SERIES 60 EGR TECHNICIAN'S MANUAL
VPOD Output Pressure Test
Test steps are as follows:
1. Disconnect the air hose from the VNT actuator. See Figure 10-1.
Figure 10-1
Location of Venturi Tube Hoses
2. Install gage at the outlet of the VNT air line. See Figure 10-2.
NOTE:
The gage should be accurate to within 1.4 kPa (0.2 psi).