background image

4) 

Insert the motor into the female support and secure with the screw.

 

5) 

Secure locking screw on FEMALE SUPPORTER for desired head angle / tilt. To 

adjust the head tilt, loosen the nut above the female support, then re-secure the nut after 
adjustment.

WARNING! Make sure all parts are assembled correctly and connections are tight. 
WARNING! If supply cable to too tight the oscillating motion can cause damage - ensure 
sufficient section of cable to avoid damage.

ENVIRONMENT OF USE

1)  The max relative humidity is 90%(when in 25

)

2)  Below 1000 metres altitude.

OPERATION

1)  Make sure the Fans voltage is in accordance with local voltage before use.

2)  The fan is recommended for use in ordinary indoor situations, but not at high humidity.

3)   To turn on select the desired speed setting

 

 

0   - Off

 

 

1   - Slow

 

 

- Medium

 

 

- Fast

4)    For fixed air flow ensure the swing arm is not connected to the fan motor

5)   For oscillating air flow ensure the swing arm is connected to the fan motor by rotating 
the oscillating adjustment screw in an anti-clockwise direction.

6)   Unplug the fan when not in use.

WALL FAN ASSEMBLY CONTINUED

PAGE 6

PAGE 7

 

FIG 4

 – The fan head in the OSCILLATION 

posi

ti

on. Oscilla

ti

on is 0-90

°.

 

FIG 3

 – For an OSCILLATING fan head, turn the 

OSCILLATING ADJUSTMENT screw an

ti

clockwise 

to a

tt

ach SWING ARM to fan head 

FIG 1

 – The fan switch on the OFF posi

ti

on 

FIG 2

 – The fan head in the FIXED air 

ow 

posi

ti

on 

SWING ARM  

MAINTENANCE

3)  To ensure prolonged safe use ensure you have this unit inpected, cleaned & moving 
parts lubricated by a qualified person after every 1000 hours of use.

4)  Regularly inspect the cord & plug & do not use if damaged. A lisenced electrician is 
required to repair or replace the cord & plug. 

5)  Any other repairs or maintenance must be performed by a qualified person.

LOCATING SCREW

FEMALE SUPPORTER

FAN HEAD

Summary of Contents for DFS75

Page 1: ...or failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty claims To make a claim under this warranty you must bring the product along with the proof of purchase and any other documentary evidence which you t...

Page 2: ... with a damaged cord or plug after the product malfunctions is dropped or appears damaged in any way Return the complete product to the place of purchase for inspection repair or replacement To reduce the risk of electric shock do not immerse or expose the product or flexible cord to rain moisture or any liquid This product should not be used in the immediate vicinity of water such as sinks bathtu...

Page 3: ... 1 12 Plate color zinc 11 GB52 76 Hex nut 1 M12X40 Plate color zinc 12 GB30 76 Hex bolt 1 M12X40 Plate color zinc 15 FB FB 65 011 000 010 Motor assembled indication 1 2M Cord 16 FS FB 65 011 070 000 Fit washer 4 D15 d6 5 h1 5 Plate color zinc 17 GB593 85 Spring washer 4 6 Plate color zinc 18 GB818 85 Cross screw 4 M6X16 Plate color zinc 19 FS FB 65 030 000 000 Fan blade 1 Spray coating 20 FS FB 65...

Page 4: ...3 4 18 17 16 Serial No Item No Des QTY Spec Material Remark 1 FS 75 050 000 000 Cross base 1 600 HT100 Spray coating 2 FS 75 040 030 000 Washer 1 D60 d12 5 3 Plate color zinc 3 GB593 85 Spring washer 1 12 Plate color zinc 4 GB5780 86 Hex bolt 1 M12X40 Spray coating 5 FS 75 040 000 000 Supporting tube 1 Plate color zinc 6 GB818 85 Cross screw 1 M6X12 Spray coating 7 FS FB 75 040 040 000 Under conne...

Page 5: ...g the two screws provided NOTE The Bend tube can be positioned either upwards or downwards You must orient female support upward by removing the screw repositioning resecuring Never attach the fan so it is hanging below the female supporter PAGE 8 PAGE 5 WALL FAN ASSEMBLY ELECTRICAL DIAGRAM SPECIFICATIONS FRONT VIEW Model Description Size mm Volt V Freq Hz Watts W Air Flow m3 min DFS75 Pedestal Fa...

Page 6: ...4 For fixed air flow ensure the swing arm is not connected to the fan motor 5 For oscillating air flow ensure the swing arm is connected to the fan motor by rotating the oscillating adjustment screw in an anti clockwise direction 6 Unplug the fan when not in use WALL FAN ASSEMBLY CONTINUED PAGE 6 PAGE 7 FIG 4 The fan head in the OSCILLATION position Oscillation is 0 90 FIG 3 For an OSCILLATING fan...

Reviews: