B
- This terminal is used to pass a reversing valve
signal to a condenser.
It is only a holding place for
connecting a wire from the thermostat and a wire from the
condenser. It does not change the airflow of the cool/heat
commands.
7.4
ALTERNATE POWER SUPPLY
Dettson doesn’t recommend to operate the furnace on a
generator or other alternate power supply. If so it must
produce a smooth sinusoidal waveform for compatibility
with the furnace electronics. The alternate power supply
must generate the same voltage, phase, and frequency
(Hz) as shown on the furnace rating plate.
Power from an alternate power supply that is non-
sinusoidal may damage the furnace electronics or cause
erratic operation.
Contact the alternate power supply manufacturer for
specifications and details.
Table 8 – Electrical Data
Unit size
Volts-Hertz-Phase
Operating
Operating
Maximum
Unit
Maximum fuse
range Min
range Max
unit amp
ampacity
CKT BRK amp
15,000
120-60-1
127
104
10.7
12.6
15
Table 9 – Thermostat Choice VS System
Heating
Cooling
Thermostat
HRV interlock
Interface
Smart Duct
system
system
at low CFM
board needed
compliant
Modulating
Alizé
Communicating
Yes
Yes
Yes
chinook
R02P032
Modulating
1 stage Non-Alizé
Communicating
Yes
Yes
No
chinook
Cooling unit
R02P032
Modulating
1&2 stage Non-Alizé
2-Stage
No
No
No
chinook
Cooling unit/Heat pump
R02P032
17
Summary of Contents for CC15-M-V
Page 18: ...Figure 17 Wiring Diagram 18...
Page 23: ...Figure 25 Direct vent clearance 23...
Page 24: ...Figure 26 Other than Direct vent clearance 24...
Page 34: ...12 PART LIST Figure 27 Exploded view...
Page 35: ...Figure 28 Exploded view continued...
Page 36: ...Table 19 Part list Chinook Compact...
Page 37: ...Table 20 Part list continued...
Page 38: ...13 NOTES 38...
Page 39: ...39...
Page 40: ...40...