than 18 457 mm apart Termination elbows will be installed after the vent and combustion air pipe a...

Page 23: ...Figure 25 Direct vent clearance 23...

Page 24: ...Figure 26 Other than Direct vent clearance 24...

Page 25: ...ve the burner compartment control access door 3 IMPORTANT Be sure that the manual gas control has been in the OFF position for at least five minutes Do not attempt to manually light the main burners 4...

Page 26: ...oth pressure switches quickly Once both pressure switches are sensed to be closed the inducer will run for 25 seconds before the ignition trial starts Hot surface igniter is energized during the pre p...

Page 27: ...esent the furnace will not operate in any mode and a fault will be displayed 9 12 REPLACING FURNACE CONTROL In the event that the furnace control must be replaced the memory card must be detached from...

Page 28: ...r future reference To keep your operating costs low and to eliminate unnecessary service calls we have provided a few guidelines These guidelines will help you understand how your gas furnace operates...

Page 29: ...g 3 Leave the building immediately 4 Immediately call your gas supplier Follow the gas supplier s instructions 5 If you cannot reach the gas supplier call the fire department 10 2 OPERATING YOUR FURNA...

Page 30: ...sense current is weak or weird 1 Clean or replace de flame sensor 2 Check gas outlet pressure 3 Take a combustion analysis A dirty flamme sensor needs to be investigate 13 Flame lost 1 Clean or replac...

Page 31: ...e gas valve will immediately close flame will be lost blower motor operation will immediately stop and the furnace will shut down normally with Inducer post purge at the correct speed After the post p...

Page 32: ...Outlet gas pressure high fire 100 Outlet gas pressure low fire 40 Static pressure in return Static pressure in supply Temperature rise Is drain trap filled with water Is drain trap outlet vented with...

Page 33: ...Table 18 Specification table 1 Maximum CFM acheived in standard duct systems 2 Maximum CFM acheived using SmartDuct system 33...

Page 34: ...12 PART LIST Figure 27 Exploded view...

Page 35: ...Figure 28 Exploded view continued...

Page 36: ...Table 19 Part list Chinook Compact...

Page 37: ...Table 20 Part list continued...

Page 38: ...13 NOTES 38...

Page 39: ...39...

Page 40: ...40...

Reviews: