![Detex VALUE SERIES EH Installation Instructions Manual Download Page 9](http://html.mh-extra.com/html/detex/value-series-eh/value-series-eh_installation-instructions-manual_2487942009.webp)
101275 Page 9
extend its life.
Care and Maintenance:
The Detex Value Series® devices are designed to provide many years of maintenance
free service under normal usage. Periodically inspect and lubricate the unit to
with hand tools only.
Install cover with 6-32
machine screws. Tighten
4
Fasten rim device to mounting
plate and door with 1/4-20x1"
machine screws(drill #7 holes)
or #14 self-drilling screws
center screw.
strike engagement BEFORE
Align the 99 strike with
Firmly tighten screws
the latchbolt.
marking and drilling for
Check device function and
(use shim if necessary)
3
Note:
2
Mark and drill center hole.
9/64" for 10-24 machine
screws.
No pilot hole necessary
for #10 self-drilling screws.
(see fastener table)
Secure the 99 strike.
Deadlatch
99 strike
For Hurricane Models
(see Hurricane kit)
1